Literature DB >> 20821159

Development and performance evaluation of the second model 256-detector row CT.

Masahiro Endo1, Shinichiro Mori, Susumu Kandatsu, Shuji Tanada, Chisato Kondo.   

Abstract

Since our initial development of the 256-detector row CT scanner (256-row CT) for four-dimensional (4D) imaging of moving organs in 2003, the results of physical performance and those in animal and human studies have suggested that this scanner may be useful in the examination of moving organs such as the heart and lungs. We have now developed a second model of the 256-row CT with improved specifications, with a scan time of 0.5 s/rotation at the highest speed and real-time reconstruction and display of dynamic 3D images (4D images). Here, we investigated the image characteristics of the new model, including spatial resolution, noise, and low-contrast detectability, as well as the dose profile and its integral in stationary phantoms. One volunteer and one patient with lung cancer were scanned, and their images were evaluated. The results show that all characteristics have been improved compared with those of the first model, with a remarkable improvement in the low-contrast detectability and slice sensitivity profile. In a contrast study, coronary arteries were clearly visualized in the normal heart without electrocardiographic gating. Movement and deformation of the tumor in the patient with lung cancer was captured in a study of a single breath cycle. The second model 256-row CT with improved characteristics may be beneficial in imaging of moving organs such as the heart and lungs, and may enable cerebral perfusion studies of the whole brain.

Entities:  

Mesh:

Year:  2007        PMID: 20821159     DOI: 10.1007/s12194-007-0004-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  11 in total

Review 1.  Perfusion CT: a worthwhile enhancement?

Authors:  K A Miles; M R Griffiths
Journal:  Br J Radiol       Date:  2003-04       Impact factor: 3.039

2.  Noninvasive coronary artery imaging by multislice spiral computed tomography.

Authors:  Yuichi Sato; Katsuo Kanmatsuse; Fumio Inoue; Toshiyuki Horie; Masahiko Kato; Junji Kusama; Akihiro Yoshimura; Takako Imazeki; Satoru Furuhashi; Motoichiro Takahashi
Journal:  Circ J       Date:  2003-02       Impact factor: 2.993

3.  Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging.

Authors:  Shinichiro Mori; Masahiro Endo; Takanori Tsunoo; Susumu Kandatsu; Shuji Tanada; Hiroshi Aradate; Yasuo Saito; Hiroaki Miyazaki; Kazumasa Satoh; Satoshi Matsushita; Masahiro Kusakabe
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

4.  Evaluation of plaque texture by means of multislice computed tomography in patients with acute coronary syndrome and stable angina.

Authors:  Fumio Inoue; Yuichi Sato; Naoya Matsumoto; Shigemasa Tani; Takahisa Uchiyama
Journal:  Circ J       Date:  2004-09       Impact factor: 2.993

5.  Clinical potentials of the prototype 256-detector row CT-scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Kenya Murase; Hideaki Fujiwara; Kandatsu Susumu; Shuji Tanada
Journal:  Acad Radiol       Date:  2005-02       Impact factor: 3.173

6.  Volumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model.

Authors:  Shinichiro Mori; Takayuki Obata; Naoshi Nakajima; Nobutsune Ichihara; Masahiro Endo
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

7.  Real-time volumetric imaging of human heart without electrocardiographic gating by 256-detector row computed tomography: initial experience.

Authors:  Chisato Kondo; Shinichiro Mori; Masahiro Endo; Kiyoko Kusakabe; Naoki Suzuki; Asaki Hattori; Masahiro Kusakabe
Journal:  J Comput Assist Tomogr       Date:  2005 Sep-Oct       Impact factor: 1.826

8.  Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging.

Authors:  Shinichiro Mori; Masahiro Endo; Chisato Kondo; Shuji Tanada
Journal:  Acad Radiol       Date:  2006-06       Impact factor: 3.173

9.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking.

Authors:  Paul J Keall; Sarang Joshi; S Sastry Vedam; Jeffrey V Siebers; Vijaykumar R Kini; Radhe Mohan
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

10.  Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry.

Authors:  Shinichiro Mori; Masahiro Endo; Kanae Nishizawa; Takanori Tsunoo; Takahiko Aoyama; Hideaki Fujiwara; Kenya Murase
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

View more
  4 in total

Review 1.  Developments in neuroimaging for acute ischemic stroke: diagnostic and clinical trial applications.

Authors:  Amie W Hsia; Chelsea S Kidwell
Journal:  Curr Atheroscler Rep       Date:  2008-08       Impact factor: 5.113

2.  Positional dependence of the CT number with use of a cone-beam CT scanner for an electron density phantom in particle beam therapy.

Authors:  Yohsuke Kusano; Saki Uesaka; Kaori Yajima; Motoki Kumagai; Hideyuki Mizuno; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2012-12-16

3.  Water-equivalent pathlength reproducibility due to respiratory pattern variation in charged-particle pancreatic radiotherapy.

Authors:  Motoki Kumagai; Shinichiro Mori; Ryusuke Hara; Hiroshi Asakura; Riwa Kishimoto; Hirotoshi Kato; Shigeru Yamada; Susumu Kandatsu
Journal:  Radiol Phys Technol       Date:  2008-12-26

4.  The Essentials of Cardiac Computerized Tomography.

Authors:  Peter McKavanagh; Gerard Walls; Claire McCune; Jonathon Malloy; Mark T Harbinson; Peter A Ball; Patrick M Donnelly
Journal:  Cardiol Ther       Date:  2015-11-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.