Literature DB >> 11742472

Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up.

A M Claus1, C J Sychterz, R H Hopper, C A Engh.   

Abstract

In this retrospective study, we analyzed the formation of osteolysis with 2 cementless cups to evaluate if surface holes in metal shells influence the radiographic pattern of osteolysis. At a minimum of 10 years' follow-up, serial radiographs of 112 hips with Arthropor cups (having multiple shell holes) and 126 hips with Anatomic Medullary Locking (AML) cups (with no holes) were reviewed. Despite differences in variables other than cup design that can affect polyethylene wear and osteolysis rates, the incidence of osteolysis between the groups was coincidentally similar (47.3%, Arthropor; 47.6%, AML). The time of onset of osteolysis (mean, 7.5 and 7.4 years) also was similar. The radiographic pattern of the osteolytic lesions, which is largely a factor of cup design, differed. The Arthropor group had significantly larger lesions in Charnley zone I and significantly more hips with retroacetabular lesions (Charnley zones I and II); however, these lesions did not compromise cup stability. Patients with AML cups had more and larger lesions in the greater trochanter.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11742472     DOI: 10.1054/arth.2001.28365

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Cementless acetabular component inserted without screws - the effect of immediate weight-bearing.

Authors:  F Y Ng; Y Zhu; K Y Chiu
Journal:  Int Orthop       Date:  2006-08-19       Impact factor: 3.075

2.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

5.  Is tartrate-resistant acid phosphatase 5b a potent bio-marker for late stage aseptic implant loosening?

Authors:  Gerrit Steffen Maier; Christian Eberhardt; Marco Strauch; Konstantinos Kafchitsas; Andreas A Kurth
Journal:  Int Orthop       Date:  2014-08-01       Impact factor: 3.075

6.  Acetabular components with or without screws in total hip arthroplasty.

Authors:  Murad Pepe; Onur Kocadal; Tamer Erener; Kubilay Ceritoglu; Ertugrul Aksahin; Cem Nuri Aktekin
Journal:  World J Orthop       Date:  2017-09-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.