Literature DB >> 14682638

Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Jonathan M Cannata1, Timothy A Ritter, Wo-Hsing Chen, Ronald H Silverman, K Kirk Shung.   

Abstract

This paper discusses the design, fabrication, and testing of sensitive broadband lithium niobate (LiNbO3) single-element ultrasonic transducers in the 20-80 MHz frequency range. Transducers of varying dimensions were built for an f# range of 2.0-3.1. The desired focal depths were achieved by either casting an acoustic lens on the transducer face or press-focusing the piezoelectric into a spherical curvature. For designs that required electrical impedance matching, a low impedance transmission line coaxial cable was used. All transducers were tested in a pulse-echo arrangement, whereby the center frequency, bandwidth, insertion loss, and focal depth were measured. Several transducers were fabricated with center frequencies in the 20-80 MHz range with the measured -6 dB bandwidths and two-way insertion loss values ranging from 57 to 74% and 9.6 to 21.3 dB, respectively. Both transducer focusing techniques proved successful in producing highly sensitive, high-frequency, single-element, ultrasonic-imaging transducers. In vivo and in vitro ultrasonic backscatter microscope (UBM) images of human eyes were obtained with the 50 MHz transducers. The high sensitivity of these devices could possibly allow for an increase in depth of penetration, higher image signal-to-noise ratio (SNR), and improved image contrast at high frequencies when compared to previously reported results.

Entities:  

Mesh:

Year:  2003        PMID: 14682638     DOI: 10.1109/tuffc.2003.1251138

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  73 in total

1.  High-resolution coregistered intravascular imaging with integrated ultrasound and optical coherence tomography probe.

Authors:  Xiang Li; Jiechen Yin; Changhong Hu; Qifa Zhou; K Kirk Shung; Zhongping Chen
Journal:  Appl Phys Lett       Date:  2010-09-27       Impact factor: 3.791

2.  Multimodal characterization of compositional, structural and functional features of human atherosclerotic plaques.

Authors:  Yang Sun; Abhijit J Chaudhari; Matthew Lam; Hongtao Xie; Diego R Yankelevich; Jennifer Phipps; Jing Liu; Michael C Fishbein; Jonathan M Cannata; K Kirk Shung; Laura Marcu
Journal:  Biomed Opt Express       Date:  2011-07-19       Impact factor: 3.732

3.  Design of matching layers for high-frequency ultrasonic transducers.

Authors:  Chunlong Fei; Jianguo Ma; Chi Tat Chiu; Jay A Williams; Wayne Fong; Zeyu Chen; BenPeng Zhu; Rui Xiong; Jing Shi; Tzung K Hsiai; K Kirk Shung; Qifa Zhou
Journal:  Appl Phys Lett       Date:  2015-09-24       Impact factor: 3.791

4.  75 MHz ultrasound biomicroscopy of anterior segment of eye.

Authors:  Ronald H Silverman; Jonathan Cannata; K Kirk Shung; Omer Gal; Monica Patel; Harriet O Lloyd; Ernest J Feleppa; D Jackson Coleman
Journal:  Ultrason Imaging       Date:  2006-07       Impact factor: 1.578

5.  Design and fabrication of broadband graded ultrasonic transducers with rectangular kerfs.

Authors:  Hongkai Guo; Jonathan M Cannata; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-11       Impact factor: 2.725

6.  High-frequency harmonic imaging of the eye.

Authors:  Ronald H Silverman; D Jackson Coleman; Jeffrey A Ketterling; Frederic L Lizzi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

7.  In vivo cardiac imaging of adult zebrafish using high frequency ultrasound (45-75 MHz).

Authors:  Lei Sun; Ching-Ling Lien; Xiaochen Xu; K Kirk Shung
Journal:  Ultrasound Med Biol       Date:  2007-09-07       Impact factor: 2.998

8.  High frequency photoacoustic imaging for in vivo visualizing blood flow of zebrafish heart.

Authors:  Jinhyoung Park; Thomas M Cummins; Michael Harrison; Jungwoo Lee; Qifa Zhou; Ching-Ling Lien; K Kirk Shung
Journal:  Opt Express       Date:  2013-06-17       Impact factor: 3.894

9.  Transparent High-Frequency Ultrasonic Transducer for Photoacoustic Microscopy Application.

Authors:  Ruimin Chen; Yun He; Junhui Shi; Christopher Yung; Jeeseong Hwang; Lihong V Wang; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-03       Impact factor: 2.725

10.  Design and fabrication of a 40-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal; Daniel H Turnbull; Frederic L Lizzi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-04       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.