Literature DB >> 15895588

Density resolution of proton computed tomography.

Reinhard W Schulte1, Vladimir Bashkirov, Márgio C Loss Klock, Tianfang Li, Andrew J Wroe, Ivan Evseev, David C Williams, Todd Satogata.   

Abstract

Conformal proton radiation therapy requires accurate prediction of the Bragg peak position. Protons may be more suitable than conventional x-rays for this task since the relative electron density distribution can be measured directly with proton computed tomography (CT). However, proton CT has its own limitations, which need to be carefully studied before this technique can be introduced into routine clinical practice. In this work, we have used analytical relationships as well as the Monte Carlo simulation tool GEANT4 to study the principal resolution limits of proton CT. The noise level observed in proton CT images of a cylindrical water phantom with embedded tissue-equivalent density inhomogeneities, which were generated based on GEANT4 simulations, compared well with predictions based on Tschalar's theory of energy loss straggling. The relationship between phantom thickness, initial energy, and the relative electron density resolution was systematically investigated to estimate the proton dose needed to obtain a given density resolution. We show that a reasonable density resolution can be achieved with a relatively small dose, which is comparable to or even lower than that of x-ray CT.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15895588     DOI: 10.1118/1.1884906

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Total variation superiorization schemes in proton computed tomography image reconstruction.

Authors:  S N Penfold; R W Schulte; Y Censor; A B Rosenfeld
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

2.  Reconstruction for proton computed tomography by tracing proton trajectories: a Monte Carlo study.

Authors:  Tianfang Li; Zhengrong Liang; Jayalakshmi V Singanallur; Todd J Satogata; David C Williams; Reinhard W Schulte
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

3.  The effect of beam purity and scanner complexity on proton CT accuracy.

Authors:  P Piersimoni; J Ramos-Méndez; T Geoghegan; V A Bashkirov; R W Schulte; B A Faddegon
Journal:  Med Phys       Date:  2017-01-09       Impact factor: 4.071

4.  200 MeV proton radiography studies with a hand phantom using a prototype proton CT scanner.

Authors:  Tia Plautz; V Bashkirov; V Feng; F Hurley; R P Johnson; C Leary; S Macafee; A Plumb; V Rykalin; H F-W Sadrozinski; K Schubert; R Schulte; B Schultze; D Steinberg; M Witt; A Zatserklyaniy
Journal:  IEEE Trans Med Imaging       Date:  2014-04       Impact factor: 10.048

5.  New developments in treatment planning and verification of particle beam therapy.

Authors:  Reinhard W Schulte; Andrew J Wroe
Journal:  Transl Cancer Res       Date:  2012-10-01       Impact factor: 1.241

6.  Bragg peak prediction from quantitative proton computed tomography using different path estimates.

Authors:  Dongxu Wang; T Rockwell Mackie; Wolfgang A Tomé
Journal:  Phys Med Biol       Date:  2011-01-06       Impact factor: 3.609

7.  Fast In Situ Image Reconstruction for Proton Radiography.

Authors:  Caesar E Ordoñez; Nicholas T Karonis; Kirk L Duffin; John R Winans; Ethan A DeJongh; Don F DeJongh; George Coutrakon; Nicole F Myers; Mark Pankuch; James S Welsh
Journal:  J Radiat Oncol       Date:  2019-05-25

8.  A comparison of proton stopping power measured with proton CT and x-ray CT in fresh postmortem porcine structures.

Authors:  Don F DeJongh; Ethan A DeJongh; Victor Rykalin; Greg DeFillippo; Mark Pankuch; Andrew W Best; George Coutrakon; Kirk L Duffin; Nicholas T Karonis; Caesar E Ordoñez; Christina Sarosiek; Reinhard W Schulte; John R Winans; Alec M Block; Courtney L Hentz; James S Welsh
Journal:  Med Phys       Date:  2021-11-18       Impact factor: 4.071

9.  Proton CT for Improved Stopping Power Determination in Proton Therapy, invited.

Authors:  Reinhard W Schulte; Scott N Penfold
Journal:  Trans Am Nucl Soc       Date:  2012

10.  The impact of secondary fragments on the image quality of helium ion imaging.

Authors:  Lennart Volz; Pierluigi Piersimoni; Vladimir A Bashkirov; Stephan Brons; Charles-Antoine Collins-Fekete; Robert P Johnson; Reinhard W Schulte; Joao Seco
Journal:  Phys Med Biol       Date:  2018-10-02       Impact factor: 3.609

View more