The effect of corneal thickness on applanation tonometry.

M M Whitacre1, R A Stein, K Hassanein.   

Abstract

Simultaneous manometry and Perkins tonometry were performed at 10.0, 20.0, and 30.0 mm Hg on 15 eyes on which intraocular procedures were performed. There was a statistically significant relationship between corneal thickness and the error of Perkins tonometry. Thin corneas produced underestimations of the intraocular pressure by as much as 4.9 mm Hg, whereas thick corneas produced overestimations by as much as 6.8 mm Hg. Measuring the corneal thickness is necessary to interpret properly the results of Goldmann applanation tonometry, particularly in eyes with thin corneas.

Mesh:

Year:  1993        PMID: 8488910     DOI: 10.1016/s0002-9394(14)71455-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  110 in total

1.  Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.

Authors:  N Feltgen; D Leifert; J Funk
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

2.  Measurement of intraocular pressure after epikeratophakia.

Authors:  M M Wright; A L Grajewski
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

3.  Cornea plana associated with open-angle glaucoma: a case report.

Authors:  Bilge Ozturk Sahin; Goktug Seymenoglu; Esin F Baser
Journal:  Int Ophthalmol       Date:  2011-12-11       Impact factor: 2.031

4.  Comparison of corneal biomechanical properties between healthy blacks and whites using the Ocular Response Analyzer.

Authors:  Mauro T Leite; Luciana M Alencar; Charlotte Gore; Robert N Weinreb; Pamela A Sample; Linda M Zangwill; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2010-06-11       Impact factor: 5.258

5.  Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness.

Authors:  S Miglior; E Albe; M Guareschi; G Mandelli; S Gomarasca; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

6.  Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects.

Authors:  Ioannis Halkiadakis; Aimilianos Stratos; George Stergiopoulos; Eleni Patsea; Sotiris Skouriotis; Panagiotis Mitropoulos; Dimitrios Papaconstantinou; Gerasimos Georgopoulos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-08       Impact factor: 3.117

7.  Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver.

Authors:  Umit Aykan; Mesut Erdurmus; Burhan Yilmaz; Ahmet Hamdi Bilge
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

8.  Correlations between corneal and optic nerve head variables in healthy subjects and patients with primary open angle glaucoma.

Authors:  Federico Saenz-Frances; Luis Jañez; Lara Borrego-Sanz; Clara Berrozpe-Villabona; Jose Maria Martinez-de-la-Casa; Laura Morales-Fernandez; Julian Garcia-Sanchez; Enrique Santos-Bueso; Julian Garcia-Feijoo
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

9.  Effects of primary selective laser trabeculoplasty on anterior segment parameters.

Authors:  Suzan Guven Yilmaz; Melis Palamar; Emil Yusifov; Halil Ates; Sait Egrilmez; Ayse Yagci
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

10.  Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study.

Authors:  Mona Pache; Sonja Wilmsmeyer; Sonja Lautebach; Jens Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-09       Impact factor: 3.117