Literature DB >> 16060516

Design and fabrication of a 40-MHz annular array transducer.

Jeffrey A Ketterling1, Orlando Aristizábal, Daniel H Turnbull, Frederic L Lizzi.   

Abstract

This paper investigates the feasibility of fabricating a five-ring, focused annular array transducer operating at 40 MHz. The active piezoelectric material of the transducer was a 9-microm thick polyvinylidene fluoride (PVDF) film. One side of the PVDF was metallized with gold and forms the ground plane of the transducer. The array pattern of the transducer and electrical traces to each annulus were formed on a copper-clad polyimide film. The PVDF and polyimide were bonded with a thin layer of epoxy, pressed into a spherically curved shape, then back filled with epoxy. A five-ring transducer with equal area elements and 100-microm kerfs between annuli was fabricated and tested. The transducer had a total aperture of 6 mm and a geometric focus of 12 mm. The pulse/echo response from a quartz plate located at the geometric focus, two-way insertion loss (IL), complex impedance, electrical crosstalk, and lateral beamwidth all were measured for each annulus. The complex impedance data from each element were used to perform electrical matching, and the measurements were repeated. After impedance matching; fc approximately equal to 36 MHz and -6-dB bandwidths ranged from 31 to 39%. The ILs for the matched annuli ranged from -28 to -38 dB.

Entities:  

Year:  2005        PMID: 16060516      PMCID: PMC1351293          DOI: 10.1109/tuffc.2005.1428050

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  19 in total

Review 1.  Advances in ultrasound biomicroscopy.

Authors:  F S Foster; C J Pavlin; K A Harasiewicz; D A Christopher; D H Turnbull
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

2.  A low-cost, high-performance pulse generator for ultrasound imaging.

Authors:  Jeremy A Brown; Geoffrey R Lockwood
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-06       Impact factor: 2.725

Review 3.  Ultrasound biomicroscopy-Doppler in mouse cardiovascular development.

Authors:  Colin K L Phoon; Daniel H Turnbull
Journal:  Physiol Genomics       Date:  2003-06-24       Impact factor: 3.107

4.  Design and fabrication of annular arrays for high-frequency ultrasound.

Authors:  Jeremy A Brown; Christine E M Démoré; Geoffrey R Lockwood
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-08       Impact factor: 2.725

5.  The design of protection circuitry for high-frequency ultrasound imaging systems.

Authors:  G R Lockwood; J W Hunt; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

6.  Design considerations for piezoelectric polymer ultrasound transducers.

Authors:  L F Brown
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

7.  An annular array system for high resolution breast echography.

Authors:  M Arditi; W B Taylor; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1982-01       Impact factor: 1.578

8.  The design and fabrication of high frequency poly(vinylidene fluoride) transducers.

Authors:  M D Sherar; F S Foster
Journal:  Ultrason Imaging       Date:  1989-04       Impact factor: 1.578

9.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

10.  44-MHz LiNbO3 transducers for UBM-guided Doppler ultrasound.

Authors:  Orlando Aristizábal; Daniel H Turnbull
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-06       Impact factor: 2.725

View more
  33 in total

1.  40-MHz annular array imaging of mouse embryos.

Authors:  Orlando Aristizábal; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

2.  Chirp-coded excitation imaging with a high-frequency ultrasound annular array.

Authors:  Jonathan Mamou; Jeffrey A Ketterling; Ronald H Silverman
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-02       Impact factor: 2.725

3.  Improved high-resolution ultrasonic imaging of the eye.

Authors:  Ronald H Silverman; Jeffrey A Ketterling; Jonathan Mamou; D Jackson Coleman
Journal:  Arch Ophthalmol       Date:  2008-01

4.  Beamwidth measurement of individual lithotripter shock waves.

Authors:  Wayne Kreider; Michael R Bailey; Jeffrey A Ketterling
Journal:  J Acoust Soc Am       Date:  2009-02       Impact factor: 1.840

5.  40-MHz ultrasound imaging with chirps and annular arrays.

Authors:  Jonathan Mamou; Orlando Aristizábal; Ronald H Silverman; Jeffrey A Ketterling
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

6.  High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging.

Authors:  Erwan Filoux; Ashwin Sampathkumar; Parag V Chitnis; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  Rev Sci Instrum       Date:  2013-05       Impact factor: 1.523

7.  Single-shot measurements of the acoustic field of an electrohydraulic lithotripter using a hydrophone array.

Authors:  Mohammad A Alibakhshi; Jonathan M Kracht; Robin O Cleveland; Erwan Filoux; Jeffrey A Ketterling
Journal:  J Acoust Soc Am       Date:  2013-05       Impact factor: 1.840

8.  Piezoelectric films for high frequency ultrasonic transducers in biomedical applications.

Authors:  Qifa Zhou; Sienting Lau; Dawei Wu; K Kirk Shung
Journal:  Prog Mater Sci       Date:  2011-02

9.  Correspondence - Characterization of the effective performance of a high-frequency annular-array-based imaging system using anechoic-pipe phantoms.

Authors:  Erwan Filoux; Jonathan Mamou; Carmel M Moran; Stephen D Pye; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-12       Impact factor: 2.725

10.  High Frequency Ultrasonic Imaging.

Authors:  K Kirk Shung
Journal:  J Med Ultrasound       Date:  2009
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.