Literature DB >> 15236362

Accelerating cardiac cine 3D imaging using k-t BLAST.

Sebastian Kozerke1, Jeffrey Tsao, Reza Razavi, Peter Boesiger.   

Abstract

By exploiting spatiotemporal correlations in cardiac acquisitions using k-t BLAST, gated cine 3D acquisitions of the heart were accelerated by a net factor of 4.3, making single breathhold acquisitions possible. Sparse sampling of k-t space along a sheared grid pattern was implemented into a cine 3D SSFP sequence. The acquisition of low-resolution training data, which was required to resolve aliasing in the k-t BLAST method, was either interleaved into the sampling process or obtained in a separate prescan to allow for shorter breathhold durations in patients with heart disease. Volumetric datasets covering the heart with 20 slices at a spatial resolution of 2 x 2 x 5 mm3 were recorded with 20 cardiac phases in a total breathhold duration of 25-27 sec, or 18 sec if partial Fourier sampling was additionally employed. The feasibility of the method was demonstrated on healthy volunteers and on patients. The comparison of endocardial area derived from single slices of the 3D dataset with values extracted from separate single-slice acquisitions showed no significant differences. By shortening the acquisition substantially, k-t BLAST may greatly facilitate volumetric imaging of the heart for evaluation of regional wall motion and the assessment of ventricular volume and ejection fraction. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15236362     DOI: 10.1002/mrm.20145

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI.

Authors:  Dana C Peters; Daniel B Ennis; Pratik Rohatgi; Mushabbar A Syed; Elliot R McVeigh; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

2.  Accelerated dynamic Fourier velocity encoding by exploiting velocity-spatio-temporal correlations.

Authors:  Michael S Hansen; Christof Baltes; Jeffrey Tsao; Sebastian Kozerke; Klaas P Pruessmann; Peter Boesiger; Erik M Pedersen
Journal:  MAGMA       Date:  2004-11-09       Impact factor: 2.310

3.  Assessment of functional anatomy of the mitral valve in patients with mitral regurgitation with cine magnetic resonance imaging: comparison with transesophageal echocardiography and surgical results.

Authors:  A Stork; O Franzen; H Ruschewski; C Detter; K Müllerleile; P M Bansmann; G Adam; G K Lund
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

4.  Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T.

Authors:  Daniel Jeong; Mark L Schiebler; Peng Lai; Kang Wang; Karl K Vigen; Christopher J François
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-14       Impact factor: 2.357

5.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

6.  Influence of principal component analysis acceleration factor on velocity measurement in 2D and 4D PC-MRI.

Authors:  Gwenaël Pagé; Jérémie Bettoni; Anne-Virginie Salsac; Olivier Balédent
Journal:  MAGMA       Date:  2018-01-22       Impact factor: 2.310

7.  Compressed sensing reconstruction for whole-heart imaging with 3D radial trajectories: a graphics processing unit implementation.

Authors:  Seunghoon Nam; Mehmet Akçakaya; Tamer Basha; Christian Stehning; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

8.  Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation.

Authors:  Mehdi H Moghari; Ashita Barthur; Maria E Amaral; Tal Geva; Andrew J Powell
Journal:  Magn Reson Med       Date:  2017-12-08       Impact factor: 4.668

9.  Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA?

Authors:  A Le Bras; H Raoult; J-C Ferré; T Ronzière; J-Y Gauvrit
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

10.  2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition.

Authors:  Dana C Peters; Reza Nezafat; Holger Eggers; Christian Stehning; Warren J Manning
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.