Literature DB >> 10794221

The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group.

A J Tonino1, A I Rahmy.   

Abstract

A proximally hydroxyapatite (HA)-coated hip prosthesis designed for proximal stem bonding and stress transfer was studied in a consecutive series of 398 patients in an ongoing, prospective multicenter study. Follow-up was 5 to 7 years. The clinical results were excellent with a mean preoperative Merle d'Aubigné score of 8.5 and 17.3 at 5 years. Only mild thigh pain not necessitating analgesics or a walking stick was reported in 3.6% at 5 years. Three cups and 3 stems had to be revised, all before the 2-year assessment and mainly for technical reasons. No components needed revision after 2 years. The 5-year HA-coated component survival was 99.2%. Serial radiographs showed excellent osseointegration, which was independent of pre-existing bone stock. The rate of radiographic bone remodeling was highest during the first 3 years, and positive bone remodeling (bone formation) preceded negative bone remodeling (bone resorption). The concept of transitional load transfer from proximal to distal could be acknowledged, with proximal load transfer highest in 77%. The combination of anatomic stem design with distal overreaming and proximal HA coating was thought to be the reason for these excellent results. Proximal circumferential osseointegration seems to be real because no linear or distal osteolysis was observed.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10794221     DOI: 10.1016/s0883-5403(00)90486-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

2.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

3.  Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty.

Authors:  T Gosens; E J van Langelaan
Journal:  Int Orthop       Date:  2005-05-18       Impact factor: 3.075

4.  Ten-year follow-up of an anatomical hydroxyapatite-coated total hip prosthesis.

Authors:  V Canales Cortés; J J Panisello Sebastiá; A Herrera Rodríguez; A Peguero Bona; A Martínez Martín; L Herrero Barcos; L García-Dihinx
Journal:  Int Orthop       Date:  2006-02-28       Impact factor: 3.075

5.  Preoperative bone quality as a factor in dual-energy X-ray absorptiometry analysis comparing bone remodelling between two implant types.

Authors:  Bart Cornelis Hendrikus van der Wal; Ali Rahmy; Bernd Grimm; Ide Heyligers; Alphons Tonino
Journal:  Int Orthop       Date:  2006-11-04       Impact factor: 3.075

6.  Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study.

Authors:  Jörg Axel Karl Ohnsorge; Jack Davis; Uwe Maus; Muharrem Saklak; Markus Weisskopf; Dieter Christian Wirtz
Journal:  HSS J       Date:  2006-09

7.  THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis.

Authors:  P N Baker; I A McMurtry; G Chuter; A Port; J Anderson
Journal:  Clin Orthop Relat Res       Date:  2010-07       Impact factor: 4.176

8.  Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems.

Authors:  B C H van der Wal; M Vischjager; B Grimm; I C Heyligers; A J Tonino
Journal:  Int Orthop       Date:  2005-06-01       Impact factor: 3.075

9.  Is the bone-bonding ability of a cementless total hip prosthesis enhanced by alkaline and heat treatments?

Authors:  Kazutaka So; Ayumi Kaneuji; Tadami Matsumoto; Shuichi Matsuda; Haruhiko Akiyama
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

10.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

View more