Literature DB >> 15741628

Modular fixed-bearing total knee arthroplasty with retention of the posterior cruciate ligament. A study of patients followed for a minimum of fifteen years.

Michael C Dixon1, Richard R Brown, Dominik Parsch, Richard D Scott.   

Abstract

BACKGROUND: There have been a limited number of studies of total knee arthroplasties with durations of follow-up of fifteen years, but we are not aware of any involving modular fixed-bearing posterior cruciate-retaining prostheses.
METHODS: A consecutive series of 139 total knee arthroplasties in 109 patients (average age, sixty-seven years), performed by one surgeon using a nonconforming posterior cruciate-retaining prosthesis, was followed for fifteen years or longer. Forty-five patients (fifty-nine knees) were examined at a minimum of fifteen years postoperatively, fifty-seven patients (seventy knees) had died, five patients (eight knees) were too ill to return for assessment, and two patients (two knees) were considered lost to follow-up. The patients were assessed clinically with use of the Knee Society clinical rating system, and the knees were assessed radiographically. Survivorship analysis was performed with use of worst-case-scenario analysis and with failure defined as a reoperation for any reason.
RESULTS: There were five reoperations, four of which were performed because of wear of the polyethylene insert. In addition, one loose cemented femoral component was revised at fifteen years. The survival rate without revision or a need for any reoperation was 92.6% at fifteen years. The mean Knee Society score and functional score at fifteen years were 96 and 78 points, respectively. The prevalence of radiolucent lines was 13%, with 2% around the femur, 11% around the tibia, and none around the patella. None of these lines were clinically relevant. There was no evidence of progressive radiolucent lines, and there was one case of asymptomatic femoral osteolysis.
CONCLUSIONS: In this single-surgeon series, modular fixed-bearing posterior cruciate-retaining total knee arthroplasties had good clinical and radiographic results with excellent survivorship for up to fifteen years. These results are comparable with those in long-term studies of posterior stabilized implants and of prostheses with mobile-bearing and nonmodular tibial inserts.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15741628     DOI: 10.2106/JBJS.C.00591

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  41 in total

1.  The influence of patella height on intra-operative soft tissue balance in posterior-stabilized total knee arthroplasty.

Authors:  Hiroshi Sasaki; Seiji Kubo; Tomoyuki Matsumoto; Hirotsugu Muratsu; Takehiko Matsushita; Kazunari Ishida; Koji Takayama; Shinya Oka; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-27       Impact factor: 4.342

2.  Comparative study of tibial posterior slope angle following cruciate-retaining total knee arthroplasty using one of three implants.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon; Jung Ho Noh; Seong Cheol Moon
Journal:  Int Orthop       Date:  2011-12-06       Impact factor: 3.075

Review 3.  What is the evidence for total knee arthroplasty in young patients?: a systematic review of the literature.

Authors:  James A Keeney; Selena Eunice; Gail Pashos; Rick W Wright; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2010-09-03       Impact factor: 4.176

4.  Pulsed lavage improves fixation strength of cemented tibial components.

Authors:  Ulf J Schlegel; Jan Siewe; Karl S Delank; Peer Eysel; Klaus Püschel; Michael M Morlock; Anne Gebert de Uhlenbrock
Journal:  Int Orthop       Date:  2010-10-16       Impact factor: 3.075

5.  Cemented versus uncemented femoral components in total knee arthroplasty.

Authors:  Guillaume Demey; Elvire Servien; Sebastien Lustig; Tarik Aït Si Selmi; Philippe Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-12-15       Impact factor: 4.342

6.  Minimally invasive total knee arthroplasty using the contralateral knee as a control group: a case-control study.

Authors:  Peter M Bonutti; Michael G Zywiel; Thorsten M Seyler; Seung Yong Lee; Mike S McGrath; David R Marker; Michael A Mont
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

7.  Rotating platform versus fixed-bearing total knees: an in vitro study of wear.

Authors:  Hani Haider; Kevin Garvin
Journal:  Clin Orthop Relat Res       Date:  2008-08-29       Impact factor: 4.176

8.  [Current role of minimally invasive total knee arthroplasty. A meta-analysis].

Authors:  T Kappe; M Flören; R Bieger; H Reichel
Journal:  Orthopade       Date:  2011-08       Impact factor: 1.087

9.  Does a non-stemmed constrained condylar prosthesis predispose to early failure of primary total knee arthroplasty?

Authors:  Ajit J Deshmukh; Parthiv A Rathod; Michael J Moses; Nimrod Snir; Scott E Marwin; Alan J Dayan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-01       Impact factor: 4.342

10.  Modular versus nonmodular tibial inserts in total knee arthroplasty: what are the differences?

Authors:  Asim M Makhdom; Javad Parvizi
Journal:  Ann Transl Med       Date:  2017-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.