Improved electrode for electroretinography.

W W Dawson, G L Trick, C A Litzkow.   

Abstract

Corneal electrodes useful for clinical electroretinography require topical anesthesia, interfere with vision, can abrade, and are not well accepted by most children and many adults. A low mass conductive thread, corneal (DTL) electrode is described and comparatively tested against the Burian-Allen electrode. The DTL electrode was found to have few of the limitations of the hard contact lens electrode. Furthermore, the DTL electrode signal quality was comparable to that of the Burian-Allen electrode and provided less between-patient variability.

Entities:  

Mesh:

Year:  1979        PMID: 478786

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  113 in total

1.  Background light adaptation of the retinal neuronal adaptive system. I. Effect of background light intensity.

Authors:  L Wang; M el Azazi; A Eklund; W Lillemor
Journal:  Doc Ophthalmol       Date:  2001-07       Impact factor: 2.379

2.  Inner-retinal contributions to the photopic sinusoidal flicker electroretinogram of macaques. Macaque photopic sinusoidal flicker ERG.

Authors:  Suresh Viswanathan; Laura J Frishman; John G Robson
Journal:  Doc Ophthalmol       Date:  2002-09       Impact factor: 2.379

3.  Safety and efficacy evaluation of a new ERG electrode (the LVP electrode) part II. Flash ERG pilot study.

Authors:  L S Mohan Ram; Subhadra Jalali; Shaikh Faheemuddin; Taraprasad Das; Rishita Nutheti
Journal:  Doc Ophthalmol       Date:  2003-09       Impact factor: 2.379

4.  Safety and efficacy evaluation of a new electrode (the LVP electrode) part I. Pattern ERG pilot study.

Authors:  L S Mohan Ram; Subhadra Jalali; P S Roopa Reddy; Vallam Srinivasa Rao; Traraprasad Das; Rishita Nutheti
Journal:  Doc Ophthalmol       Date:  2003-09       Impact factor: 2.379

5.  The influence of ambient room lighting on the pattern electroretinogram (PERG).

Authors:  Michael Bach; Margret Schumacher
Journal:  Doc Ophthalmol       Date:  2002-11       Impact factor: 2.379

6.  New noncorneal HK-loop electrode for clinical electroretinography.

Authors:  M Hawlina; B Konec
Journal:  Doc Ophthalmol       Date:  1992       Impact factor: 2.379

7.  Different effect of dioptric defocus vs. light scatter on the pattern electroretinogram (PERG).

Authors:  Michael Bach; Marcel Mathieu
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

8.  The scotopic threshold response of the dark-adapted electroretinogram of the mouse.

Authors:  Shannon M Saszik; John G Robson; Laura J Frishman
Journal:  J Physiol       Date:  2002-09-15       Impact factor: 5.182

9.  Improved contact lens electrode for corneal ERG recordings in mice.

Authors:  Botir T Sagdullaev; Paul J DeMarco; Maureen A McCall
Journal:  Doc Ophthalmol       Date:  2004-05       Impact factor: 2.379

Review 10.  Electrical stimulation of cranial nerves in cognition and disease.

Authors:  Devin Adair; Dennis Truong; Zeinab Esmaeilpour; Nigel Gebodh; Helen Borges; Libby Ho; J Douglas Bremner; Bashar W Badran; Vitaly Napadow; Vincent P Clark; Marom Bikson
Journal:  Brain Stimul       Date:  2020-02-23       Impact factor: 8.955

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.