Literature DB >> 21710152

[The isocentric C-arm. Visualization of fracture reduction and screw position in the radius].

R Meier1, J Geerling, T Hüfner, M Kfuri, C Krettek.   

Abstract

In addition to conventional C-arms which can be used for intraoperative imaging, C-arm image amplifiers with an option for three-dimensional imaging (ISO-C3D) are available to visualize reduction of fragments and positions of implants. In ten cadaver wrists intra-articular steps and intra-articular screw positions were simulated. Images obtained by conventional two-dimensional C-arm image amplifier, computed tomography and ISO-C3D were evaluated by four investigators using a questionnaire. For 2D image amplifier scans the investigators rated the quantity of the articular steps correctly in 45%, incorrectly in 51% and were uncertain in 4%. Concerning CT scans these values were 57, 40 and 3%, respectively. With a slow 190° ISO-C3D mode the investigators rated the steps correctly in 47%, incorrectly in 44% and were uncertain in 9%. The positions of the tip of the screw were rated correctly for 2D scans in 56%, incorrectly in 40% and were uncertain in 4%. For CT screw positions were assessed correctly in 40%, incorrectly in 43% and were uncertain in 17%. For ISO-C3D in fast 190° mode the rating was correct in 59%, wrong in 30% and uncertain in 11%. In the slow Iso-C3D mode the results were inferior with correct assessment in 51%, wrong results in 36% and uncertain evaluation in 13%. In our cadaveric study, ISO-C3D scans have been found valuable for intraoperative controls of implant positions and assessment of intra-articular steps.

Entities:  

Mesh:

Year:  2011        PMID: 21710152     DOI: 10.1007/s00113-011-2008-8

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  22 in total

1.  [Intraoperative imaging with the ISO C(3D)].

Authors:  M Wich; N Spranger; A Ekkernkamp
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  [Intraoperative three-dimensional imaging with an isocentric mobile C-arm at the wrist].

Authors:  R Meier; M Kfuri; J Geerling; T Hüfner; H Krimmer; C Krettek
Journal:  Handchir Mikrochir Plast Chir       Date:  2005-08       Impact factor: 1.018

3.  Intraoperative three-dimensional imaging with a motorized mobile C-arm (SIREMOBIL ISO-C-3D) in foot and ankle trauma care: a preliminary report.

Authors:  Martinus Richter; Jens Geerling; Stefan Zech; Thomas Goesling; Christian Krettek
Journal:  J Orthop Trauma       Date:  2005-04       Impact factor: 2.512

4.  Do Kirschner wires maintain reduction of displaced Colles' fractures?

Authors:  Tristan Barton; Charles Chambers; Emma Lane; Gordon Bannister
Journal:  Injury       Date:  2005-10-27       Impact factor: 2.586

5.  [3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography].

Authors:  D Kotsianos; C Rock; E Euler; S Wirth; U Linsenmaier; R Brandl; W Mutschler; K J Pfeifer
Journal:  Unfallchirurg       Date:  2001-09       Impact factor: 1.000

6.  The risk of adverse outcomes in extra-articular distal radius fractures is increased with malalignment in patients of all ages but mitigated in older patients.

Authors:  Ruby Grewal; Joy C MacDermid
Journal:  J Hand Surg Am       Date:  2007-09       Impact factor: 2.230

7.  3D imaging with an isocentric mobile C-arm comparison of image quality with spiral CT.

Authors:  Dorothea Kotsianos; Stefan Wirth; Tanja Fischer; Ekkehard Euler; Clemens Rock; Ulrich Linsenmaier; Klaus Jürgen Pfeifer; Maximilian Reiser
Journal:  Eur Radiol       Date:  2004-04-01       Impact factor: 5.315

8.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

9.  [Incorrect classification of extra-articular distal radius fractures by conventional X-rays. Comparison between biplanar radiologic diagnostics and CT assessment of fracture morphology].

Authors:  H C Dahlen; W M Franck; G Sabauri; M Amlang; H Zwipp
Journal:  Unfallchirurg       Date:  2004-06       Impact factor: 1.000

10.  [Value of 3D CT in diagnosis and treatment of fractures of the tibial plateau].

Authors:  P F Blaser; S Wicky; O Husmann; R A Meuli; P F Leyvraz
Journal:  Swiss Surg       Date:  1998
View more
  2 in total

1.  [Treatment of distal radius fractures. Percutaneous Kirschner-wires or palmar locking plates?].

Authors:  R Meier; C Krettek; C Probst
Journal:  Unfallchirurg       Date:  2012-07       Impact factor: 1.000

Review 2.  [Intraoperative 3D imaging : Diagnostic accuracy and therapeutic benefits].

Authors:  D Stengel; M Wich; A Ekkernkamp; N Spranger
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.