Literature DB >> 14729042

Cranioplasty using acrylic material: a new technical procedure.

Luigi Chiarini1, Sabina Figurelli, Giuseppe Pollastri, Elio Torcia, Francesca Ferrari, Massimo Albanese, Pier Francesco Nocini.   

Abstract

AIM: Today, cranioplasty is performed using different procedures. Numerous materials may be used to reconstruct the cranial vault including autologous bone and different types of synthetic resins. When plastic materials are used, the main requirement for an effective cranioplasty is the preoperative shaping of the implant to fit the bony defect precisely. In this paper, experience with a new method for cranioplasty using an acrylic cranial implant is presented.
MATERIAL AND METHODS: In this new technical procedure an acrylic implant, precisely shaped to the defect, is fabricated preoperatively using CT data. The study consists of 15 cases in whom cranioplasty was performed using this method. In all these, reconstruction was at least 3 months after the initial operation that lead to the cranial bony defect.
RESULTS: No major complications occurred and the final functional and aesthetic results were good in all cases. The acrylic implant manufacture does not require the use of complex computer interface software or high-tech equipment, but involves simple, cheap, repeatable processes.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14729042     DOI: 10.1016/j.jcms.2003.08.005

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  20 in total

1.  Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report.

Authors:  Ruy C C Abdo Filho; Thais M Oliveira; Natalino Lourenço Neto; Carla Gurgel; Ruy C C Abdo
Journal:  J Appl Oral Sci       Date:  2011-08       Impact factor: 2.698

2.  A technique for intraoperative creation of patient-specific titanium mesh implants.

Authors:  Ian Rp Sunderland; Glenn Edwards; James Mainprize; Oleh Antonyshyn
Journal:  Plast Surg (Oakv)       Date:  2015       Impact factor: 0.947

3.  [Evaluation of individual ceramic implants made of Bioverit with CAD/CAM technology to reconstruct multidimensional craniofacial defects of the human skull].

Authors:  H Siebert; P Schleier; J Beinemann; W Fried; W Zenk; D Schumann
Journal:  Mund Kiefer Gesichtschir       Date:  2006-05

4.  Evaluation of soft tissue coverage over porous polymethylmethacrylate space maintainers within nonhealing alveolar bone defects.

Authors:  James D Kretlow; Meng Shi; Simon Young; Patrick P Spicer; Nagi Demian; John A Jansen; Mark E Wong; F Kurtis Kasper; Antonios G Mikos
Journal:  Tissue Eng Part C Methods       Date:  2010-06-04       Impact factor: 3.056

5.  A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury.

Authors:  JingLe Jiang; Amar R Marathe; Jennifer C Keene; Dawn M Taylor
Journal:  J Neurosci Methods       Date:  2016-12-12       Impact factor: 2.390

6.  In situ formation of porous space maintainers in a composite tissue defect.

Authors:  Patrick P Spicer; James D Kretlow; Allan M Henslee; Meng Shi; Simon Young; Nagi Demian; John A Jansen; Mark E Wong; Antonios G Mikos; F Kurtis Kasper
Journal:  J Biomed Mater Res A       Date:  2012-01-12       Impact factor: 4.396

Review 7.  Calvarial Reconstruction.

Authors:  Arvind Badhey; Sameep Kadakia; Moustafa Mourad; Jared Inman; Yadranko Ducic
Journal:  Semin Plast Surg       Date:  2017-10-25       Impact factor: 2.314

8.  Effect of microencapsulated phase change materials on the thermo-mechanical properties of poly(methyl-methacrylate) based biomaterials.

Authors:  Roberto De Santis; Veronica Ambrogi; Cosimo Carfagna; Luigi Ambrosio; Luigi Nicolais
Journal:  J Mater Sci Mater Med       Date:  2006-12       Impact factor: 3.896

Review 9.  Building bridges: leveraging interdisciplinary collaborations in the development of biomaterials to meet clinical needs.

Authors:  Eliza L S Fong; Brendan M Watson; F Kurtis Kasper; Antonios G Mikos
Journal:  Adv Mater       Date:  2012-07-23       Impact factor: 30.849

10.  Cranioplasty with custom made alloplastic prosthetic implant: A case report.

Authors:  Lokendra Gupta; In Aparna; Dhanasekar Balakrishnan; Lingeshwar Deenadayalan; Puneeth Hegde; Priyanka Agarwal
Journal:  World J Clin Cases       Date:  2014-09-16       Impact factor: 1.337

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.