Literature DB >> 23742556

High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging.

Erwan Filoux1, Ashwin Sampathkumar, Parag V Chitnis, Orlando Aristizábal, Jeffrey A Ketterling.   

Abstract

This paper presents a combined ultrasound and photoacoustic (PA) imaging (PAI) system used to obtain high-quality, co-registered images of mouse-embryo anatomy and vasculature. High-frequency ultrasound (HFU, >20 MHz) is utilized to obtain high-resolution anatomical images of small animals while PAI provides high-contrast images of the vascular network. The imaging system is based on a 40 MHz, 5-element, 6 mm aperture annular-array transducer with a 800 μm diameter hole through its central element. The transducer was integrated in a cage-plate assembly allowing for a collimated laser beam to pass through the hole so that the optical and acoustic beams were collinear. The assembly was mounted on a two-axis, motorized stage to enable the simultaneous acquisition of co-registered HFU and PA volumetric data. Data were collected from all five elements in receive and a synthetic-focusing algorithm was applied in post-processing to beamform the data and increase the spatial resolution and depth-of-field (DOF) of the HFU and PA images. Phantom measurements showed that the system could achieve high-resolution images (down to 90 μm for HFU and 150 μm for PAI) and a large DOF of >8 mm. Volume renderings of a mouse embryo showed that the scanner allowed for visualizing morphologically precise anatomy of the entire embryo along with corresponding co-registered vasculature. Major head vessels, such as the superior sagittal sinus or rostral vein, were clearly identified as well as limb bud vasculature.

Entities:  

Mesh:

Year:  2013        PMID: 23742556      PMCID: PMC3676372          DOI: 10.1063/1.4804636

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  22 in total

1.  k-space propagation models for acoustically heterogeneous media: application to biomedical photoacoustics.

Authors:  B T Cox; S Kara; S R Arridge; P C Beard
Journal:  J Acoust Soc Am       Date:  2007-06       Impact factor: 1.840

2.  Design considerations for piezoelectric polymer ultrasound transducers.

Authors:  L F Brown
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

3.  Noninvasive photoacoustic imaging of the developing vasculature during early tumor growth.

Authors:  Yeqi Lao; Da Xing; Sihua Yang; Liangzhong Xiang
Journal:  Phys Med Biol       Date:  2008-07-17       Impact factor: 3.609

4.  In vivo imaging and characterization of hypoxia-induced neovascularization and tumor invasion.

Authors:  Gina F Lungu; Meng-Lin Li; Xueyi Xie; Lihong V Wang; George Stoica
Journal:  Int J Oncol       Date:  2007-01       Impact factor: 5.650

5.  An annular array system for high resolution breast echography.

Authors:  M Arditi; W B Taylor; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1982-01       Impact factor: 1.578

6.  Alteration of limb and brain patterning in early mouse embryos by ultrasound-guided injection of Shh-expressing cells.

Authors:  A Liu; A L Joyner; D H Turnbull
Journal:  Mech Dev       Date:  1998-07       Impact factor: 1.882

Review 7.  Mouse models of human disease. Part I: techniques and resources for genetic analysis in mice.

Authors:  M A Bedell; N A Jenkins; N G Copeland
Journal:  Genes Dev       Date:  1997-01-01       Impact factor: 11.361

8.  Doppler-derived trigger signals for high-frame-rate mouse cardiovascular imaging.

Authors:  Orlando Aristizabal; Jonathan Mamou; Daniel H Turnbull; Jeffrey A Ketterling
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

Review 9.  Genetically engineered mouse models of neurodegenerative diseases.

Authors:  Philip C Wong; Huaibin Cai; David R Borchelt; Donald L Price
Journal:  Nat Neurosci       Date:  2002-07       Impact factor: 24.884

10.  In vivo photoacoustic imaging of mouse embryos.

Authors:  Jan Laufer; Francesca Norris; Jon Cleary; Edward Zhang; Bradley Treeby; Ben Cox; Peter Johnson; Pete Scambler; Mark Lythgoe; Paul Beard
Journal:  J Biomed Opt       Date:  2012-06       Impact factor: 3.170

View more
  4 in total

1.  Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer.

Authors:  Parag V Chitnis; Orlando Aristizábal; Erwan Filoux; Ashwin Sampathkumar; Jonathan Mamou; Jeffrey A Ketterling
Journal:  Ultrason Imaging       Date:  2015-04-28       Impact factor: 1.578

2.  Fiber-optic annular detector array for large depth of field photoacoustic macroscopy.

Authors:  Johannes Bauer-Marschallinger; Astrid Höllinger; Bernhard Jakoby; Peter Burgholzer; Thomas Berer
Journal:  Photoacoustics       Date:  2017-01-25

Review 3.  Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment.

Authors:  Jorge Palma-Chavez; T Joshua Pfefer; Anant Agrawal; Jesse V Jokerst; William C Vogt
Journal:  J Biomed Opt       Date:  2021-09       Impact factor: 3.170

4.  Non-invasive determination of murine placental and foetal functional parameters with multispectral optoacoustic tomography.

Authors:  Kausik Basak; Xosé Luís Deán-Ben; Sven Gottschalk; Michael Reiss; Daniel Razansky
Journal:  Light Sci Appl       Date:  2019-08-14       Impact factor: 17.782

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.