The desaturation response time of finger pulse oximeters during mild hypothermia.

D B MacLeod1, L I Cortinez, J C Keifer, D Cameron, D R Wright, W D White, E W Moretti, L R Radulescu, J Somma.   

Abstract

Pulse oximeters may delay displaying the correct oxygen saturation during the onset of hypoxia. We investigated the desaturation response times of pulse oximeter sensors (forehead, ear and finger) during vasoconstriction due to mild hypothermia and vasodilation caused by glyceryl trinitrate. Ten healthy male volunteers were given three hypoxic challenges of 3 min duration under differing experimental conditions. Mild hypothermia increased the mean response time of finger oximeters from 130 to 215 s. Glyceryl trinitrate partly offset this effect by reducing the response time from 215 to 187 s. In contrast, the response times of the forehead and ear oximeters were unaffected by mild hypothermia, but the difference between head and finger oximeters was highly significant (p < 0.0001). The results suggest that the head oximeters provide a better monitoring site for pulse oximeters during mild hypothermia.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15601275     DOI: 10.1111/j.1365-2044.2004.04033.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  14 in total

1.  Oximetry feedback flow control simulation for oxygen therapy.

Authors:  Mario G Iobbi; Anita K Simonds; Robert J Dickinson
Journal:  J Clin Monit Comput       Date:  2007-01-05       Impact factor: 2.502

2.  Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors.

Authors:  Nicolas Nesseler; Jean-Vincent Frénel; Yoann Launey; Jeff Morcet; Yannick Mallédant; Philippe Seguin
Journal:  Intensive Care Med       Date:  2012-08-07       Impact factor: 17.440

3.  Can the descending aortic stroke volume be estimated by transesophageal descending aortic photoplethysmography?

Authors:  Peng Ling; Gong Quan; Yu Siyuan; Gao Bo; Wei Wei
Journal:  J Anesth       Date:  2017-03-27       Impact factor: 2.078

4.  Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.

Authors:  Barak Pertzov; Elitsur Brachfeld; Avraham Unterman; Evgeni Gershman; Nader Abdel-Rahman; Dror Rosengarten; Mordechai Reuven Kramer
Journal:  Lung       Date:  2018-11-24       Impact factor: 2.584

5.  Measuring gas exchange with step changes in inspired oxygen: an analysis of the assumption of oxygen steady state in patients suffering from COPD.

Authors:  Lars P Thomsen; Ulla M Weinreich; Dan S Karbing; Peter D Wagner; Stephen E Rees
Journal:  J Clin Monit Comput       Date:  2014-10-02       Impact factor: 2.502

6.  A comparison of response time to desaturation between tracheal oximetry and peripheral oximetry.

Authors:  Li Wang; Wei Wei; Ming Gong; Ling Mu
Journal:  J Clin Monit Comput       Date:  2010-03-12       Impact factor: 2.502

7.  Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor.

Authors:  Jarkko Harju; Antti Vehkaoja; Ville Lindroos; Pekka Kumpulainen; Sasu Liuhanen; Arvi Yli-Hankala; Niku Oksala
Journal:  J Clin Monit Comput       Date:  2016-10-17       Impact factor: 2.502

8.  The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

Authors:  Ling Mou; Quan Gong; Wei Wei; Bo Gao
Journal:  J Clin Monit Comput       Date:  2013-03-10       Impact factor: 2.502

9.  Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

Authors:  Andrea Casati; Grazia Squicciarini; Marco Baciarello; Marta Putzu; Alessandra Salvadori; Guido Fanelli
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

10.  Evaluation of finger and forehead pulse oximeters during mild hypothermic cardiopulmonary bypass.

Authors:  Ken Yamaura; Kazuo Irita; Tadashi Kandabashi; Kohei Tohyama; Shosuke Takahashi
Journal:  J Clin Monit Comput       Date:  2007-06-20       Impact factor: 1.977

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.