Literature DB >> 18334358

Chirp-coded excitation imaging with a high-frequency ultrasound annular array.

Jonathan Mamou, Jeffrey A Ketterling, Ronald H Silverman.   

Abstract

High-frequency ultrasound (HFU, > 15 MHz) is an effective means of obtaining fine-resolution images of biological tissues for applications such as opthalmologic, dermatologic, and small animal imaging. HFU has two inherent drawbacks. First, HFU images have a limited depth of field (DOF) because of the short wavelength and the low fixed F-number of conventional HFU transducers. Second, HFU can be used to image only a few millimeters deep into a tissue because attenuation increases with frequency. In this study, a five-element annular array was used in conjunction with a synthetic-focusing algorithm to extend the DOF. The annular array had an aperture of 10 mm, a focal length of 31 mm, and a center frequency of 17 MHz. To increase penetration depth, 8-micros, chirp-coded signals were designed, input into an arbitrary waveform generator, and used to excite each array element. After data acquisition, the received signals were linearly filtered to restore axial resolution and increase the SNR. To compare the chirpcoded imaging method with conventional impulse imaging in terms of resolution, a 25-microm diameter wire was scanned and the -6-dB axial and lateral resolutions were computed at depths ranging from 20.5 to 40.5 mm. The results demonstrated that chirp-coded excitation did not degrade axial or lateral resolution. A tissue-mimicking phantom containing 10-microm glass beads was scanned, and backscattered signals were analyzed to evaluate SNR and penetration depth. Finally, ex vivo ophthalmic images were formed and chirpcoded images showed features that were not visible in conventional impulse images.

Entities:  

Mesh:

Year:  2008        PMID: 18334358      PMCID: PMC2652352          DOI: 10.1109/TUFFC.2008.670

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  10 in total

1.  Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation.

Authors:  Vera Behar; Dan Adam
Journal:  Ultrasonics       Date:  2004-08       Impact factor: 2.890

2.  Coded excitation for diagnostic ultrasound: a system developer's perspective.

Authors:  Richard Y Chiao; Xiaohui Hao
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

Review 3.  Use of modulated excitation signals in medical ultrasound. Part I: Basic concepts and expected benefits.

Authors:  Thanassis Misaridis; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

4.  Development and evaluation of a high-frequency ultrasound-based system for in vivo strain imaging of the skin.

Authors:  Michael Vogt; Helmut Ermert
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-03       Impact factor: 2.725

5.  Coded excitation system for improving the penetration of real-time phased-array imaging systems.

Authors:  M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

Review 6.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues.

Authors:  S A Goss; R L Johnston; F Dunn
Journal:  J Acoust Soc Am       Date:  1978-08       Impact factor: 1.840

7.  Three-dimensional high-frequency ultrasonic parameter imaging of anterior segment pathology.

Authors:  R H Silverman; M J Rondeau; F L Lizzi; D J Coleman
Journal:  Ophthalmology       Date:  1995-05       Impact factor: 12.079

8.  An annular array system for high resolution breast echography.

Authors:  M Arditi; W B Taylor; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1982-01       Impact factor: 1.578

9.  Design and fabrication of a 40-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal; Daniel H Turnbull; Frederic L Lizzi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-04       Impact factor: 2.725

10.  Operational verification of a 40-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Sarayu Ramachandran; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-03       Impact factor: 2.725

  10 in total
  14 in total

1.  40-MHz ultrasound imaging with chirps and annular arrays.

Authors:  Jonathan Mamou; Orlando Aristizábal; Ronald H Silverman; Jeffrey A Ketterling
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

2.  Barker-coded excitation in ophthalmological ultrasound imaging.

Authors:  Sheng Zhou; Xiao-Chun Wang; Jun Yang; Jian-Jun Ji; Yan-Qun Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

3.  A Novel Quantitative 500-MHz Acoustic Microscopy System for Ophthalmologic Tissues.

Authors:  Daniel Rohrbach; Anette Jakob; Harriet O Lloyd; Steffen H Tretbar; Ronald H Silverman; Jonathan Mamou
Journal:  IEEE Trans Biomed Eng       Date:  2016-05-26       Impact factor: 4.538

4.  Characterization of the spatial resolution of different high-frequency imaging systems using a novel anechoic-sphere phantom.

Authors:  Erwan Filoux; Jonathan Mamou; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-05       Impact factor: 2.725

5.  Pulse-encoded ultrasound imaging of the vitreous with an annular array.

Authors:  Ronald H Silverman; Jeffrey A Ketterling; Jonathan Mamou; Harriet O Lloyd; Erwan Filoux; D Jackson Coleman
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011-09-08

6.  A high-frequency annular-array transducer using an interdigital bonded 1-3 composite.

Authors:  Hamid Reza Chabok; Jonathan M Cannata; Hyung Ham Kim; Jay A Williams; Jinhyoung Park; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-01       Impact factor: 2.725

7.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

8.  High-frequency chirp ultrasound imaging with an annular array for ophthalmologic and small-animal imaging.

Authors:  Jonathan Mamou; Orlando Aristizábal; Ronald H Silverman; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2009-04-25       Impact factor: 2.998

Review 9.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

10.  Frequency-Dependent Spatial Coherence in Conventional and Chirp Transmissions.

Authors:  James Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.