Literature DB >> 10463725

Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis. A follow-up of 94 consecutive arthroplasties.

M Røkkum1, M Brandt, K Bye, K R Hetland, S Waage, A Reigstad.   

Abstract

We have followed up for a period of seven to nine years 100 consecutive arthroplasties of the hip in which an entirely HA-coated implant had been used. The clinical results were excellent and bony incorporation was extensive in all components. No stem became loose or subsided but five cups were revised because of loosening after 3.8 to 5.5 years, having functioned painlessly and shown radiological ingrowth. Revision procedures because of excessive polyethylene wear have been performed on 18 hips and are planned for six more. Two eroded metal backings with worn-through polyethylene were exchanged; six hips showed metallosis without polyethylene wear-through. There were two cases of granulomatous cysts in the groin and 66 hips had osteolysis located periarticularly, in the greater trochanter or in the acetabulum.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10463725     DOI: 10.1302/0301-620x.81b4.8715

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Long-term follow-up (11 years plus) results of JRI (Furlong) total hip arthroplasty in young patients: cause for concern regarding acetabular cup?

Authors:  D K Sharma; Stuart Brooks
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

2.  Does a titanium-coated polyethylene press-fit cup give reliable midterm results?

Authors:  Nikki Hooper; Harry Sargeant; Chris Frampton; Gary Hooper
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

3.  An in vivo evaluation of bone response to three implant surfaces using a rabbit intramedullary rod model.

Authors:  Juan C Hermida; Arnie Bergula; Fred Dimaano; Monica Hawkins; Clifford W Colwell; Darryl D D'Lima
Journal:  J Orthop Surg Res       Date:  2010-08-16       Impact factor: 2.359

4.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

5.  Clinical biomechanics of wear in total hip arthroplasty.

Authors:  John J Callaghan; Douglas R Pedersen; Richard C Johnston; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2003

6.  Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.

Authors:  Maiken Stilling; Ole Rahbek; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-03-28       Impact factor: 4.176

7.  Severe Periprosthetic Metallosis and Polyethylene Liner Failure Complicating Total Hip Replacement: The Cloud Sign.

Authors:  Amir Paydar; Felix S Chew; Paul A Manner
Journal:  Radiol Case Rep       Date:  2015-12-07

8.  Fracture of the Neck of a Modern Cementless, Titanium Femoral Stem.

Authors:  Emmanuel Gibon; Justin T Deen
Journal:  Arthroplast Today       Date:  2020-05-11

9.  Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry.

Authors:  Kristian Horsager; Frank Madsen; Anders Odgaard; Claus Fink Jepsen; Lone Rømer; Per Wagner Kristensen; Bart L Kaptein; Kjeld Søballe; Maiken Stilling
Journal:  Acta Orthop       Date:  2018-12-10       Impact factor: 3.717

10.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

View more