We compared a prototype long-bore (LB) high-resolution collimator with a low-energy, general-purpose collimator (LEGP) using 99mTc and 123I. The LB collimator provided a 56% improvement in tomographic resolution (autocorrelation width) over the LEGP for 99mTc; for 123I, the gain was 79%, providing substantially improved contrast for small structures. The sensitivity of the LB collimator, however, is only 32% of that of the LEGP. The imaging tasks to be performed on [123I]IMP brain scans involve localization and discrimination of small, high-contrast brain structures and detection of abnormalities in shape, size, or uptake, rather than simple detection of lesions. Observer performance in such higher-order imaging tasks is known to depend on high spatial resolution, even at the cost of sensitivity. Patient studies confirmed that, for resolution-limited tasks, the increase in resolution outweighs the increased noise due to a loss in sensitivity. When the tomographic resolution of the LB collimator was degraded by smoothing to that of the LEGP, the noise in the LB images was lower than that of the LEGP by a factor of 2.9 for the same imaging time, demonstrating the advantage of high-resolution detectors and a smooth reconstruction filter over low-resolution detectors without smoothing. Therefore, collimators designed for high resolution, even at substantial cost in sensitivity, are expected to yield significant improvements for brain SPECT. Geometric calculations show that commercially available low-energy, high-resolution cast collimators promise to meet these requirements.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3021935

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

Review 1.  Collimator design for single photon emission tomography.

Authors:  S C Moore; K Kouris; I Cullum
Journal:  Eur J Nucl Med       Date:  1992

2.  Physical assessment of the GE/CGR Neurocam and comparison with a single rotating gamma-camera.

Authors:  K Kouris; P H Jarritt; D C Costa; P J Ell
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

4.  Optimum tomographic reconstruction parameters for HMPAO brain SPET imaging: a practical approach based on subjective and objective indexes.

Authors:  P O Kotzki; D Mariano-Goulart; M Quiquere; F Lyonnet; M Zanca; M Rossi
Journal:  Eur J Nucl Med       Date:  1995-07

Review 5.  Multidetector single-photon emission tomography: are two (or three or four) heads really better than one?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1993-05

6.  Design of a Multi-Pinhole Collimator for I-123 DaTscan Imaging on Dual-Headed SPECT Systems in Combination with a Fan-Beam Collimator.

Authors:  Michael A King; Joyeeta M Mukherjee; Arda Könik; I George Zubal; Joyoni Dey; Robert Licho
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-03       Impact factor: 1.679

7.  Favorable biodistribution of 99mTc-ECD for brain SPECT comparing with 123I-IMP using alternative body scan.

Authors:  K Hayashida; T Nishimura; S Imakita; T Uehara
Journal:  Ann Nucl Med       Date:  1992-11       Impact factor: 2.668

Review 8.  Insight into the Molecular Imaging of Alzheimer's Disease.

Authors:  Abishek Arora; Neeta Bhagat
Journal:  Int J Biomed Imaging       Date:  2016-01-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.