Literature DB >> 2395011

Brain perfusion SPECT using an annular single crystal camera: initial clinical experience.

B L Holman1, P A Carvalho, R E Zimmerman, K A Johnson, S S Tumeh, A P Smith, S Genna.   

Abstract

The annular single-crystal brain camera (ASPECT) is a digital SPECT system with a single-crystal sodium iodide thallium Nal(Tl) ring detector and collimator system designed to view the patient's head from three angles simultaneously. The ring is rotated concentrically to the detector for three-dimensional reconstruction over a 21.4 cm (diameter) by 10.7 cm (length) field of view. We evaluated the system clinically by imaging a Hoffman brain phantom and seven subjects, of whom two were normal controls, three had previous cerebral infarction and two had dementia. The ASPECT system produced tomographic images of high spatial resolution. In normal subjects, the separation of striata from thalami by the posterior limbs of the internal capsules was much clearer on ASPECT images than on rotating gamma camera images. The high spatial resolution obtained with the ASPECT system translates into superior anatomical representation of the brain compared to the standard rotating gamma camera.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2395011

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

1.  Nuclear medicine 2000.

Authors:  O Schober
Journal:  Eur J Nucl Med       Date:  1992

Review 2.  Collimator design for single photon emission tomography.

Authors:  S C Moore; K Kouris; I Cullum
Journal:  Eur J Nucl Med       Date:  1992

3.  Physical assessment of the GE/CGR Neurocam and comparison with a single rotating gamma-camera.

Authors:  K Kouris; P H Jarritt; D C Costa; P J Ell
Journal:  Eur J Nucl Med       Date:  1992

4.  Case report: regional cerebral hypoperfusion induced by ventricular tachycardia - short-term hippocampal hypoperfusion and its potential relationship to selective neuronal damage.

Authors:  A Hagendorff; E Klemm; M Bangard; C Dettmers; C Wolpert; B Schumacher; H J Biersack; F Grünwald; B Lüderitz; D Pfeiffer
Journal:  J Interv Card Electrophysiol       Date:  2001-12       Impact factor: 1.900

5.  Single photon emission computed tomography perfusion differences in mild cognitive impairment.

Authors:  K A Johnson; E K Moran; J A Becker; D Blacker; A J Fischman; M S Albert
Journal:  J Neurol Neurosurg Psychiatry       Date:  2006-10-20       Impact factor: 10.154

6.  18F-fluorodeoxyglucose-PET and 99mTc-bicisate-SPECT in Creutzfeldt-Jakob disease.

Authors:  F Grünwald; C Pohl; H Bender; A Hartmann; C Menzel; J Ruhlmann; E Keller; H J Biersack
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

7.  Different thallium-201 single-photon emission tomographic patterns in benign and aggressive meningiomas.

Authors:  E Tedeschi; A Soricelli; A Brunetti; M Romano; A Bucciero; G Iaconetta; A Alfieri; A Postiglione; M Salvatore
Journal:  Eur J Nucl Med       Date:  1996-11

8.  Optimization of Butterworth filter for brain SPECT imaging.

Authors:  S Minoshima; H Maruno; N Yui; T Togawa; F Kinoshita; M Kubota; K L Berger; Y Uchida; K Uno; N Arimizu
Journal:  Ann Nucl Med       Date:  1993-05       Impact factor: 2.668

9.  Brain single-photon emission tomography using technetium-99m bicisate (ECD) in a case of complex partial seizure.

Authors:  C Menzel; F Grünwald; L Pavics; A Hufnagel; B Stawovy; K Reichmann; C E Elger; H J Biersack
Journal:  Eur J Nucl Med       Date:  1994-11

10.  18FDG PET and acetazolamide-enhanced 99mTc-HMPAO SPET in systemic lupus erythematosus.

Authors:  F Grünwald; A Schomburg; A Badali; J Ruhlmann; L Pavics; H J Biersack
Journal:  Eur J Nucl Med       Date:  1995-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.