Literature DB >> 2389035

Chest radiography: comparison of high-resolution digital displays with conventional and digital film.

G G Cox1, L T Cook, J H McMillan, S J Rosenthal, S J Dwyer.   

Abstract

This study was performed to compare the performances of observers using three display formats for chest radiography. The display formats were conventional radiographs, digitized radiographs (2,048 X 2,048 X 12 bits) printed on laser film, and digitized radiographs (2,048 X 2,048 X 12 bits) displayed on a high-resolution (2,560 X 2,048 X 12-bit) gray-scale display. The test set for the study consisted of 163 cases. Sixty-four of the cases were normal, whereas the 99 remaining cases demonstrated one or more common radiographic abnormalities. Nine abnormalities were selected for analysis: costophrenic angle blunting, interstitial disease, atelectasis, pneumothorax, parenchymal mass, consolidation, obstructive disease, hilar/mediastinal mass, and apical scarring. Six experienced general radiologists participated in the evaluation. Receiver operating characteristic curves were generated for each abnormality and display format. The results indicate that, while the three display formats are equivalent for the detection of some abnormalities, detectable differences in observer performance may be seen even at 2,048 X 2,048 X 12 bits for the detection of obstructive disease, pneumothorax, interstitial disease, and parenchymal masses.

Entities:  

Mesh:

Year:  1990        PMID: 2389035     DOI: 10.1148/radiology.176.3.2389035

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  16 in total

1.  Enhancement of chest images by automatic adaptive spatial filtering.

Authors:  M Souto; J Correa; P G Tahoces; D Tucker; K S Malagari; J J Vidal; R G Fraser
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

2.  Design of a high-speed, high-resolution teleradiology network.

Authors:  B K Stewart; S J Dwyer; H Kangarloo
Journal:  J Digit Imaging       Date:  1992-08       Impact factor: 4.056

3.  Hardware and software requirements for a picture archiving and communication system's diagnostic workstations.

Authors:  D R Haynor; D V Smith; H W Park; Y Kim
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

4.  Should 3K zoom function be used for detection of pneumothorax in cesium iodide/amorphous silicon flat-panel detector radiographs presented on 1K-matrix soft copies?

Authors:  Karin A Herrmann; H M Bonél; A Stäbler; M Voelk; M Strotzer; C J Zech; M F Reiser
Journal:  Eur Radiol       Date:  2006-08-01       Impact factor: 5.315

5.  An ROC study of chest radiographs: 2K Versus 4K high-resolution soft-copy images.

Authors:  Su Young Kim; Yoon Joon Hwang; Yoon Hee Han; Jung Wook Seo; Ji Young Lee; Yong Hoon Kim; Soon Joo Cha; Gham Hur; Sung Soon Lee
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

6.  Comparison of a PACS workstation with laser hard copies for detecting scaphoid fractures in the emergency department.

Authors:  W Khaliq; C J Blakeley; S Maheshwaran; K Hashemi; P Redman
Journal:  J Digit Imaging       Date:  2008-11-07       Impact factor: 4.056

7.  Radiology services for remote communities: cost minimisation study of telemedicine.

Authors:  P A Halvorsen; I S Kristiansen
Journal:  BMJ       Date:  1996-05-25

8.  A digital imaging and communications in medicine (DICOM) print service for chest imaging.

Authors:  D M Tucker; C T Suitor; S J Shepard; D F Schomer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

Review 9.  Telemedicine effects: cost, quality, and access.

Authors:  R L Bashshur
Journal:  J Med Syst       Date:  1995-04       Impact factor: 4.460

Review 10.  Current status of domestic telemedicine.

Authors:  J Grigsby
Journal:  J Med Syst       Date:  1995-02       Impact factor: 4.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.