Progress in medical ultrasound exposimetry.

Gerald R Harris1.   

Abstract

Biomedical applications of ultrasound have experienced tremendous growth over the past 50 years. Early work in thermal therapy and surgery soon was followed by diagnostic imaging and Doppler. Because patient safety was an important issue from the beginning, the study of methods for measuring exposure levels, and their relationship to possible biological effects, paralleled the growth of the various therapeutic and diagnostic techniques. The diverse conditions of use have presented a range of exposure measurement challenges, and the sensors and techniques used to evaluate ultrasound fields have had to evolve as new or expanded clinical applications have emerged. In this paper some of the more notable of these developments are presented and discussed. Topics covered include devices and techniques, methods of calibration, progress in standardization, and current problem areas, including the effects of nonlinear propagation. Some early methods are described, but emphasis is given to more recent work applicable to present and future uses of ultrasound in medicine and biology.

Entities:  

Mesh:

Year:  2005        PMID: 16048175     DOI: 10.1109/tuffc.2005.1503960

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  20 in total

1.  Acoustic holography as a metrological tool for characterizing medical ultrasound sources and fields.

Authors:  Oleg A Sapozhnikov; Sergey A Tsysar; Vera A Khokhlova; Wayne Kreider
Journal:  J Acoust Soc Am       Date:  2015-09       Impact factor: 1.840

2.  Ultrasound field measurement using a binary lens.

Authors:  Gregory Clement; Hideyuki Nomura; Tomoo Kamakura
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

3.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

4.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part II: Experimental Validation of Spatial Averaging Model.

Authors:  Keith A Wear; Yunbo Liu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

5.  Improved measurement of acoustic output using complex deconvolution of hydrophone sensitivity.

Authors:  Keith A Wear; Paul M Gammell; Subha Maruvada; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

6.  Correction for frequency-dependent hydrophone response to nonlinear pressure waves using complex deconvolution and rarefactional filtering: application with fiber optic hydrophones.

Authors:  Keith Wear; Yunbo Liu; Paul M Gammell; Subha Maruvada; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

7.  Characterization of nonlinear ultrasound fields of 2D therapeutic arrays.

Authors:  Petr V Yuldashev; Wayne Kreider; Oleg A Sapozhnikov; Navid Farr; Ari Partanen; Michael R Bailey; Vera Khokhlova
Journal:  IEEE Int Ultrason Symp       Date:  2012-10-07

8.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

Review 9.  Advances in acoustic monitoring and control of focused ultrasound-mediated increases in blood-brain barrier permeability.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Br J Radiol       Date:  2019-02-28       Impact factor: 3.039

Review 10.  Overview of therapeutic ultrasound applications and safety considerations.

Authors:  Douglas L Miller; Nadine B Smith; Michael R Bailey; Gregory J Czarnota; Kullervo Hynynen; Inder Raj S Makin
Journal:  J Ultrasound Med       Date:  2012-04       Impact factor: 2.153