Monte Carlo computation of dosimetric amorphous silicon electronic portal images.

Jeffrey V Siebers1, Jong Oh Kim, Lung Ko, Paul J Keall, Radhe Mohan.   

Abstract

This study develops and tests a method to compute dosimetric images for an amorphous silicon (a-Si) flat-panel detector so that an accurate quantitative comparison between measured and computed portal images may be made. An EGS4-based Monte Carlo (MC) algorithm is developed to efficiently tally the energy deposition through the use of a virtual detector dose-scoring methodology. The complete geometry of the a-Si imager is utilized in the MC calculation up to the imager rear housing, which is replaced with a uniform thickness material slab. The detector-mounting hardware is modeled as a uniform backscattering material. The amount of backscatter material required to reproduce the measured backscatter is 0.98 g/cm2 of water. A flood-field irradiation, performed in the measurement imaging session, is used to cross-calibrate the computed images with the measured images. Calibrated MC-computed images reproduce measured field-size dependencies of the electronic portal imaging device (EPID) response to within <1%, without the need for optical glare or other empirical corrections. A 10% dose difference between measured and computed images was observed outside the field edge for a 10 x 10 cm2 field that was entirely blocked by the multileaf collimator (MLC). However, this error corresponded with less than 0.15% of the open-field dose. For 10 x 10 cm2 fields produced by 5 and 20 mm dynamically sweeping MLC gaps, more than 98% of the points were found to have a gamma less than one with a 2%, 2 mm criteria. For an intensity modulated radiation therapy (IMRT) patient test field, over 99% of the points were found to have a gamma less than one with a 2%, 2 mm criteria. This study demonstrates that MC can be an effective tool for predicting measured a-Si portal images and may be useful for IMRT EPID-based dosimetry.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15305468     DOI: 10.1118/1.1764392

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry.

Authors:  A J Vinall; A J Williams; V E Currie; A Van Esch; D Huyskens
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

2.  Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT.

Authors:  Inhwan Jason Yeo; Jae Won Jung; Baldev Patyal; Anant Mandapaka; Byong Yong Yi; Jong Oh Kim
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Monte Carlo-based adaptive EPID dose kernel accounting for different field size responses of imagers.

Authors:  Song Wang; Joseph K Gardner; John J Gordon; Weidong Li; Luke Clews; Peter B Greer; Jeffrey V Siebers
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

4.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

5.  Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

Authors:  Inhwan Jason Yeo; Jae Won Jung; Byong Yong Yi; Jong Oh Kim
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

6.  Rapid Monte Carlo simulation of detector DQE(f).

Authors:  Josh Star-Lack; Mingshan Sun; Andre Meyer; Daniel Morf; Dragos Constantin; Rebecca Fahrig; Eric Abel
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

7.  An empirical calibration method for an a-Si portal imaging device: applications in pretreatment verification of IMRT.

Authors:  L Conte; C Mordacchini; L Pozzi; C Vite
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

8.  A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance.

Authors:  Mengying Shi; Marios Myronakis; Yue-Houng Hu; Daniel Morf; Joerg Rottmann; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-08-20       Impact factor: 3.609

9.  Dose-guided radiotherapy for lung tumors.

Authors:  Angelo Piermattei; Andrea Fidanzio; Savino Cilla; Francesca Greco; Luigi Azario; Domenico Sabatino; Mattia Grusio; Mariella Cozzolino; Vincenzo Fusco
Journal:  Med Biol Eng Comput       Date:  2009-12-10       Impact factor: 2.602

10.  Transit dosimetry in dynamic IMRT with an a-Si EPID.

Authors:  Mahsheed Sabet; Pejman Rowshanfarzad; Fred W Menk; Peter B Greer
Journal:  Med Biol Eng Comput       Date:  2014-05-31       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.