Literature DB >> 15173774

Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging.

Gary V Heller1, Timothy M Bateman, Lynne L Johnson, S James Cullom, James A Case, James R Galt, Ernest V Garcia, Keith Haddock, Kelly L Moutray, Carlos Poston, Eli H Botvinick, Matthews B Fish, William P Follansbee, Sean Hayes, Ami E Iskandrian, John J Mahmarian, William Vandecker.   

Abstract

BACKGROUND: Attenuation artifact remains a substantial limitation to confident interpretation of images and reduces laboratory efficiency by requiring comparison of stress and rest image sets. Attenuation-corrected stress-only imaging has the potential to ameliorate these limitations. METHODS AND
RESULTS: Ten experienced nuclear cardiologists independently interpreted 90 stress-only electrocardiography (ECG)-gated technetium 99m sestamibi images in a sequential fashion: myocardial perfusion imaging (MPI) alone, MPI plus ECG-gated data, and attenuation-corrected MPI with ECG-gated data. Images were interpreted for diagnostic certainty (normal, probably normal, equivocal, probably abnormal, abnormal, and perceived need for rest imaging). With stress MPI data alone, only 37% of studies were interpreted as definitely normal or abnormal, with a very high perceived need for rest imaging (77%). The addition of gated data did not alter the interpretations. However, attenuation-corrected data significantly increased the number of studies characterized as definitely normal or abnormal (84%, P <.005) and significantly reduced the perceived need for rest imaging (43%, P <.005). These results were confirmed by use of a nonsequential consensus interpretation of three readers.
CONCLUSION: Attenuation correction applied to studies with stress-only Tc-99m ECG-gated single photon emission computed tomography images significantly increases the ability to interpret studies as definitely normal or abnormal and reduces the need for rest imaging. These findings may improve laboratory efficiency and diagnostic accuracy.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15173774     DOI: 10.1016/j.nuclcard.2004.03.005

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  17 in total

1.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine.

Authors:  Robert C Hendel; James R Corbett; S James Cullom; E Gordon DePuey; Ernest V Garcia; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

2.  Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of 201Tl myocardial perfusion images.

Authors:  R Vidal; I Buvat; J Darcourt; O Migneco; P Desvignes; M Baudouy; F Bussière
Journal:  J Nucl Med       Date:  1999-08       Impact factor: 10.057

3.  Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images.

Authors:  Mathew Shotwell; Balkrishna M Singh; Charlotte Fortman; Brian D Bauman; Jennifer Lukes; Myron C Gerson
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

4.  Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease.

Authors:  D S Lee; Y So; G J Cheon; K M Kim; M M Lee; J K Chung; M C Lee
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

5.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

6.  Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer: impact on diagnostic accuracy.

Authors:  R Kluge; B Sattler; A Seese; W H Knapp
Journal:  Eur J Nucl Med       Date:  1997-09

7.  Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women.

Authors:  R Taillefer; E G DePuey; J E Udelson; G A Beller; Y Latour; F Reeves
Journal:  J Am Coll Cardiol       Date:  1997-01       Impact factor: 24.094

8.  Relation of gender to physician use of test results and to the prognostic value of stress technetium 99m sestamibi myocardial single-photon emission computed tomography scintigraphy.

Authors:  M I Travin; M D Duca; G M Kline; S D Herman; D D Demus; G V Heller
Journal:  Am Heart J       Date:  1997-07       Impact factor: 4.749

9.  Low event rate for stress-only perfusion imaging in patients evaluated for chest pain.

Authors:  Peter B Gibson; Diane Demus; Richard Noto; William Hudson; Lynne L Johnson
Journal:  J Am Coll Cardiol       Date:  2002-03-20       Impact factor: 24.094

10.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

View more
  61 in total

1.  Is it time for SPECT attenuation correction?

Authors:  Denny D Watson
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

2.  Patient-centered imaging.

Authors:  E Gordon Depuey; John J Mahmarian; Todd D Miller; Andrew J Einstein; Christopher L Hansen; Thomas A Holly; Edward J Miller; Donna M Polk; L Samuel Wann
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

3.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

4.  Quantitative Nuclear Cardiology: we are almost there!

Authors:  Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2012-03-31       Impact factor: 5.952

5.  Stress-only imaging: we can rest assured.

Authors:  Brian G Abbott
Journal:  J Nucl Cardiol       Date:  2010-06       Impact factor: 5.952

6.  Recommendations for reducing radiation exposure in myocardial perfusion imaging.

Authors:  Manuel D Cerqueira; Kevin C Allman; Edward P Ficaro; Christopher L Hansen; Kenneth J Nichols; Randall C Thompson; William A Van Decker; Marko Yakovlevitch
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 7.  Value of coronary CTA in patients with known or suspected CAD and non-diagnostic initial myocardial perfusion testing: current evidence and clinical considerations.

Authors:  Aiden Abidov; Gilbert L Raff
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

8.  Coronary CT angiography after stress testing: an efficient use of resources? Implications of the Advanced Cardiovascular Imaging Consortium (ACIC) results.

Authors:  Kavitha M Chinnaiyan; Gilbert L Raff; Karthik Ananthasubramaniam
Journal:  J Nucl Cardiol       Date:  2012-08       Impact factor: 5.952

9.  Very low-activity stress/high-activity rest, single-day myocardial perfusion SPECT with a conventional sodium iodide camera and wide beam reconstruction processing.

Authors:  E Gordon DePuey; Pashmina Ata; Rick Wray; Marvin Friedman
Journal:  J Nucl Cardiol       Date:  2012-07-10       Impact factor: 5.952

Review 10.  Imaging the myocardial ischemic cascade.

Authors:  Arthur E Stillman; Matthijs Oudkerk; David A Bluemke; Menko Jan de Boer; Jens Bremerich; Ernest V Garcia; Matthias Gutberlet; Pim van der Harst; W Gregory Hundley; Michael Jerosch-Herold; Dirkjan Kuijpers; Raymond Y Kwong; Eike Nagel; Stamatios Lerakis; John Oshinski; Jean-François Paul; Riemer H J A Slart; Vinod Thourani; Rozemarijn Vliegenthart; Bernd J Wintersperger
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-19       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.