Literature DB >> 15803302

In vitro study and semiempirical model for aerosol delivery control during mechanical ventilation.

Laurent Vecellio1, Claude Guérin, Daniel Grimbert, Michele De Monte, Patrice Diot.   

Abstract

The object of this study was to evaluate in vitro the influence of various ventilatory parameters on the delivery of synchronized nebulization of terbutaline during mechanical ventilation and to determine a semiempirical model to control the quantity of aerosol delivered into the patient's lung. An ATOMISOR NL9 M jet nebulizer (La Diffusion Technique Francaise, France) was filled with terbutaline (Bricanyl, Astra-Zeneca, Sweden) and connected to the inspiratory line of a Horus ventilator (Taema, France). Nebulization was synchronized with the inspiratory phase. We assessed at the end of the endotracheal tube the quantity of terbutaline (terbutaline mass output) and the volume median diameter (VMD) by diffraction-laser method. There was a negative correlation between terbutaline mass output and inspiratory air flow ( r =-0.95, p <0.0001) and between VMD and inspiratory air flow ( r =-0.96, p <0.0001). Moreover, positive end-expiratory pressure levels between 0 cm and 8 cm of water did not significantly change the terbutaline output mass ( p =0.22). Total nebulization time and terbutaline mass output calculated by the mathematical model showed good agreement with experimental data. In conclusion, our semiempirical model allows calculation of the duration of the nebulization required to deliver a given mass of terbutaline into patient lungs.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15803302     DOI: 10.1007/s00134-005-2594-4

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  11 in total

1.  A simple in vitro method for the evaluation of an ultrasonic nebulizer for drug delivery to intubated, ventilated patients and the effect of nebulizer and ventilator settings on the uptake of fluid from the nebulizer chamber.

Authors:  L Williams; G C Fletcher; M Daniel; J Kinsella
Journal:  Eur J Anaesthesiol       Date:  1999-07       Impact factor: 4.330

2.  Nebulizer function during mechanical ventilation.

Authors:  T G O'Riordan; M J Greco; R J Perry; G C Smaldone
Journal:  Am Rev Respir Dis       Date:  1992-05

Review 3.  Inhaled bronchodilator therapy in mechanically ventilated patients.

Authors:  R Dhand; M J Tobin
Journal:  Am J Respir Crit Care Med       Date:  1997-07       Impact factor: 21.405

4.  Jet nebulization of budesonide suspension into a neonatal ventilator circuit: synchronized versus continuous nebulizer flow.

Authors:  A S Pelkonen; K Nikander; M Turpeinen
Journal:  Pediatr Pulmonol       Date:  1997-10

5.  Albuterol delivery in a model of mechanical ventilation. Comparison of metered-dose inhaler and nebulizer efficiency.

Authors:  P Diot; L Morra; G C Smaldone
Journal:  Am J Respir Crit Care Med       Date:  1995-10       Impact factor: 21.405

6.  Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.

Authors:  J B Fink; R Dhand; J Grychowski; P J Fahey; M J Tobin
Journal:  Am J Respir Crit Care Med       Date:  1999-01       Impact factor: 21.405

7.  Aerosol delivery and modern mechanical ventilation: in vitro/in vivo evaluation.

Authors:  Dorisanne D Miller; Mohammad M Amin; Lucy B Palmer; Akbar R Shah; Gerald C Smaldone
Journal:  Am J Respir Crit Care Med       Date:  2003-07-31       Impact factor: 21.405

8.  Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill.

Authors:  M J O'Doherty; S H Thomas; C J Page; D F Treacher; T O Nunan
Journal:  Am Rev Respir Dis       Date:  1992-08

9.  The delivery of therapeutic aerosols through endotracheal tubes.

Authors:  R C Ahrens; R A Ries; W Popendorf; J A Wiese
Journal:  Pediatr Pulmonol       Date:  1986 Jan-Feb

10.  Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.

Authors:  C J Harvey; M J O'Doherty; C J Page; S H Thomas; T O Nunan; D F Treacher
Journal:  Thorax       Date:  1995-01       Impact factor: 9.139

View more
  5 in total

Review 1.  Year in review in intensive care medicine, 2005. III. Nutrition, pediatric and neonatal critical care, and experimental.

Authors:  Peter Andrews; Elie Azoulay; Massimo Antonelli; Laurent Brochard; Christian Brun-Buisson; Geoffrey Dobb; Jean-Yves Fagon; Herwig Gerlach; Johan Groeneveld; Jordi Mancebo; Philipp Metnitz; Stefano Nava; Jerome Pugin; Michael Pinsky; Peter Radermacher; Christian Richard; Robert Tasker
Journal:  Intensive Care Med       Date:  2006-02-18       Impact factor: 17.440

2.  Aerosol therapy in intensive and intermediate care units: prospective observation of 2808 critically ill patients.

Authors:  Stephan Ehrmann; Ferran Roche-Campo; Laetitia Bodet-Contentin; Keyvan Razazi; Jonathan Dugernier; Josep Trenado-Alvarez; Alexis Donzeau; François Vermeulen; David Thévoz; Metaxia Papanikolaou; Antoine Edelson; Héctor León Yoshido; Lise Piquilloud; Karim Lakhal; Carlos Lopes; Carlos Vicent; Arnaud Desachy; Gabriela Apiou-Sbirlea; Daniel Isabey; Laurent Brochard
Journal:  Intensive Care Med       Date:  2015-11-24       Impact factor: 17.440

3.  Pharmacokinetics of high-dose nebulized amikacin in mechanically ventilated healthy subjects.

Authors:  Stephan Ehrmann; Emmanuelle Mercier; Laurent Vecellio; David Ternant; Gilles Paintaud; Pierre-François Dequin
Journal:  Intensive Care Med       Date:  2007-11-29       Impact factor: 17.440

4.  The Clinical Practice and Best Aerosol Delivery Location in Intubated and Mechanically Ventilated Patients: A Randomized Clinical Trial.

Authors:  Chuanlin Zhang; Jie Mi; Zeju Zhang; Xueqin Wang; Yunxiao Zhu; Xinyi Luo; Ruiying Gan; Xiaoya Chen; Yujun Zou
Journal:  Biomed Res Int       Date:  2021-04-03       Impact factor: 3.411

5.  Aerosol delivery by an ultrasonic nebulizer during different mechanical ventilation settings in a lung model--a pilot study.

Authors:  Michael Winterhalter; Michael Bund; Nawid Khaladj; Christian Hagl; Andre Simon; Ludwig Hoy; Siegfried Piepenbrock; Niels Rahe-Meyer
Journal:  Drug Des Devel Ther       Date:  2009-02-06       Impact factor: 4.162

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.