Literature DB >> 31875167

Multiple-Input Multiple-Output (MIMO) MRI: Combining Parallel Excitation and Parallel Reception for Enhanced Imaging.

Xianglun Mao1, Nicole L Vike2, Thomas M Talavage3, Joseph V Rispoli4, David J Love1.   

Abstract

Magnetic resonance imaging (MRI) plays a critical role in visualizing the structure and functions of the human body. In order to accelerate imaging time and improve image quality, radio-frequency (RF) coil receive arrays are commonly employed to acquire the magnetic resonance (MR) signal. Similarly, multiple transmit coils have been shown to accelerate and refine RF excitation. In this work, we investigate the optimization of total imaging time and image accuracy when considering both the transmit and receive coil arrays; we term this strategy multiple-input multiple-output (MIMO) MRI. Our RF pulse design method is modeled by minimizing the excitation errors while simultaneously maximizing the signal-to-noise ratio (SNR) of the reconstructed MR image. It further allows a key tradeoff between the two optimizers. Additionally, multiple acceleration factors, varying numbers of receive coils used, maximum excitation error tolerance, and different excitation patterns are simulated and analyzed in this model. For a given excitation pattern, our method is shown to improve the SNR by 18-130% under certain acceleration schemes, as compared to conventional parallel transmission methods, while simultaneously controlling the excitation error within a desired scope (NRMSE ≤ 0.12).

Entities:  

Keywords:  MIMO; RF pulse design; SNR; acceleration factor; parallel excitation; parallel reception; quadratic optimization

Year:  2019        PMID: 31875167      PMCID: PMC6929686          DOI: 10.1109/tci.2019.2904882

Source DB:  PubMed          Journal:  IEEE Trans Comput Imaging


  24 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  A k-space analysis of small-tip-angle excitation. 1989.

Authors:  John Pauly; Dwight Nishimura; Albert Macovski
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

4.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  SENSE optimization of a transceive surface coil array for MRI at 4 T.

Authors:  Robert G Pinkerton; Graeme C McKinnon; Ravi S Menon
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

6.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

7.  Dependence of B1+ and B1- Field Patterns of Surface Coils on the Electrical Properties of the Sample and the MR Operating Frequency.

Authors:  Manushka V Vaidya; Christopher M Collins; Daniel K Sodickson; Ryan Brown; Graham C Wiggins; Riccardo Lattanzi
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-02-04       Impact factor: 1.176

Review 8.  Parallel MR imaging.

Authors:  Anagha Deshmane; Vikas Gulani; Mark A Griswold; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2012-07       Impact factor: 4.813

9.  Joint design of large-tip-angle parallel RF pulses and blipped gradient trajectories.

Authors:  Zhipeng Cao; Manus J Donahue; Jun Ma; William A Grissom
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

10.  Specific absorption rate studies of the parallel transmission of inner-volume excitations at 7T.

Authors:  Adam C Zelinski; Leonardo M Angelone; Vivek K Goyal; Giorgio Bonmassar; Elfar Adalsteinsson; Lawrence L Wald
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.