Literature DB >> 16003513

Changes in corneal thickness and curvature after different excimer laser photorefractive procedures and their impact on intraocular pressure measurements.

Helena Svedberg1, Enping Chen, Helene Hamberg-Nyström.   

Abstract

BACKGROUND: Excimer laser refractive surgery alters the shape and thickness of the cornea by removing central corneal tissue with submicrometer precision. The aim of the study was to analyze the changes in central corneal thickness (CCT) and curvature before and after different excimer laser photorefractive procedures and their possible impact on intraocular pressure (IOP) estimations with Goldmann applanation tonometry.
METHODS: Data on CCT, corneal curvature and IOP readings with Goldmann applanation tonometry before and after excimer laser photorefractive surgery were analyzed retrospectively. The data was further analyzed separately in two subgroups; the photorefractive keratectomy /laser-assisted subepithelial keratomileusis (PRK/LASEK) group and the laser in situ keratomileusis (LASIK) group.
RESULTS: The overall post-operative IOP readings were significantly lower than pre-operative values. There was a significant difference in the lowering of the IOP readings between the two subgroups: LASIK caused a lower IOP reading than PRK/LASEK.
CONCLUSION: The change in corneal thickness and curvature affects the estimation of IOP with Goldmann applanation tonometry after excimer laser photorefractive surgery. The amount of reduction in IOP reading might be influenced by the specific laser surgical procedure. This is of clinical importance in the evaluation of any future glaucoma in the increasing number of patients who undergo photorefractive laser surgery.

Entities:  

Mesh:

Year:  2005        PMID: 16003513     DOI: 10.1007/s00417-005-0072-x

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  15 in total

1.  Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.

Authors:  N Feltgen; D Leifert; J Funk
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

2.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

3.  Accuracy and precision of EyeSys and Orbscan systems on calibrated spherical test surfaces.

Authors:  Javier González Pérez; A Cerviño; M J Giraldez; M Parafita; E Yebra-Pimentel
Journal:  Eye Contact Lens       Date:  2004-04       Impact factor: 2.018

4.  Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study.

Authors:  R C Wolfs; C C Klaver; J R Vingerling; D E Grobbee; A Hofman; P T de Jong
Journal:  Am J Ophthalmol       Date:  1997-06       Impact factor: 5.258

5.  Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Correlation with pretreatment myopia.

Authors:  A Chatterjee; S Shah; D A Bessant; S A Naroo; S J Doyle
Journal:  Ophthalmology       Date:  1997-03       Impact factor: 12.079

6.  The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer.

Authors:  P G Mardelli; L W Piebenga; M M Whitacre; K D Siegmund
Journal:  Ophthalmology       Date:  1997-06       Impact factor: 12.079

7.  The effect of corneal thickness on applanation tonometry.

Authors:  M M Whitacre; R A Stein; K Hassanein
Journal:  Am J Ophthalmol       Date:  1993-05-15       Impact factor: 5.258

8.  Applanation tonometry and correction according to corneal thickness.

Authors:  R Stodtmeister
Journal:  Acta Ophthalmol Scand       Date:  1998-06

9.  Refractive errors, intraocular pressure, and glaucoma in a white population.

Authors:  Tien Yin Wong; Barbara E K Klein; Ronald Klein; Michael Knudtson; Kristine E Lee
Journal:  Ophthalmology       Date:  2003-01       Impact factor: 12.079

10.  Intraocular pressure after excimer laser photorefractive keratectomy for myopia.

Authors:  I Schipper; P Senn; U Thomann; M Suppiger
Journal:  J Refract Surg       Date:  1995 Sep-Oct       Impact factor: 3.573

View more
  5 in total

1.  Retinal measurements using time domain OCT imaging before and after myopic Lasik.

Authors:  Lei Feng; Feng Lei; Stephen A Burns; Liqin Shao; Yabo Yang
Journal:  Ophthalmic Physiol Opt       Date:  2012-05       Impact factor: 3.117

2.  Comparison of Three Tonometers in Measuring Intraocular Pressure in Eyes That Underwent Myopic Laser in situ Keratomileusis and Photorefractive Keratectomy.

Authors:  Robert Edward T Ang; Neiman Vincent R Bargas; Gladness Henna A Martinez; George Michael N Sosuan; Maria Isabel Nabor-Umali
Journal:  Clin Ophthalmol       Date:  2022-05-27

3.  [Goldmann applanation tonometry and dynamic contour tonometry. Comparison of intraocular pressure measurements in the course of product certification according to EN ISO 8612:2001].

Authors:  E M Hoffmann; N Pfeiffer; L Barleon; F H Grus
Journal:  Ophthalmologe       Date:  2006-04       Impact factor: 1.059

4.  Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractive surgery.

Authors:  Sang Yeop Lee; Hyoung Won Bae; Hee Jung Kwon; Gong Je Seong; Chan Yun Kim
Journal:  PLoS One       Date:  2018-02-05       Impact factor: 3.240

5.  Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery.

Authors:  Shireen Ma Shousha; Mahmoud Ah Abo Steit; Mohamed Hm Hosny; Wael A Ewais; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-01-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.