Statistical validation of image segmentation quality based on a spatial overlap index.

Kelly H Zou1, Simon K Warfield, Aditya Bharatha, Clare M C Tempany, Michael R Kaus, Steven J Haker, William M Wells, Ferenc A Jolesz, Ron Kikinis.   

Abstract

RATIONALE AND
OBJECTIVES: To examine a statistical validation method based on the spatial overlap between two sets of segmentations of the same anatomy.
MATERIALS AND METHODS: The Dice similarity coefficient (DSC) was used as a statistical validation metric to evaluate the performance of both the reproducibility of manual segmentations and the spatial overlap accuracy of automated probabilistic fractional segmentation of MR images, illustrated on two clinical examples. Example 1: 10 consecutive cases of prostate brachytherapy patients underwent both preoperative 1.5T and intraoperative 0.5T MR imaging. For each case, 5 repeated manual segmentations of the prostate peripheral zone were performed separately on preoperative and on intraoperative images. Example 2: A semi-automated probabilistic fractional segmentation algorithm was applied to MR imaging of 9 cases with 3 types of brain tumors. DSC values were computed and logit-transformed values were compared in the mean with the analysis of variance (ANOVA).
RESULTS: Example 1: The mean DSCs of 0.883 (range, 0.876-0.893) with 1.5T preoperative MRI and 0.838 (range, 0.819-0.852) with 0.5T intraoperative MRI (P < .001) were within and at the margin of the range of good reproducibility, respectively. Example 2: Wide ranges of DSC were observed in brain tumor segmentations: Meningiomas (0.519-0.893), astrocytomas (0.487-0.972), and other mixed gliomas (0.490-0.899).
CONCLUSION: The DSC value is a simple and useful summary measure of spatial overlap, which can be applied to studies of reproducibility and accuracy in image segmentation. We observed generally satisfactory but variable validation results in two clinical applications. This metric may be adapted for similar validation tasks.

Entities:  

Mesh:

Year:  2004        PMID: 14974593      PMCID: PMC1415224          DOI: 10.1016/s1076-6332(03)00671-8

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  16 in total

1.  Partial volume tissue classification of multichannel magnetic resonance images-a mixel model.

Authors:  H S Choi; D R Haynor; Y Kim
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

2.  Original smooth receiver operating characteristic curve estimation from continuous data: statistical methods for analyzing the predictive value of spiral CT of ureteral stones.

Authors:  K H Zou; C M Tempany; J R Fielding; S G Silverman
Journal:  Acad Radiol       Date:  1998-10       Impact factor: 3.173

3.  Sample size requirements for the comparison of two or more coefficients of inter-observer agreement.

Authors:  A Donner
Journal:  Stat Med       Date:  1998-05-30       Impact factor: 2.373

4.  Graphical analysis of MR feature space for measurement of CSF, gray-matter, and white-matter volumes.

Authors:  D C Bonar; K A Schaper; J R Anderson; D A Rottenberg; S C Strother
Journal:  J Comput Assist Tomogr       Date:  1993 May-Jun       Impact factor: 1.826

5.  Dual-echo MRI segmentation using vector decomposition and probability techniques: a two-tissue model.

Authors:  Y H Kao; J A Sorenson; M M Bahn; S S Winkler
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

6.  Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging.

Authors:  A Bharatha; M Hirose; N Hata; S K Warfield; M Ferrant; K H Zou; E Suarez-Santana; J Ruiz-Alzola; A D'Amico; R A Cormack; R Kikinis; F A Jolesz; C M Tempany
Journal:  Med Phys       Date:  2001-12       Impact factor: 4.071

7.  Bayesian regression methodology for estimating a receiver operating characteristic curve with two radiologic applications: prostate biopsy and spiral CT of ureteral stones.

Authors:  A J Omalley; K H Zou; J R Fielding; C M Tempany
Journal:  Acad Radiol       Date:  2001-08       Impact factor: 3.173

8.  Validation of partial tissue segmentation of single-channel magnetic resonance images of the brain.

Authors:  T J Grabowski; R J Frank; N R Szumski; C K Brown; H Damasio
Journal:  Neuroimage       Date:  2000-12       Impact factor: 6.556

9.  Three validation metrics for automated probabilistic image segmentation of brain tumours.

Authors:  Kelly H Zou; William M Wells; Ron Kikinis; Simon K Warfield
Journal:  Stat Med       Date:  2004-04-30       Impact factor: 2.373

10.  Statistical validation based on parametric receiver operating characteristic analysis of continuous classification data.

Authors:  Kelly H Zou; Simon K Warfield; Julia R Fielding; Clare M C Tempany; M Wells William; Michael R Kaus; Ferenc A Jolesz; Ron Kikinis
Journal:  Acad Radiol       Date:  2003-12       Impact factor: 3.173

View more
  387 in total

1.  Quantitative analysis of brain pathology based on MRI and brain atlases--applications for cerebral palsy.

Authors:  Andreia V Faria; Alexander Hoon; Elaine Stashinko; Xin Li; Hangyi Jiang; Ameneh Mashayekh; Kazi Akhter; John Hsu; Kenichi Oishi; Jiangyang Zhang; Michael I Miller; Peter C M van Zijl; Susumu Mori
Journal:  Neuroimage       Date:  2010-11-05       Impact factor: 6.556

2.  Voxel classification and graph cuts for automated segmentation of pathological periprosthetic hip anatomy.

Authors:  Daniel F Malan; Charl P Botha; Edward R Valstar
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-01-21       Impact factor: 2.924

3.  Boundary estimation of fiber bundles derived from diffusion tensor images.

Authors:  Miriam Helen Anna Bauer; Sebastiano Barbieri; Jan Klein; Jan Egger; Daniela Kuhnt; Bernd Freisleben; Horst Karl Hahn; Christopher Nimsky
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-06-19       Impact factor: 2.924

Review 4.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

5.  Patient-specific non-linear finite element modelling for predicting soft organ deformation in real-time: application to non-rigid neuroimage registration.

Authors:  Adam Wittek; Grand Joldes; Mathieu Couton; Simon K Warfield; Karol Miller
Journal:  Prog Biophys Mol Biol       Date:  2010-09-22       Impact factor: 3.667

6.  Fast single photon avalanche photodiode-based time-resolved diffuse optical tomography scanner.

Authors:  Ying Mu; Mark Niedre
Journal:  Biomed Opt Express       Date:  2015-08-26       Impact factor: 3.732

7.  Generalized method for partial volume estimation and tissue segmentation in cerebral magnetic resonance images.

Authors:  April Khademi; Anastasios Venetsanopoulos; Alan R Moody
Journal:  J Med Imaging (Bellingham)       Date:  2014-04-23

Review 8.  Radiological images and machine learning: Trends, perspectives, and prospects.

Authors:  Zhenwei Zhang; Ervin Sejdić
Journal:  Comput Biol Med       Date:  2019-02-27       Impact factor: 4.589

9.  Automatic and Quantitative Measurement of Collagen Gel Contraction Using Model-Guided Segmentation.

Authors:  Hsin-Chen Chen; Tai-Hua Yang; Andrew R Thoreson; Chunfeng Zhao; Peter C Amadio; Yung-Nien Sun; Fong-Chin Su; Kai-Nan An
Journal:  Meas Sci Technol       Date:  2013-08       Impact factor: 2.046

10.  Morphometric analysis of peripheral myelinated nerve fibers through deep learning.

Authors:  Daniel Moiseev; Bo Hu; Jun Li
Journal:  J Peripher Nerv Syst       Date:  2018-12-11       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.