Literature DB >> 3486963

Design and clinical utility of a fan beam collimator for SPECT imaging of the head.

B M Tsui, G T Gullberg, E R Edgerton, D R Gilland, J R Perry, W H McCartney.   

Abstract

A long bore fan beam collimator for imaging the head was designed and constructed for a SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder during rotation of the camera with a thick camera housing, the long bore design is necessary to allow the collimator to get close to the patient's head for improved spatial resolution. Operating at the minimum radius of rotation, the prototype fan beam collimator provides about the same spatial resolution as the high resolution collimator, while the geometric efficiency is equal to approximately 85% of that of the general purpose and approximately 55% higher than the high resolution collimator. Images from a phantom study demonstrate good image quality and are void of artifacts. Comparative clinical studies on temporomandibular joints (TMJ) between the LEGP and fan beam collimators also confirm the superior image quality obtained with the fan beam collimator.

Entities:  

Mesh:

Year:  1986        PMID: 3486963

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  10 in total

Review 1.  Collimator design for single photon emission tomography.

Authors:  S C Moore; K Kouris; I Cullum
Journal:  Eur J Nucl Med       Date:  1992

2.  Physical assessment of the GE/CGR Neurocam and comparison with a single rotating gamma-camera.

Authors:  K Kouris; P H Jarritt; D C Costa; P J Ell
Journal:  Eur J Nucl Med       Date:  1992

3.  Performance of a multislice fan beam collimator for SPECT imaging of the head.

Authors:  Y Akiyama; N Yui
Journal:  Ann Nucl Med       Date:  1991-09       Impact factor: 2.668

Review 4.  Brain single-photon emission CT physics principles.

Authors:  R Accorsi
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-26       Impact factor: 3.825

5.  Brain SPECT Simulation Using Half-Cone-Beam Collimation and Single-Revolution Helical-Path Acquisition.

Authors:  Ruben Ter-Antonyan; Ronald J Jaszczak; James E Bowsher; Kim L Greer; Scott D Metzler
Journal:  IEEE Trans Nucl Sci       Date:  2007       Impact factor: 1.679

6.  Stimulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffmann brain phantom: collimator and filter selection in SPECT neuroimaging.

Authors:  H J Kim; J S Karp; P D Mozley; S O Yang; D H Moon; H F Kung; H K Lee; A Alavi
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

7.  A unified computer program for assessment of attenuation correction and data acquisition methods in single photon emission computed tomography (SPECT).

Authors:  K Murase; S Tanada; H Higashino; M Yamada; M Miyagawa; A Iio; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1989

8.  Feasibility Study of Compton Scattering Enhanced Multiple Pinhole Imager for Nuclear Medicine.

Authors:  L J Meng; W L Rogers; N H Clinthorne
Journal:  IEEE Trans Nucl Sci       Date:  2003-10-27       Impact factor: 1.679

9.  Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Arda Konik; Timothy J Fromme; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

10.  Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators.

Authors:  Keishin Morita; Akira Maebatake; Rina Iwasaki; Yuki Shiotsuki; Kazuhiko Himuro; Shingo Baba; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.