Literature DB >> 16456651

Mutidetector-row CT and quantitative gated SPECT for the assessment of left ventricular function in small hearts: the cardiac physical phantom study using a combined SPECT/CT system.

Daisuke Utsunomiya1, Seiji Tomiguchi, Kazuo Awai, Shinya Shiraishi, Takeshi Nakaura, Yasuyuki Yamashita.   

Abstract

UNLABELLED: The aim of this study was to compare results of left ventricular (LV) function obtained by quantitative gated single-photon emission tomography (QGS) and multidetector-row spiral computed tomography (MDCT) with reference parameters using an electrocardiogram-gated cardiac physical phantom. The phantom study was performed using a combined SPECT/CT system. Flexible membranes formed the inner and outer walls of the simulated LV. The stroke volume was adjusted (45 mL or 58 mL) and the fixed 42-mL end-systolic volume (ESV) produced two different volume combinations. The LV function parameters were estimated by means of MDCT and QGS. Differences in true and measured volumes were compared among CT with a reconstructed image thickness of 2.5 mm and 5.0 mm and QGS volumetric values. Each scan was repeated three-times. The estimation of LV volumes using both QGS and MDCT analyses were reproducible very well. QGS overestimated ejection fraction (EF) by approximately 20%; MDCT volumetry overestimated EF by approximately 5% in each volume setting. The differences in true and measured values for EF and ESV obtained with QGS were significantly greater than obtained with MDCT.
CONCLUSION: MDCT provides a reliable estimation of functional LV parameters, whereas QGS tends to significantly overestimate the EF in small hearts.

Entities:  

Mesh:

Year:  2006        PMID: 16456651     DOI: 10.1007/s00330-005-0102-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  40 in total

1.  Assessment of left ventricular function by 201Tl SPECT using left ventricular cavity-to-myocardium count ratio.

Authors:  C Maunoury; T Antonietti; S Sebahoun; L Barritault
Journal:  Nucl Med Commun       Date:  2001-03       Impact factor: 1.690

2.  Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.

Authors:  Yasutaka Ichikawa; Hajime Sakuma; Kakuya Kitagawa; Nanaka Ishida; Kan Takeda; Shoko Uemura; Munenobu Motoyasu; Takeshi Nakano; Atsushi Nozaki
Journal:  J Cardiovasc Magn Reson       Date:  2003       Impact factor: 5.364

3.  Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

Authors:  Emmanuel Coche; Alain Vlassenbroek; Véronique Roelants; William D'Hoore; Franck Verschuren; Louis Goncette; Baudouin Maldague
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

Review 4.  Automatic analysis of ventricular function by nuclear imaging.

Authors:  G Germano
Journal:  Curr Opin Cardiol       Date:  1998-11       Impact factor: 2.161

5.  Two- and three-dimensional CT ventriculography: a new application of helical CT.

Authors:  T Mochizuki; K Murase; H Higashino; Y Koyama; M Doi; M Miyagawa; S Nakata; K Shimizu; J Ikezoe
Journal:  AJR Am J Roentgenol       Date:  2000-01       Impact factor: 3.959

Review 6.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms.

Authors:  N B Schiller; P M Shah; M Crawford; A DeMaria; R Devereux; H Feigenbaum; H Gutgesell; N Reichek; D Sahn; I Schnittger
Journal:  J Am Soc Echocardiogr       Date:  1989 Sep-Oct       Impact factor: 5.251

7.  Evaluation of left ventricular function by echocardiography.

Authors:  N J Fortuin; W P Hood; E Craige
Journal:  Circulation       Date:  1972-07       Impact factor: 29.690

8.  Comparison of Emory and Cedars-Sinai methods for assessment of left ventricular function from gated myocardial perfusion SPECT in patients with a small heart.

Authors:  M Toba; S Kumita; K Cho; S Mizumura; T Kijima; H Nakajo; T Kumazaki
Journal:  Ann Nucl Med       Date:  2000-12       Impact factor: 2.668

9.  Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging.

Authors:  Masaki Yamamuro; Eiji Tadamura; Shigeto Kubo; Hiroshi Toyoda; Takeshi Nishina; Muneo Ohba; Ryohei Hosokawa; Takeshi Kimura; Nagara Tamaki; Masashi Komeda; Toru Kita; Junji Konishi
Journal:  Radiology       Date:  2005-02       Impact factor: 11.105

10.  Repeatability of automatic left ventricular cavity volume measurements from myocardial perfusion SPECT.

Authors:  G Germano; P B Kavanagh; J T Kavanagh; S H Wishner; D S Berman; G J Kavanagh
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

View more
  2 in total

1.  Noninvasive modalities for the assessment of left ventricular function: all are equal but some are more equal than others.

Authors:  Tiong Keng Lim; Roxy Senior
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

Review 2.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.