Literature DB >> 10627842

Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty.

S Patel1, J M McLaughlin.   

Abstract

PURPOSE: To measure and compare central corneal thickness (CT) and intraocular pressure (IOP) in keratoconus and post-keratoplasty subjects and examine the CT-IOP relationship.
METHODS: 22 keratoconus (category I: six female sixteen male, average age 27.0 range 12-47) and 19 post-keratoplasty (category II: ten female nine male average age 34.6 range 16-54) patients without other anterior segment conditions were recruited. Only one, non-contact lens wearing, eye of the patient was included for analysis. Cornea was anaesthetised with non-preserved 0.4% Benoxinate Hydrochloride. Using a randomised approach, CT was measured using a standard ultrasonic pachymeter. IOP was then measured using a standard Goldmann tonometer. At all times the tonometrist remained unaware of the corneal thickness values.
RESULTS: The mean (+/- s.d.) values for CT and IOP respectively in the two categories were: (I), 445 (45) mu and 9.8 (2.3) mmHg, (II), 564(44) microns and 15.8 (3.9) mmHg. Differences between I and II for both CT and IOP were significant (t-test, p = 0.01). Within each category, a significant correlation between CT and IOP was not found. Pooling all pairs of data (n = 41) a significant relationship between CT and IOP was detected (r = 0.635, p = 0.0001).
CONCLUSION: The results confirm the hypothesis that an eye with a thicker cornea tends to present with a higher measured IOP. In the management of keratoconus and other corneal surgical procedures, changes in CT will contribute to any apparent changes in measured IOP.

Entities:  

Mesh:

Year:  1999        PMID: 10627842     DOI: 10.1046/j.1475-1313.1999.00420.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  5 in total

Review 1.  [The risk of glaucoma and corneal thickness].

Authors:  A G Böhm
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

2.  The influence of corneal geometrical and biomechanical properties on tonometry readings in keratoconic eyes.

Authors:  Mustafa Değer Bilgeç; Eray Atalay; Ömer Sözer; Hüseyin Gürsoy; Muzaffer Bilgin; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2019-12-02       Impact factor: 2.031

3.  Comparison of iCare tonometer and Goldmann applanation tonometry in normal corneas and in eyes with automated lamellar and penetrating keratoplasty.

Authors:  M L Salvetat; M Zeppieri; F Miani; C Tosoni; L Parisi; P Brusini
Journal:  Eye (Lond)       Date:  2011-03-25       Impact factor: 3.775

4.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

5.  Association with Corneal Remodeling Related Genes, ALDH3A1, LOX, and SPARC Genes Variations in Korean Keratoconus Patients.

Authors:  Jee-Won Mok; Ha-Rim So; Min-Ji Ha; Kyung-Sun Na; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2021-02-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.