Albuterol delivery in a model of mechanical ventilation. Comparison of metered-dose inhaler and nebulizer efficiency.

P Diot1, L Morra, G C Smaldone.   

Abstract

Using an in vitro model, we compared efficiencies of jet nebulizers and metered-dose inhalers (MDI) with actuator devices to deliver albuterol in various conditions of mechanical ventilation. Factors tested included influence of humidification, MDI actuator device (Aerovent spacer or Marquest 172275 MDI adaptor), and synchronization of MDI to the respiratory cycle. With the nebulizer (AeroTech II) filled with 2.5 mg albuterol sulfate in 3 ml water and run until dry, inhaled mass was 42 +/- 2.6% and mass median aerodynamic diameter (MMAD) was 1.3 microns on a nonhumidified circuit. With the MDI+ Aerovent, the inhaled mass percentage per 90 microgm puff was 15.4 +/- 0.2% with humidification and 25.1 +/- 3.7% without humidification, actuations being synchronized with the beginning of inspiration and separated by a 1-min pause. Failure to synchronize actuations with inspiration or to pause 1 min resulted in significant reductions in inhaled mass (by 35 and 72%, respectively). The Marquest adaptor was less efficient, with an inhaled mass of 7.2 +/- 0.7% under optimal conditions. Metered-dose inhaler actuation during expiration resulted in relatively large particles (MMAD = 2.0 microns). All other MDI actuations led to essentially biphasic distributions, with particles greater than 1 micron following a distribution similar to the nebulizer and the overall MMAD estimated to be 0.22 microns. The AeroTech II delivered a cumulative 1,000 micrograms of drug (2,500 x 0.40) over 40 min. To achieve that amount, the MDI connected to the Aerovent and used in its most efficient sequence would require 45 timed puffs (90 micrograms per puff, 25.1% mean inhaled mass) and take 45 min of an experienced therapist's time.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7551401     DOI: 10.1164/ajrccm.152.4.7551401

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  19 in total

Review 1.  Challenges Associated with Route of Administration in Neonatal Drug Delivery.

Authors:  Matthew W Linakis; Jessica K Roberts; Anita C Lala; Michael G Spigarelli; Natalie J Medlicott; David M Reith; Robert M Ward; Catherine M T Sherwin
Journal:  Clin Pharmacokinet       Date:  2016-02       Impact factor: 6.447

Review 2.  Mechanical ventilation of the patient with severe chronic obstructive pulmonary disease.

Authors:  M T Gladwin; D J Pierson
Journal:  Intensive Care Med       Date:  1998-09       Impact factor: 17.440

3.  The use of condensational growth methods for efficient drug delivery to the lungs during noninvasive ventilation high flow therapy.

Authors:  Laleh Golshahi; Geng Tian; Mandana Azimi; Yoen-Ju Son; Ross Walenga; P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2013-06-26       Impact factor: 4.200

Review 4.  Pharmacologic treatment of the adult hospitalized asthma patient.

Authors:  M L Kreutzer; S Louie
Journal:  Clin Rev Allergy Immunol       Date:  2001-06       Impact factor: 8.667

Review 5.  Inhaled Antibiotics for Gram-Negative Respiratory Infections.

Authors:  Eric Wenzler; Dustin R Fraidenburg; Tonya Scardina; Larry H Danziger
Journal:  Clin Microbiol Rev       Date:  2016-07       Impact factor: 26.132

6.  In vitro study and semiempirical model for aerosol delivery control during mechanical ventilation.

Authors:  Laurent Vecellio; Claude Guérin; Daniel Grimbert; Michele De Monte; Patrice Diot
Journal:  Intensive Care Med       Date:  2005-04-01       Impact factor: 17.440

Review 7.  RNAi therapeutic strategies for acute respiratory distress syndrome.

Authors:  Melissa L Jagrosse; David A Dean; Arshad Rahman; Bradley L Nilsson
Journal:  Transl Res       Date:  2019-07-27       Impact factor: 7.012

Review 8.  Bronchodilators for the prevention and treatment of chronic lung disease in preterm infants.

Authors:  Geraldine Ng; Orlando da Silva; Arne Ohlsson
Journal:  Cochrane Database Syst Rev       Date:  2016-12-14

9.  Aerosol therapy during mechanical ventilation: an international survey.

Authors:  Stephan Ehrmann; Ferran Roche-Campo; Giuseppe Francesco Sferrazza Papa; Daniel Isabey; Laurent Brochard; Gabriela Apiou-Sbirlea
Journal:  Intensive Care Med       Date:  2013-03-23       Impact factor: 17.440

10.  In vitro evaluation of aerosol bronchodilator delivery during mechanical ventilation: pressure-control vs. volume control ventilation.

Authors:  Dean R Hess; Christine Dillman; Robert M Kacmarek
Journal:  Intensive Care Med       Date:  2003-05-15       Impact factor: 17.440

View more