Literature DB >> 11793290

[Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

D Kotsianos1, C Rock, S Wirth, U Linsenmaier, R Brandl, T Fischer, E Euler, W Mutschler, K J Pfeifer, M Reiser.   

Abstract

PURPOSE: To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR).
METHOD: Human knee specimens (n = 22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Müller AO classification. To confirm the results, the specimens were finally surgically dissected.
RESULTS: 97 % of the tibial condylar fractures were easily seen and correctly classified according to the Müller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR.
CONCLUSION: The evaluation of fractures with the ISO-C is better than with plain films alone and comparable to CT scans. The three-dimensional reconstruction of the ISO-C can provide important information which cannot be obtained from plain films. The ISO-C-3D may be useful in planning operative reconstructions and evaluating surgical results in orthopaedic surgery of the limbs.

Entities:  

Mesh:

Year:  2002        PMID: 11793290     DOI: 10.1055/s-2002-19549

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  12 in total

1.  [Intraoperative imaging with the ISO C(3D)].

Authors:  M Wich; N Spranger; A Ekkernkamp
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Authors:  D Briem; W Linhart; W Lehmann; P G Begemann; G Adam; U Schumacher; D M Cullinane; J M Rueger; J Windolf
Journal:  Eur Spine J       Date:  2005-07-12       Impact factor: 3.134

3.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

Review 4.  [Precision in orthopaedic computer navigation].

Authors:  T Hüfner; D Kendoff; M Citak; J Geerling; C Krettek
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

5.  [The clinical use of the ISO-C(3D) imaging system in calcaneus fracture surgery].

Authors:  A Rübberdt; R Feil; D Stengel; N Spranger; S Mutze; M Wich; A Ekkernkamp
Journal:  Unfallchirurg       Date:  2006-02       Impact factor: 1.000

6.  [Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

Authors:  S Wirth; E Euler; D Kotsianos-Hermle; M Treitl; U Linsenmaier; K-J Pfeifer; M Reiser; W Mutschler
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

7.  [Multiplanar reconstruction with mobile 3D image intensifier. Surgical treatment of proximal humerus fractures].

Authors:  P Hepp; J Theopold; J-S Jarvers; B Marquaß; N von Dercks; C Josten
Journal:  Unfallchirurg       Date:  2014-05       Impact factor: 1.000

8.  3D imaging with an isocentric mobile C-arm comparison of image quality with spiral CT.

Authors:  Dorothea Kotsianos; Stefan Wirth; Tanja Fischer; Ekkehard Euler; Clemens Rock; Ulrich Linsenmaier; Klaus Jürgen Pfeifer; Maximilian Reiser
Journal:  Eur Radiol       Date:  2004-04-01       Impact factor: 5.315

9.  [Radiation exposure and 3 dimensional imaging options of SIREMOBIL Iso-C(3D) for planning surgical dental interventions].

Authors:  M Heiland; D Schulze; S Flinzberg; H Thurmann; U Rother; R Schmelzle
Journal:  Mund Kiefer Gesichtschir       Date:  2004-01-22

10.  Fracture surgery of the extremities with the intra-operative use of 3D-RX: a randomized multicenter trial (EF3X-trial).

Authors:  M Suzan H Beerekamp; Dirk Th Ubbink; Mario Maas; Jan Sk Luitse; Peter Kloen; Taco Jm Blokhuis; Michiel Jm Segers; Meir Marmor; Niels Wl Schep; Marcel Gw Dijkgraaf; J Carel Goslings
Journal:  BMC Musculoskelet Disord       Date:  2011-07-06       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.