Literature DB >> 21158301

Total variation superiorization schemes in proton computed tomography image reconstruction.

S N Penfold1, R W Schulte, Y Censor, A B Rosenfeld.   

Abstract

PURPOSE: Iterative projection reconstruction algorithms are currently the preferred reconstruction method in proton computed tomography (pCT). However, due to inconsistencies in the measured data arising from proton energy straggling and multiple Coulomb scattering, the noise in the reconstructed image increases with successive iterations. In the current work, the authors investigated the use of total variation superiorization (TVS) schemes that can be applied as an algorithmic add-on to perturbation-resilient iterative projection algorithms for pCT image reconstruction.
METHODS: The block-iterative diagonally relaxed orthogonal projections (DROP) algorithm was used for reconstructing GEANT4 Monte Carlo simulated pCT data sets. Two TVS schemes added on to DROP were investigated; the first carried out the superiorization steps once per cycle and the second once per block. Simplifications of these schemes, involving the elimination of the computationally expensive feasibility proximity checking step of the TVS framework, were also investigated. The modulation transfer function and contrast discrimination function were used to quantify spatial and density resolution, respectively.
RESULTS: With both TVS schemes, superior spatial and density resolution was achieved compared to the standard DROP algorithm. Eliminating the feasibility proximity check improved the image quality, in particular image noise, in the once-per-block superiorization, while also halving image reconstruction time. Overall, the greatest image quality was observed when carrying out the superiorization once per block and eliminating the feasibility proximity check.
CONCLUSIONS: The low-contrast imaging made possible with TVS holds a promise for its incorporation into future pCT studies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21158301      PMCID: PMC2980547          DOI: 10.1118/1.3504603

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Image restoration subject to a total variation constraint.

Authors:  Patrick L Combettes; Jean-Christophe Pesquet
Journal:  IEEE Trans Image Process       Date:  2004-09       Impact factor: 10.856

2.  Density resolution of proton computed tomography.

Authors:  Reinhard W Schulte; Vladimir Bashkirov; Márgio C Loss Klock; Tianfang Li; Andrew J Wroe; Ivan Evseev; David C Williams; Todd Satogata
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

3.  Reconstruction for proton computed tomography by tracing proton trajectories: a Monte Carlo study.

Authors:  Tianfang Li; Zhengrong Liang; Jayalakshmi V Singanallur; Todd J Satogata; David C Williams; Reinhard W Schulte
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

4.  An adaptive level set method for nondifferentiable constrained image recovery.

Authors:  Patrick L Combettes; Jian Luo
Journal:  IEEE Trans Image Process       Date:  2002       Impact factor: 10.856

5.  A maximum likelihood proton path formalism for application in proton computed tomography.

Authors:  R W Schulte; S N Penfold; J T Tafas; K E Schubert
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

6.  A more accurate reconstruction system matrix for quantitative proton computed tomography.

Authors:  S N Penfold; A B Rosenfeld; R W Schulte; K E Schubert
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

7.  Perturbation-resilient block-iterative projection methods with application to image reconstruction from projections.

Authors:  R Davidi; G T Herman; Y Censor
Journal:  Int Trans Oper Res       Date:  2008-02-11       Impact factor: 4.193

8.  Perturbation Resilience and Superiorization of Iterative Algorithms.

Authors:  Y Censor; R Davidi; G T Herman
Journal:  Inverse Probl       Date:  2010-06-01       Impact factor: 2.407

9.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

10.  On Image Reconstruction from a Small Number of Projections.

Authors:  G T Herman; R Davidi
Journal:  Inverse Probl       Date:  2008-08       Impact factor: 2.407

  10 in total
  23 in total

1.  Novel scintillation detector design and performance for proton radiography and computed tomography.

Authors:  V A Bashkirov; R W Schulte; R F Hurley; R P Johnson; H F-W Sadrozinski; A Zatserklyaniy; T Plautz; V Giacometti
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  An evaluation of spatial resolution of a prototype proton CT scanner.

Authors:  Tia E Plautz; V Bashkirov; V Giacometti; R F Hurley; R P Johnson; P Piersimoni; H F-W Sadrozinski; R W Schulte; A Zatserklyaniy
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

3.  Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med       Date:  2020-04-28       Impact factor: 2.685

4.  The effect of beam purity and scanner complexity on proton CT accuracy.

Authors:  P Piersimoni; J Ramos-Méndez; T Geoghegan; V A Bashkirov; R W Schulte; B A Faddegon
Journal:  Med Phys       Date:  2017-01-09       Impact factor: 4.071

Review 5.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

6.  Proton CT for Improved Stopping Power Determination in Proton Therapy, invited.

Authors:  Reinhard W Schulte; Scott N Penfold
Journal:  Trans Am Nucl Soc       Date:  2012

7.  Helium CT: Monte Carlo simulation results for an ideal source and detector with comparison to proton CT.

Authors:  Pierluigi Piersimoni; Bruce A Faddegon; José Ramos Méndez; Reinhard W Schulte; Lennart Volz; Joao Seco
Journal:  Med Phys       Date:  2018-05-20       Impact factor: 4.071

8.  Development of proton computed tomography detectors for applications in hadron therapy.

Authors:  Vladimir A Bashkirov; Robert P Johnson; Hartmut F-W Sadrozinski; Reinhard W Schulte
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-08-08       Impact factor: 1.455

9.  Accelerated perturbation-resilient block-iterative projection methods with application to image reconstruction.

Authors:  T Nikazad; R Davidi; G T Herman
Journal:  Inverse Probl       Date:  2012-02-10       Impact factor: 2.407

10.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.