Literature DB >> 24145505

Hader bar and clip attachment retained mandibular complete denture.

Kunwarjeet Singh1, Nidhi Gupta, Vikram Kapoor, Ridhimaa Gupta.   

Abstract

Bar and clip attachments significantly improve the level of satisfaction of denture-wearing patients by enhancing the retention and stability of the prosthesis. These attachments have been most commonly used for connecting the prosthesis to implants, but they can be effectively used to retain tooth-supported prosthesis as well. The primary functions of bar attachments are splinting the abutments together, even distribution of forces to the abutments and supporting areas, guiding the prosthesis into place, improving the retention, stability, support and comfort of the patient. The primary requirement for the use of bar attachments is the availability of sufficient vertical and buccolingual space for the proper placement of the bar, sleeves, teeth arrangement and sufficient thickness of acrylic denture base to minimise incidence of denture fracture in the area of bar assembly.

Entities:  

Mesh:

Year:  2013        PMID: 24145505      PMCID: PMC3822056          DOI: 10.1136/bcr-2013-010401

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  5 in total

1.  Special technique for attachment incorporation with an implant overdenture.

Authors:  Walid M Sadig
Journal:  J Prosthet Dent       Date:  2003-01       Impact factor: 3.426

2.  A simple, predictable intraoral technique for retentive mechanism attachment of implant overdenture attachments.

Authors:  Tony Daher
Journal:  J Prosthodont       Date:  2003-09       Impact factor: 2.752

3.  Problems with prostheses on implants: a retrospective study.

Authors:  J N Walton; M I MacEntee
Journal:  J Prosthet Dent       Date:  1994-03       Impact factor: 3.426

4.  The service life of implant-retained overdenture attachment systems.

Authors:  Monica Nogueira Pigozzo; Marcelo Ferraz Mesquita; Guilherme Elias Pessanha Henriques; Luis Geraldo Vaz
Journal:  J Prosthet Dent       Date:  2009-08       Impact factor: 3.426

5.  Retention force and fatigue strength of overdenture attachment systems.

Authors:  D M Botega; M F Mesquita; G E P Henriques; L G Vaz
Journal:  J Oral Rehabil       Date:  2004-09       Impact factor: 3.837

  5 in total
  2 in total

1.  [Clinical application of mandibular overdenture supported by a two-implant and interforaminal bar in an edentulous atrophic mandible].

Authors:  Dao Li; Xiao Xue; Wang Xiaodong; Zhao Ke
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-08-01

2.  A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Authors:  Małgorzata Idzior-Haufa; Agnieszka A Pilarska; Wiesław Hędzelek; Piotr Boniecki; Krzysztof Pilarski; Barbara Dorocka-Bobkowska
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.