Reliability coefficients of three corneal pachymeters.

N C Wheeler1, C M Morantes, R M Kristensen, T H Pettit, D A Lee.   

Abstract

We compared the accuracy and reproducibility of a hand-held portable ultrasound pachymeter, the Pach-Pen (Bio-Rad, Ophthalmic Division, Santa Ana, California); another ultrasound pachymeter, the DGH 1000 (DGH Technology, Inc., Frazer, Pennsylvania); and the Pro-Cem 4 endothelial specular microscope (Alcon-Surgical, Inc., Irvine, California). Each eye of 18 healthy human subjects was examined to determine corneal thickness using the three different instruments. For each instrument, five repeated measurements were obtained at each of five corneal locations (one central, four peripheral), for a total of 25 measurements per eye. The accuracy of the two ultrasound pachymeters was tested by comparing measurements obtained on specially designed test blocks of known thickness. The Pach-Pen was the more accurate of the two ultrasound pachymeters, with measurements within the range of 0.003 to 0.065 mm from the true thickness. The three instruments were most consistent in mean thickness in the center of the cornea. All three instruments showed excellent intraobserver reproducibility, as measured by reliability coefficients over 90%. Overall, the Pach-Pen pachymeter had high reproducibility, and produced more accurate measurements than the DGH 1000 pachymeter.

Entities:  

Mesh:

Year:  1992        PMID: 1598955     DOI: 10.1016/s0002-9394(14)74788-9

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  17 in total

1.  Corneal thickness and endothelial density before and after cataract surgery.

Authors:  A C Ventura; R Wälti; M Böhnke
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

2.  Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness.

Authors:  S Miglior; E Albe; M Guareschi; G Mandelli; S Gomarasca; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

Review 3.  In vivo confocal microscopy of the human cornea.

Authors:  I Jalbert; F Stapleton; E Papas; D F Sweeney; M Coroneo
Journal:  Br J Ophthalmol       Date:  2003-02       Impact factor: 4.638

4.  Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry.

Authors:  Yong-Heng Luo; Qian Zhong; Ping-Bo Ouyang; Xiao-Jian Guo; Xuan-Chu Duan
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

Review 5.  [Glaucoma diagnostics and corneal thickness].

Authors:  J von Eicken; M Kohlhaas; H Höh
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

6.  Effects of corneal thickness on intraocular pressure measured with three different tonometers.

Authors:  Hiroki Murase; Akira Sawada; Kiyofumi Mochizuki; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2009-01-30       Impact factor: 2.447

7.  Measurement of central corneal thickness in health and disease.

Authors:  Imtiaz A Chaudhry
Journal:  Saudi J Ophthalmol       Date:  2009-10

8.  Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT.

Authors:  David Kuerten; Niklas Plange; Eva Charlotte Koch; Antonis Koutsonas; Peter Walter; Matthias Fuest
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-21       Impact factor: 3.117

9.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

10.  Central corneal thickness in Northwestern American Indians/Alaskan Natives and comparison with White and African-American persons.

Authors:  Rodrigo J Torres; Emily Jones; Beth Edmunds; Thomas Becker; George A Cioffi; Steven L Mansberger
Journal:  Am J Ophthalmol       Date:  2008-07-30       Impact factor: 5.258

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.