Literature DB >> 16609861

Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods.

M Montaudon1, E Laffon, P Berger, O Corneloup, V Latrabe, F Laurent.   

Abstract

This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method.

Entities:  

Mesh:

Year:  2006        PMID: 16609861     DOI: 10.1007/s00330-006-0222-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

Review 1.  Ventricular function.

Authors:  S B Greenberg; S K Sandhu
Journal:  Radiol Clin North Am       Date:  1999-03       Impact factor: 2.303

2.  Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

Authors:  Kai Uwe Juergens; Matthias Grude; David Maintz; Eva Maria Fallenberg; Thomas Wichter; Walter Heindel; Roman Fischbach
Journal:  Radiology       Date:  2003-12-10       Impact factor: 11.105

3.  Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries.

Authors:  Koen Nieman; Peter M T Pattynama; Benno J Rensing; Robert-Jan M Van Geuns; Pim J De Feyter
Journal:  Radiology       Date:  2003-12       Impact factor: 11.105

4.  Sixteen-slice computed tomography after acute myocardial infarction: from perfusion defect to the culprit lesion.

Authors:  Jean-François Paul; Grégoire Dambrin; Christophe Caussin; Bernard Lancelin; Claude Angel
Journal:  Circulation       Date:  2003-07-22       Impact factor: 29.690

5.  [Left ventricular functional parameters using ECG-gated multidetector spiral CT in comparison with invasive ventriculography].

Authors:  M Heuschmid; A Küttner; S Schröder; B Trebar; C Burgstahler; A Mahnken; M Niethammer; T Trabold; A F Kopp; C D Claussen
Journal:  Rofo       Date:  2003-10

6.  Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging.

Authors:  Matthias Grude; Kai Uwe Juergens; Thomas Wichter; Matthias Paul; Eva Maria Fallenberg; Joachim Georg Muller; Walter Heindel; Guenter Breithardt; Roman Fischbach
Journal:  Invest Radiol       Date:  2003-10       Impact factor: 6.016

7.  Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

Authors:  Emmanuel Coche; Alain Vlassenbroek; Véronique Roelants; William D'Hoore; Franck Verschuren; Louis Goncette; Baudouin Maldague
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

8.  Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation.

Authors:  Thomas Schlosser; Konstantin Pagonidis; Christoph U Herborn; Peter Hunold; Kai-Uwe Waltering; Thomas C Lauenstein; Jörg Barkhausen
Journal:  AJR Am J Roentgenol       Date:  2005-03       Impact factor: 3.959

9.  Two- and three-dimensional CT ventriculography: a new application of helical CT.

Authors:  T Mochizuki; K Murase; H Higashino; Y Koyama; M Doi; M Miyagawa; S Nakata; K Shimizu; J Ikezoe
Journal:  AJR Am J Roentgenol       Date:  2000-01       Impact factor: 3.959

10.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

View more
  3 in total

1.  Integrated teaching of anatomy and radiology using three-dimensional image post-processing.

Authors:  Fabian Rengier; Sara Doll; Hendrik von Tengg-Kobligk; Joachim Kirsch; Hans-Ulrich Kauczor; Frederik L Giesel
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

2.  Evaluation of left atrial volumes using multidetector computed tomography: comparison with echocardiography.

Authors:  Hye Mi Gweon; Sang Jin Kim; Tae Hoon Kim; Sang Min Lee; Yoo Jin Hong; Se-Joong Rim
Journal:  Korean J Radiol       Date:  2010-04-30       Impact factor: 3.500

3.  Stereological estimation of left-ventricular volumetric and functional parameters from multidetector-row computed tomography data.

Authors:  Michalis Mazonakis; Konstantin Pagonidis; Thomas Schlosser; Peter Hunold; John Damilakis; Jörg Barkhausen; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.