Literature DB >> 15487753

New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology.

Peter Schardt1, Josef Deuringer, Jörg Freudenberger, Erich Hell, Wolfgang Knüpfer, Detlef Mattern, Markus Schild.   

Abstract

The future demands of computed tomography imaging regarding the x-ray source can be summarized with higher scan power, shorter rotation times, shorter cool down times and smaller focal spots. We report on a new tube technology satisfying all these demands by making use of a novel cooling principle on one hand and of a novel beam control system on the other hand. Nowadays tubes use a rotating anode disk mainly cooled via radiation. The Straton x-ray tube is the first tube available for clinical routine utilizing convective cooling exclusively. It is demonstrated that this cooling principle makes large heat storage capacities of the anode disk obsolete. The unprecedented cooling rate of 4.8 MHU/min eliminates the need for waiting times due to anode cooling in clinical workflow. Moreover, an electronic beam deflection system for focal spot position and size control opens the door to advanced applications. The physical backgrounds are discussed and the technical realization is presented. From this discussion the superior suitability of this tube to withstand g-forces well above 20 g created by fast rotating gantries will become evident. Experience from a large clinical trial is reported and possible ways for future developments are discussed.

Mesh:

Year:  2004        PMID: 15487753     DOI: 10.1118/1.1783552

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography.

Authors:  Paul Deak; Marcel van Straten; Paul C Shrimpton; Maria Zankl; Willi A Kalender
Journal:  Eur Radiol       Date:  2007-12-08       Impact factor: 5.315

2.  Impact of the z-flying focal spot on resolution and artifact behavior for a 64-slice spiral CT scanner.

Authors:  Yiannis Kyriakou; Marc Kachelriess; Michael Knaup; Jens U Krause; Willi A Kalender
Journal:  Eur Radiol       Date:  2006-04-06       Impact factor: 5.315

3.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

Review 4.  Computed tomography--old ideas and new technology.

Authors:  Dominik Fleischmann; F Edward Boas
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

5.  Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system.

Authors:  Shuai Leng; Zhicong Yu; Ahmed Halaweish; Steffen Kappler; Katharina Hahn; Andre Henning; Zhoubo Li; John Lane; David L Levin; Steven Jorgensen; Erik Ritman; Cynthia McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-22

6.  Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture.

Authors:  V Bogdan Neculaes; Yun Zou; Peter Zavodszky; Louis Inzinna; Xi Zhang; Kenneth Conway; Antonio Caiafa; Kristopher Frutschy; William Waters; Bruno De Man
Journal:  Phys Plasmas       Date:  2014-04-28       Impact factor: 2.023

7.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

8.  Development and performance evaluation of the second model 256-detector row CT.

Authors:  Masahiro Endo; Shinichiro Mori; Susumu Kandatsu; Shuji Tanada; Chisato Kondo
Journal:  Radiol Phys Technol       Date:  2007-11-01

9.  Radiation dose estimates in dual-source computed tomography coronary angiography.

Authors:  Paul Stolzmann; Hans Scheffel; Thomas Schertler; Thomas Frauenfelder; Sebastian Leschka; Lars Husmann; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more