Literature DB >> 14674806

Correlation between quantitative fit factors and workplace protection factors measured in actual workplace environments at a steel foundry.

Ziqing Zhuang1, Christopher C Coffey, Paul A Jensen, Donald L Campbell, Robert B Lawrence, Warren R Myers.   

Abstract

Past studies have found little or no correlation between workplace protection factors (WPFs) and quantitative fit factors (FFs). This study investigated the effect of good- and poor-fitting half-facepiece, air-purifying respirators on protection in actual workplace environments at a steel foundry and the correlation between WPFs and FFs. Fifteen burners and welders, who wore respirators voluntarily, and chippers participated in this study. Each subject was fit-tested with two respirator models each with three sizes, for a total of six fit-tests. Models and sizes were assigned this way to provide a wide range of FFs among study participants. Each worker donned the respirator twice per day (at the beginning of the shift and following the lunch break) for 2 days. Quantitative FFs were first obtained for each donning using the PortaCount Plus trade mark in a separate room. Without redonning the respirators, workers performed normal work for 1 to 2 hours, and WPFs were measured by collecting ambient and in-facepiece samples simultaneously. A second fit-test was conducted without disturbing the respirator. FFs were obtained by averaging the results from the first and second fit-tests. The resulting FFs had a geometric mean (GM) of 400 (range=10-6010) and a geometric standard deviation (GSD) of 6.1. Of the 55 valid donnings, 43 were good fitting (FFs> or =100) and 12 were poor fitting (FFs<100). The WPFs had a GM of 920 (range=13-230,000) and a GSD of 17.8. The WPFs were found to be significantly correlated with the FFs (R(2)=.55 and p-value=.0001). Therefore, FF was shown to be a meaningful indicator of respirator performance in actual workplace environments.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14674806     DOI: 10.1202/475.1

Source DB:  PubMed          Journal:  AIHA J (Fairfax, Va)        ISSN: 1542-8117


  14 in total

1.  Assessing the efficacy of tabs on filtering facepiece respirator straps to increase proper doffing techniques while reducing contact transmission of pathogens.

Authors:  Amanda L Strauch; Tyler M Brady; George Niezgoda; Claudia M Almaguer; Ronald E Shaffer; Edward M Fisher
Journal:  J Occup Environ Hyg       Date:  2016-10-02       Impact factor: 2.155

2.  Correlation of respirator fit measured on human subjects and a static advanced headform.

Authors:  Michael S Bergman; Xinjian He; Michael E Joseph; Ziqing Zhuang; Brian K Heimbuch; Ronald E Shaffer; Melanie Choe; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

3.  Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators.

Authors:  Ziqing Zhuang; Michael Bergman; Zhipeng Lei; George Niezgoda; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2017-06       Impact factor: 2.155

4.  A comparison of total inward leakage measured using sodium chloride (NaCl) and corn oil aerosol methods for air-purifying respirators.

Authors:  Samy Rengasamy; Ziqing Zhuang; George Niezgoda; Gary Walbert; Robert Lawrence; Brenda Boutin; Judith Hudnall; William P Monaghan; Michael Bergman; Colleen Miller; James Harris; Christopher Coffey
Journal:  J Occup Environ Hyg       Date:  2018-08       Impact factor: 2.155

5.  Protection factor for N95 filtering facepiece respirators exposed to laboratory aerosols containing different concentrations of nanoparticles.

Authors:  Samy Rengasamy; Gary Walbert; William Newcomb; Christopher Coffey; James Terrence Wassell; Jonathan Szalajda
Journal:  Ann Occup Hyg       Date:  2014-11-25

6.  Criteria for the collection of useful respirator performance data in the workplace.

Authors:  Larry Janssen; Ziqing Zhuang; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

7.  Evaluation of dermal absorption and protective effectiveness of respirators for xylene in spray painters.

Authors:  Fu-Kuei Chang; Mei-Lien Chen; Shu-Fang Cheng; Tung-Sheng Shih; I-Fang Mao
Journal:  Int Arch Occup Environ Health       Date:  2007-05-10       Impact factor: 3.015

8.  Development of an advanced respirator fit-test headform.

Authors:  Michael S Bergman; Ziqing Zhuang; David Hanson; Brian K Heimbuch; Michael J McDonald; Andrew J Palmiero; Ronald E Shaffer; Delbert Harnish; Michael Husband; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

9.  Stockpiled N95 Filtering Facepiece Respirator Polyisoprene Strap Performance.

Authors:  Dana R Rottach; Zhipeng Lei
Journal:  J Int Soc Respir Prot       Date:  2017

10.  Using CO(2) to determine inhaled contaminant volumes and blower effectiveness in several types of respirators.

Authors:  Arthur T Johnson; Frank C Koh; William H Scott; Timothy E Rehak
Journal:  J Environ Public Health       Date:  2011-07-18