Literature DB >> 3173170

Design and evaluation of a new reflectance pulse oximeter sensor.

Y Mendelson1, J C Kent, B L Yocum, M J Birle.   

Abstract

The design and construction of a new optical reflectance sensor suitable for noninvasive monitoring of arterial hemoglobin oxygen saturation with a pulse oximeter is described. The reflectance sensor was interfaced to a Datascope ACCUSAT pulse oximeter that was specially adapted for this study to perform as a reflectance oximeter. We evaluated the reflectance sensor in a group of 10 healthy adult volunteers. SpO2 obtained from the forehead with the reflectance pulse oximeter and SpO2 obtained from a finger sensor that was connected to a standard ACCUSAT transmittance pulse oximeter were compared simultaneously to arterial blood samples analyzed by an IL 282 CO-Oximeter. The equation for the best fitted linear regression line between the reflectance SpO2 and HbO2 values obtained from the reference IL 282 CO-Oximeter in the range between 62 and 100% was: SpO2 (%) = 4.78 +/- 0.96 (IL); n = 110. The regression analysis revealed a high degree of correlation (r = 0.98) and a relatively small standard error of the estimate (SEE = 1.82%). The mean and standard deviations for the difference between the reflectance SpO2 and IL 282 measurements was 1.38 and 1.85%, respectively. This study demonstrates the ability to acquire accurate SpO2 from the forehead using a reflectance sensor and a pulse oximeter.

Entities:  

Mesh:

Year:  1988        PMID: 3173170

Source DB:  PubMed          Journal:  Med Instrum        ISSN: 0090-6689


  8 in total

1.  Reflectance pulse oximetry--principles and obstetric application in the Zurich system.

Authors:  V König; R Huch; A Huch
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

2.  Reflection and transmission pulse oximetry during compromised peripheral perfusion.

Authors:  H Pälve
Journal:  J Clin Monit       Date:  1992-01

3.  Evaluation of a new reflectance pulse oximeter for clinical applications.

Authors:  Y Shimada; K Nakashima; Y Fujiwara; T Komatsu; M Kawanishi; J Takezawa; S Takatani
Journal:  Med Biol Eng Comput       Date:  1991-09       Impact factor: 2.602

Review 4.  Basic principles of optical radiation and some common applications in anesthesia.

Authors:  D Gravenstein; S Lampotang; W Huda; A Sultan
Journal:  J Clin Monit       Date:  1996-11

5.  Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.

Authors:  S Takatani; C Davies; N Sakakibara; A Zurick; E Kraenzler; L R Golding; G P Noon; Y Nose; M E DeBakey
Journal:  J Clin Monit       Date:  1992-10

6.  Intraoperative reflectance oximetry in burn patients.

Authors:  R L Sheridan; K M Prelack; L M Petras; S K Szyfelbein; R G Tompkins
Journal:  J Clin Monit       Date:  1995-01

7.  Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.

Authors:  Y Mendelson; M J McGinn
Journal:  J Clin Monit       Date:  1991-01

8.  The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare.

Authors:  Hyun Jae Baek; JaeWook Shin; Jaegeol Cho
Journal:  J Healthc Eng       Date:  2018-10-21       Impact factor: 2.682

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.