Literature DB >> 18238684

Design considerations for piezoelectric polymer ultrasound transducers.

L F Brown1.   

Abstract

Much work has been published on the design of ultrasound transducers using piezoelectric ceramics, but a great deal of this work does not apply when using the piezoelectric polymers because of their unique electrical and mechanical properties. The purpose of this paper is to review and present new insight into seven important considerations for the design of active piezoelectric polymer ultrasound transducers: piezoelectric polymer materials selection, transducer construction and packaging requirements, materials characterization and modeling, film thickness and active area design, electroding selection, backing material design, and front protection/matching layer design. Besides reviewing these design considerations, this paper also presents new insight into the design of active piezoelectric polymer ultrasonic transducers. The design and fabrication of an immersible ultrasonic transducer, which has no adhesive layer between the active element and backing layer, is included. The transducer features direct deposition of poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] copolymer onto an insulated aluminum backing substrate. Pulse-echo tests indicated a minimum insertion loss of 37 dB and -6 dB bandwidth of 9.8 to 22 MHz (71%). The use of polymer wear-protection/quarter-wave matching layers is also discussed. Test results on a P(VDF-TrFE) transducer showed that a Mylar/sup TM/ front layer provided a slight increase in pulse-echo amplitude of 15% (or 1.2 dB) and an increase in -6 dB pulse-echo fractional bandwidth from 86 to 95%. Theoretical derivations are reported for optimizing the active area of the piezoelectric polymer element for maximum power transfer at resonance. These derivations are extended to the special case for a low profile (i.e., thin) shielded transducer. A method for modeling the non-linear loading effects of a commercial pulser-receiver is also included.

Entities:  

Year:  2000        PMID: 18238684     DOI: 10.1109/58.883527

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  14 in total

1.  Photoacoustic imaging with a commercial ultrasound system and a custom probe.

Authors:  Xueding Wang; J Brian Fowlkes; Jonathan M Cannata; Changhong Hu; Paul L Carson
Journal:  Ultrasound Med Biol       Date:  2011-01-26       Impact factor: 2.998

2.  High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging.

Authors:  Erwan Filoux; Ashwin Sampathkumar; Parag V Chitnis; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  Rev Sci Instrum       Date:  2013-05       Impact factor: 1.523

3.  Piezoelectric films for high frequency ultrasonic transducers in biomedical applications.

Authors:  Qifa Zhou; Sienting Lau; Dawei Wu; K Kirk Shung
Journal:  Prog Mater Sci       Date:  2011-02

4.  Fabrication and performance of endoscopic ultrasound radial arrays based on PMN-PT single crystal/epoxy 1-3 composite.

Authors:  Dan Zhou; Kwok Fung Cheung; Yan Chen; Sien Ting Lau; Qifa Zhou; K Kirk Shung; Hao Su Luo; Jiyan Dai; Helen Lai Wa Chan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-02       Impact factor: 2.725

5.  Improved fabrication of focused single element P(VDF-TrFE) transducer for high frequency ultrasound applications.

Authors:  Jong Seob Jeong; K Kirk Shung
Journal:  Ultrasonics       Date:  2012-09-06       Impact factor: 2.890

6.  Characterization of the spatial resolution of different high-frequency imaging systems using a novel anechoic-sphere phantom.

Authors:  Erwan Filoux; Jonathan Mamou; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-05       Impact factor: 2.725

7.  Development of a flexible implantable sensor for postoperative monitoring of blood flow.

Authors:  Jonathan M Cannata; Thomas Chilipka; Hao-Chung Yang; Sukgu Han; Sung W Ham; Vincent L Rowe; Fred A Weaver; K Kirk Shung; David Vilkomerson
Journal:  J Ultrasound Med       Date:  2012-11       Impact factor: 2.153

8.  Design and fabrication of a 40-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal; Daniel H Turnbull; Frederic L Lizzi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-04       Impact factor: 2.725

9.  The use of combined thermal/pressure polyvinylidene fluoride film airflow sensor in polysomnography.

Authors:  Meir Kryger; Todd Eiken; Li Qin
Journal:  Sleep Breath       Date:  2013-05-29       Impact factor: 2.816

10.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.