Literature DB >> 15534750

SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

Steve Langer1, Brian Bartholmai, Ken Fetterly, Scott Harmsen, William Ryan, Brad Erickson, Kathy Andriole, John Carrino.   

Abstract

The efficacy of two medical-grade, self-calibrating, gray scale displays were compared with regard to impact on sensitivity and specificity for the detection of interstitial lung disease (ILD) on computed radiographs (CR). The displays were a 5-megapixel (MP) cathode ray tube (CRT) device and a 3-MP liquid crystal display (LCD). A sample consisting of 230 anteroposterior (AP), posteroanterior (PA), and lateral views of the chest with CT-proven findings characteristic for ILD as well as 80 normal images were compared. This double-blinded trial produced a sample sufficient to detect if the sensitivity of the LCD was 10% or more reduced (one-sided) from the "gold standard" CRT display. Both displays were calibrated to the DICOM gray scale standard and the coefficient of variation of the luminance function varied less than 2% during the study. Five board-certified radiologists specializing in thoracic radiology interpreted the sample on both displays and the intraobserver Az (area under the ROC curve) showed no significant correlation to the display used. In addition, an interobserver kappa analysis showed that the relative disagreement between any observer pair remained relatively constant between displays, and thus was display invariant. This study demonstrated there is no significant change in observer performance sensitivity on 5-MP CRT versus 3-MP LCD displays for CR examinations demonstrating ILD of the chest.

Entities:  

Mesh:

Year:  2004        PMID: 15534750      PMCID: PMC3046602          DOI: 10.1007/s10278-004-1013-7

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  8 in total

1.  Chest radiography: comparison of high-resolution digital displays with conventional and digital film.

Authors:  G G Cox; L T Cook; J H McMillan; S J Rosenthal; S J Dwyer
Journal:  Radiology       Date:  1990-09       Impact factor: 11.105

2.  Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images.

Authors:  B S Slasky; D Gur; W F Good; M A Costa-Greco; K M Harris; L A Cooperstein; H E Rockette
Journal:  Radiology       Date:  1990-03       Impact factor: 11.105

3.  Comparative accuracy of high resolution computed tomography and chest radiography in the diagnosis of chronic diffuse infiltrative lung disease.

Authors:  S P Padley; D M Hansell; C D Flower; P Jennings
Journal:  Clin Radiol       Date:  1991-10       Impact factor: 2.350

4.  Chronic diffuse infiltrative lung disease: comparison of diagnostic accuracy of CT and chest radiography.

Authors:  J R Mathieson; J R Mayo; C A Staples; N L Müller
Journal:  Radiology       Date:  1989-04       Impact factor: 11.105

5.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach.

Authors:  E R DeLong; D M DeLong; D L Clarke-Pearson
Journal:  Biometrics       Date:  1988-09       Impact factor: 2.571

6.  Receiver operating characteristic analysis of fracture and pneumonia detection: comparison of laser-digitized workstation images and conventional analog radiographs.

Authors:  S J Ackerman; J N Gitlin; R W Gayler; C D Flagle; R N Bryan
Journal:  Radiology       Date:  1993-01       Impact factor: 11.105

7.  The measurement of observer agreement for categorical data.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-03       Impact factor: 2.571

8.  Interpretation of emergency department radiographs by radiologists and emergency medicine physicians: teleradiology workstation versus radiograph readings.

Authors:  W W Scott; D A Bluemke; W K Mysko; G E Weller; G D Kelen; R L Reichle; J C Weller; J N Gitlin
Journal:  Radiology       Date:  1995-04       Impact factor: 11.105

  8 in total
  5 in total

1.  Effect of greyscale liquid crystal displays of different resolutions on observer performance during detection of small solitary pulmonary nodules.

Authors:  J Yin; Q Guo; W Zhang; H Su; J Zhang; Y Yue; C Ding; A Lin; Y Wang; H Wang
Journal:  Br J Radiol       Date:  2012-06-27       Impact factor: 3.039

2.  The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs.

Authors:  H Usami; M Ikeda; T Ishigaki; H Fukushima; K Shimamoto
Journal:  Eur Radiol       Date:  2005-11-12       Impact factor: 5.315

3.  ROC study of four LCD displays under typical medical center lighting conditions.

Authors:  Steve Langer; Ken Fetterly; Jay Mandrekar; Scott Harmsen; Brian Bartholmai; Charles Patton; Alan Bishop; Colin McCannel
Journal:  J Digit Imaging       Date:  2006-03       Impact factor: 4.056

4.  Comparison of color LCD and medical-grade monochrome LCD displays in diagnostic radiology.

Authors:  Håkan Geijer; Mats Geijer; Lillemor Forsberg; Susanne Kheddache; Patrik Sund
Journal:  J Digit Imaging       Date:  2007-06       Impact factor: 4.056

5.  Influence of liquid crystal display monitors on observer performance for detection of diffuse pulmonary disease on chest radiographs.

Authors:  Hiromichi Fukushima; Mitsuru Ikeda; Takeo Ishigaki; Hisashi Usami; Kazuhiro Shimamoto
Journal:  Radiat Med       Date:  2007-06-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.