Literature DB >> 28567618

Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography.

Barbara Cvenkel1, Maja Sustar2, Darko Perovšek2.   

Abstract

PURPOSE: To evaluate discrimination ability of pattern electroretinography (PERG) and photopic negative response (PhNR) between early glaucoma and healthy controls, and their relationship with structural measurements using spectral-domain optical coherence tomography (SD-OCT).
METHODS: Cross-sectional study with 34 patients with ocular hypertension (n = 7), suspect glaucoma (n = 17), and early glaucoma (n = 10), plus 24 age-matched controls. The following parameters were analyzed: P50 and N95 amplitude of the PERG, PhNR amplitude and PhNR/b-wave ratio, peripapillary retinal and macular nerve fiber layer (NFL) thicknesses, and ganglion cell complex (GCC) thickness. Data from only one eye per individual were included in the statistical analysis. Descriptive statistics, ANOVA, receiver operating characteristics (ROC) curves, and correlation tests were used for analysis of the variables.
RESULTS: PERG N95 and PhNR amplitudes were significantly reduced in suspect and early glaucoma eyes versus controls. Significant differences across ocular hypertensive, suspect, and early glaucoma eyes were found for macular NFL and GCC thickness, but not for any of the ERG parameters. The mean PhNR amplitude did not differ across these groups and was already reduced on average by 46% in ocular hypertensive and early glaucoma eyes and by 52% in suspect glaucoma eyes. The P50 and N95 amplitudes showed similar reduction in suspect and early glaucoma eyes on average by 15 and 26%, respectively. Of the ERG parameters, PhNR amplitude distinguished best between glaucoma and control groups, with an area under ROC curve of 0.90 for suspect glaucoma, and 0.86 for early glaucoma. PhNR/b-wave ratio showed strongest association in suspect glaucoma eyes with peripapillary retinal (r, 0.61) and macular NFL (r, 0.76) thicknesses. In eyes with early glaucoma, peripapillary retinal NFL thickness correlated best with PhNR amplitude (r, 0.71) and PERG P50 amplitude (r, 0.67).
CONCLUSIONS: In eyes with suspect glaucoma, important decrease in PhNR amplitude is associated with small changes in peripapillary retinal and macular NFL thicknesses. These findings suggest that PhNR may be a useful and sensitive test in eyes with diagnostic dilemma, although further follow-up of such eyes is required for definitive confirmation.

Entities:  

Keywords:  Glaucoma; Nerve fiber layer thickness; Optical coherence tomography; Pattern electroretinogram; Photopic electroretinogram; Photopic negative response

Mesh:

Year:  2017        PMID: 28567618     DOI: 10.1007/s10633-017-9595-9

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  36 in total

1.  Reversal of retinal ganglion cell dysfunction after surgical reduction of intraocular pressure.

Authors:  Mitra Sehi; Dilraj S Grewal; Margot L Goodkin; David S Greenfield
Journal:  Ophthalmology       Date:  2010-10-08       Impact factor: 12.079

2.  The s-cone PHNR and pattern ERG in primary open angle glaucoma.

Authors:  N Drasdo; Y H Aldebasi; Z Chiti; K E Mortlock; J E Morgan; R V North
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-05       Impact factor: 4.799

3.  The photopic negative response of the flash electroretinogram in primary open angle glaucoma.

Authors:  S Viswanathan; L J Frishman; J G Robson; J W Walters
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-02       Impact factor: 4.799

4.  Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons.

Authors:  L A Kerrigan-Baumrind; H A Quigley; M E Pease; D F Kerrigan; R S Mitchell
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-03       Impact factor: 4.799

5.  Photopic negative response of the human ERG: losses associated with glaucomatous damage.

Authors:  A Colotto; B Falsini; T Salgarello; G Iarossi; M E Galan; L Scullica
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-07       Impact factor: 4.799

6.  Inter-subject, inter-ocular and inter-session repeatability of the photopic negative response of the electroretinogram recorded using DTL and skin electrodes.

Authors:  Katharine E Mortlock; Alison M Binns; Yousef H Aldebasi; Rachel V North
Journal:  Doc Ophthalmol       Date:  2010-07-06       Impact factor: 2.379

7.  Intraocular pressure lowering is associated with an increase in the photopic negative response (PhNR) amplitude in glaucoma and ocular hypertensive eyes.

Authors:  Nuwan Niyadurupola; Chi D Luu; Dan Q Nguyen; Kristen Geddes; Gary X V Tan; Celestine C W Wong; Tu Tran; Michael A Coote; Jonathan G Crowston
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-03-15       Impact factor: 4.799

8.  Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography.

Authors:  Andreas U Bayer; Klaus-Peter Maag; Carl Erb
Journal:  Ophthalmology       Date:  2002-07       Impact factor: 12.079

9.  ISCEV standard for clinical pattern electroretinography--2007 update.

Authors:  Graham E Holder; Mitchell G Brigell; Marko Hawlina; Thomas Meigen; Michael Bach
Journal:  Doc Ophthalmol       Date:  2007-04-14       Impact factor: 2.379

Review 10.  Practical recommendations for measuring rates of visual field change in glaucoma.

Authors:  B C Chauhan; D F Garway-Heath; F J Goñi; L Rossetti; B Bengtsson; A C Viswanathan; A Heijl
Journal:  Br J Ophthalmol       Date:  2008-01-22       Impact factor: 4.638

View more
  22 in total

1.  Photopic negative response using a handheld mini-ganzfeld stimulator in healthy adults: normative values, intra- and inter-session variability.

Authors:  Adriana Berezovsky; Rustum Karanjia; Arthur Gustavo Fernandes; Gabriel Izan Santos Botelho; Tatiane Luana Novele Bueno; Nívea Nunes Ferraz; Paula Yuri Sacai; Stuart Glenn Coupland; Alfredo Arrigo Sadun; Solange Rios Salomão
Journal:  Doc Ophthalmol       Date:  2020-07-17       Impact factor: 2.379

2.  The photopic negative response of the Light-adapted 3.0 ERG in clinical settings.

Authors:  Gonzalo Ortiz; David Drucker; Connor Hyde; Joseph Staffetti; Jan Kremers; Radouil Tzekov
Journal:  Doc Ophthalmol       Date:  2019-10-01       Impact factor: 2.379

3.  Asymmetric Functional Impairment of ON and OFF Retinal Pathways in Glaucoma.

Authors:  Alan W Kong; Marcus L Turner; Hoover Chan; Robert L Stamper; Benjamin F Arnold; Luca Della Santina; Yvonne Ou
Journal:  Ophthalmol Sci       Date:  2021-05-10

4.  Measurements of OCT Angiography Complement OCT for Diagnosing Early Primary Open-Angle Glaucoma.

Authors:  Alireza Kamalipour; Sasan Moghimi; Cris Martin Jacoba; Adeleh Yarmohammadi; Kaileen Yeh; James A Proudfoot; Huiyuan Hou; Takashi Nishida; Ryan Caezar David; Jasmin Rezapour; Nevin El-Nimri; Robert N Weinreb
Journal:  Ophthalmol Glaucoma       Date:  2021-10-09

5.  Visual function in guinea pigs: behavior and electrophysiology.

Authors:  Ashutosh Jnawali; Sudan Puri; Laura J Frishman; Lisa A Ostrin
Journal:  Clin Exp Optom       Date:  2021-02-27       Impact factor: 2.742

6.  Optimizing a Portable ERG Device for Glaucoma Clinic: The Effect of Interstimulus Frequency on the Photopic Negative Response.

Authors:  Flora Hui; Jessica Tang; Xavier Hadoux; Michael Coote; Jonathan G Crowston
Journal:  Transl Vis Sci Technol       Date:  2018-12-21       Impact factor: 3.283

7.  A Comparison of the RETeval Sensor Strip and DTL Electrode for Recording the Photopic Negative Response.

Authors:  Jessica Tang; Flora Hui; Xavier Hadoux; Marc Sarossy; Peter van Wijngaarden; Michael Coote; Jonathan G Crowston
Journal:  Transl Vis Sci Technol       Date:  2018-12-21       Impact factor: 3.283

Review 8.  Discovery and clinical translation of novel glaucoma biomarkers.

Authors:  Gala Beykin; Anthony M Norcia; Vivek J Srinivasan; Alfredo Dubra; Jeffrey L Goldberg
Journal:  Prog Retin Eye Res       Date:  2020-07-10       Impact factor: 21.198

9.  The role of pattern electroretinograms and optical coherence tomography angiography in the diagnosis of normal-tension glaucoma.

Authors:  Sang Yeop Lee; Nak-Hoon Son; Hyoung Won Bae; Gong Je Seong; Chan Yun Kim
Journal:  Sci Rep       Date:  2021-06-10       Impact factor: 4.379

10.  Baseline Detrending for the Photopic Negative Response.

Authors:  Jessica Tang; Flora Hui; Michael Coote; Jonathan G Crowston; Xavier Hadoux
Journal:  Transl Vis Sci Technol       Date:  2018-09-21       Impact factor: 3.283

View more