Literature DB >> 15448935

[Intraoperative imaging with the ISO C(3D)].

M Wich1, N Spranger, A Ekkernkamp.   

Abstract

Computed tomography (CT) scanning is the gold standard for displaying and visualizing complex anatomic structures such as the calcaneus, pelvis, and spine, etc. In orthopedic surgery CT scanning is unfortunately not available in the OR where it would be highly effective if scans could be done prior to wound closure. The reasons are high costs, need for constructional changes in the OR, and additional staff (radiologic technologist), etc. For the first time the ISO C(3D) enables the surgeon to generate multiplanar reconstruction (MPR) pictures during surgery within an acceptable time frame at a reasonable price with a familiar instrument (a modified C-arm). Since February 2001 we have been able to use the ISO C(3D) in our hospital and meanwhile we have scanned 442 surgical sites including the calcaneus, cervical spine, and acetabulum, etc. The intraoperative scans revealed fracture gaps and steps, unsatisfactory fragment alignment, or incorrectly positioned implants, leading to an overall revision rate of 7.3%The ISO C(3D) is a first step towards a new future for bone visualization. The next steps will bring an increase in scan area and resolution, and the high-contrast pictures will be replaced by ones very similar to modern CT slices showing certain soft tissue structures.

Entities:  

Mesh:

Year:  2004        PMID: 15448935     DOI: 10.1007/s00104-004-0953-2

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  5 in total

1.  Optimization of contrast agent volume for helical CT in the diagnostic assessment of patients with severe and multiple injuries.

Authors:  Grit Rademacher; Dirk Stengel; Stefanie Siegmann; Jan Petersein; Sven Mutze
Journal:  J Comput Assist Tomogr       Date:  2002 Jan-Feb       Impact factor: 1.826

2.  [Computer-assisted, robot-assisted hip prosthesis--standard procedure or specialty indication?].

Authors:  C Geiger; P A Ostermann; A Ekkernkamp
Journal:  Z Arztl Fortbild Qualitatssich       Date:  2001-04

3.  3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D).

Authors:  M Heiland; D Schulze; G Adam; R Schmelzle
Journal:  Dentomaxillofac Radiol       Date:  2003-01       Impact factor: 2.419

4.  [Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

Authors:  D Kotsianos; C Rock; S Wirth; U Linsenmaier; R Brandl; T Fischer; E Euler; W Mutschler; K J Pfeifer; M Reiser
Journal:  Rofo       Date:  2002-01

5.  [Comparative study of the quality of C-arm based 3D imaging of the talus].

Authors:  E Euler; S Wirth; U Linsenmaier; W Mutschler; K J Pfeifer; A Hebecker
Journal:  Unfallchirurg       Date:  2001-09       Impact factor: 1.000

  5 in total
  11 in total

1.  [Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery].

Authors:  U Stöckle; B König; A Schäffler; T Zschernack; N P Haas
Journal:  Unfallchirurg       Date:  2006-01       Impact factor: 1.000

2.  [Drilling with 3D fluoroscopic navigation in osteonecrosis of the femoral condyle].

Authors:  M Citak; D Kendoff; T Stübig; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-05       Impact factor: 1.000

3.  [Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

Authors:  S Wirth; E Euler; D Kotsianos-Hermle; M Treitl; U Linsenmaier; K-J Pfeifer; M Reiser; W Mutschler
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

4.  [Fractures of the upper ankle].

Authors:  M Frank; K Bauwens; A Ekkernkamp
Journal:  Orthopade       Date:  2009-10       Impact factor: 1.087

5.  [Intraoperative 3D C-arm imaging. State of the art].

Authors:  J von Recum; K Wendl; B Vock; P A Grützner; J Franke
Journal:  Unfallchirurg       Date:  2012-03       Impact factor: 1.000

Review 6.  [The hybrid operating room. Home of high-end intraoperative imaging].

Authors:  F Gebhard; C Riepl; P Richter; A Liebold; H Gorki; R Wirtz; R König; F Wilde; A Schramm; M Kraus
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

7.  [The isocentric C-arm. Visualization of fracture reduction and screw position in the radius].

Authors:  R Meier; J Geerling; T Hüfner; M Kfuri; C Krettek
Journal:  Unfallchirurg       Date:  2011-07       Impact factor: 1.000

8.  Fracture surgery of the extremities with the intra-operative use of 3D-RX: a randomized multicenter trial (EF3X-trial).

Authors:  M Suzan H Beerekamp; Dirk Th Ubbink; Mario Maas; Jan Sk Luitse; Peter Kloen; Taco Jm Blokhuis; Michiel Jm Segers; Meir Marmor; Niels Wl Schep; Marcel Gw Dijkgraaf; J Carel Goslings
Journal:  BMC Musculoskelet Disord       Date:  2011-07-06       Impact factor: 2.362

9.  Early Weight Bearing of Calcaneal Fractures Treated by Intraoperative 3D-Fluoroscopy and Locked-Screw Plate Fixation.

Authors:  B Kienast; J Gille; C Queitsch; M M Kaiser; R Thietje; C Juergens; A P Schulz
Journal:  Open Orthop J       Date:  2009-08-27

10.  Intraoperative Three-Dimensional Imaging in Calcaneal Fracture Treatment.

Authors:  Heui-Chul Gwak; Jeon-Gyo Kim; Jung-Han Kim; Sang-Myung Roh
Journal:  Clin Orthop Surg       Date:  2015-11-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.