Literature DB >> 25680356

Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T.

Daniel Jeong1, Mark L Schiebler, Peng Lai, Kang Wang, Karl K Vigen, Christopher J François.   

Abstract

Validation of a new single breath-hold, three-dimensional, cine balanced steady-state free precession (3D cine bSSFP) cardiac magnetic resonance (CMR) sequence for left ventricular function. CMR examinations were performed on fifteen patients and three healthy volunteers on a clinical 1.5T scanner using a two-dimensional (2D) cine balanced SSFP CMR sequence (2D cine bSSFP) followed by an investigational 3D cine bSSFP pulse sequence acquired within a single breath hold. Left ventricular end diastolic volume (LVEDV), end systolic volume (LVESV), ejection fraction (LVEF), and myocardial mass were independently segmented on a workstation by two experienced radiologists. Blood pool to myocardial contrast was evaluated in consensus using a Likert scale. Bland-Altman analysis was used to compare these quantitative and nominal measurements for the two sequences. The average acquisition time was significantly shorter for the 3D cine bSSFP than for 2D cine bSSFP (0.36 ± 0.03 vs. 8.5 ± 2.3 min) p = 0.0002. Bland-Altman analyses [bias and (limits of agreement)] of the data derived from these two methods revealed that the LVEF 0.9% (-4.7, 6.4), LVEDV 4.9 ml (-23.0, 32.8), LVESV -0.2 ml (-22.4, 21.9), and myocardial mass -0.4 g (-23.8, 23.0) were not significantly different. There was excellent intraclass correlation for intra-observer variability (0.981, 0.989, 0.997, 0.985) and inter-observer variability (0.903, 0.954, 0.970, 0.842) for LVEF, LVEDV, LVESV, and myocardial mass respectively. 3D cine bSSFP allows for accurate single breath-hold volumetric cine CMR which enables substantial improvements in scanner time efficiency without sacrificing diagnostic accuracy.

Entities:  

Mesh:

Year:  2015        PMID: 25680356     DOI: 10.1007/s10554-015-0615-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  14 in total

1.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

2.  Accelerating cardiac cine 3D imaging using k-t BLAST.

Authors:  Sebastian Kozerke; Jeffrey Tsao; Reza Razavi; Peter Boesiger
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

3.  Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: comparison with two-dimensional cine imaging.

Authors:  Yasuo Amano; Yuriko Suzuki; Marc van Cauteren
Journal:  Comput Med Imaging Graph       Date:  2007-11-05       Impact factor: 4.790

4.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

5.  Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging.

Authors:  Steffen Huber; Raja Muthupillai; Hamid Mojibian; Benjamin Cheong; Marc Kouwenhoven; Scott D Flamm
Journal:  Magn Reson Imaging       Date:  2008-05-16       Impact factor: 2.546

6.  Volumetric cardiac quantification by using 3D dual-phase whole-heart MR imaging.

Authors:  Sergio Uribe; Tarinee Tangchaoren; Victoria Parish; Ivo Wolf; Reza Razavi; Gerald Greil; Tobias Schaeffter
Journal:  Radiology       Date:  2008-06-23       Impact factor: 11.105

7.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

8.  Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST Technique.

Authors:  Carlos Eduardo Rochitte; Clerio F Azevedo; Miguel A Rosário; Maria H R Siqueira; Victor Monsão; Manoj Saranathan; Thomas K Foo; Roberto Kalil Filho; Giovanni G Cerri; José A F Ramires
Journal:  Open Cardiovasc Med J       Date:  2011-03-22

9.  Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique--comparison of an intravascular and extravascular contrast agent.

Authors:  Marcus R Makowski; Andrea J Wiethoff; Christian H P Jansen; Sergio Uribe; Victoria Parish; Andreas Schuster; Rene M Botnar; Aaron Bell; Christoph Kiesewetter; Reza Razavi; Tobias Schaeffter; Gerald F Greil
Journal:  J Cardiovasc Magn Reson       Date:  2012-07-31       Impact factor: 5.364

10.  Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE.

Authors:  Neil Maredia; Sebastian Kozerke; Abdul Larghat; Nik Abidin; John P Greenwood; Peter Boesiger; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2008-05-28       Impact factor: 5.364

View more
  7 in total

Review 1.  Cardiovascular imaging 2015 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2016-05       Impact factor: 2.357

2.  Deep learning based fully automatic segmentation of the left ventricular endocardium and epicardium from cardiac cine MRI.

Authors:  Yan Wang; Yue Zhang; Zhaoying Wen; Bing Tian; Evan Kao; Xinke Liu; Wanling Xuan; Karen Ordovas; David Saloner; Jing Liu
Journal:  Quant Imaging Med Surg       Date:  2021-04

3.  Value CMR: Towards a Comprehensive, Rapid, Cost-Effective Cardiovascular Magnetic Resonance Imaging.

Authors:  El-Sayed H Ibrahim; Luba Frank; Dhiraj Baruah; V Emre Arpinar; Andrew S Nencka; Kevin M Koch; L Tugan Muftuler; Orhan Unal; Jadranka Stojanovska; Jason C Rubenstein; Sherry-Ann Brown; John Charlson; Elizabeth M Gore; Carmen Bergom
Journal:  Int J Biomed Imaging       Date:  2021-05-15

4.  Clinical evaluation of left ventricular function and morphology using an accelerated k-t sensitivity encoding method in cardiovascular magnetic resonance.

Authors:  Antonildes Nascimento Assuncao-Jr; Roberto Nery Dantas-Jr; Renata Margarida do Val; Priscilla Gianotto; Angela Dos Santos Marin; Mark Golden; Marco Antonio Gutierrez; Jose Rodrigues Parga; Cesar Higa Nomura
Journal:  Insights Imaging       Date:  2019-06-13

5.  Reliability of respiratory-triggered two-dimensional cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling for the assessment of biventricular volume and function in patients with repaired tetralogy of Fallot.

Authors:  Makoto Orii; Tsuyoshi Sugawara; Hidenobu Takagi; Satoshi Nakano; Hironobu Ueda; Yurie Takizawa; Jumpei Fujiwara; Shin Takahashi; Kotaro Oyama; Peng Lai; Martin A Janich; Atsushi Nozaki; Kunihiro Yoshioka
Journal:  Br J Radiol       Date:  2021-03-18       Impact factor: 3.039

6.  Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory.

Authors:  M Usman; B Ruijsink; M S Nazir; G Cruz; C Prieto
Journal:  Magn Reson Imaging       Date:  2016-12-26       Impact factor: 3.130

Review 7.  Reconstruction techniques for cardiac cine MRI.

Authors:  Rosa-María Menchón-Lara; Federico Simmross-Wattenberg; Pablo Casaseca-de-la-Higuera; Marcos Martín-Fernández; Carlos Alberola-López
Journal:  Insights Imaging       Date:  2019-09-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.