Literature DB >> 29781773

A comparison of total inward leakage measured using sodium chloride (NaCl) and corn oil aerosol methods for air-purifying respirators.

Samy Rengasamy1, Ziqing Zhuang1, George Niezgoda1, Gary Walbert1, Robert Lawrence1, Brenda Boutin1, Judith Hudnall1, William P Monaghan1, Michael Bergman1, Colleen Miller1, James Harris1, Christopher Coffey1.   

Abstract

The International Organization for Standardization (ISO) standard 16900-1:2014 specifies the use of sodium chloride (NaCl) and corn oil aerosols, and sulfur hexafluoride gas for measuring total inward leakage (TIL). However, a comparison of TIL between different agents is lacking. The objective of this study was to measure and compare TIL for respirators using corn oil and NaCl aerosols. TIL was measured with 10 subjects donning two models of filtering facepiece respirators (FFRs) including FFP1, N95, P100, and elastomeric half-mask respirators (ERs) in NaCl and corn oil aerosol test chambers, using continuous sampling methods. After fit testing with a PortaCount (TSI, Inc., St. Paul, MN) using the Occupational Safety and Health Administration (OSHA) protocol, five subjects were tested in the NaCl chamber first and then in the corn oil chamber, while other subjects tested in the reverse order. TIL was measured as a ratio of mass-based aerosol concentrations in-mask to the test chamber, while the subjects performed ISO 16900-1-defined exercises. The concentration of NaCl aerosol was measured using two flame photometers, and corn oil aerosol was measured with one light scattering photometer. The same instruments were used to measure filter penetration in both chambers using a Plexiglas setup. The size distribution of aerosols was determined using a scanning mobility particle sizer and charge was measured with an electrometer. Filter efficiency was measured using an 8130 Automated Filter Tester (TSI). Results showed the geometric mean TIL for corn oil aerosol for one model each of all respirator categories, except P100, were significantly (p < 0.05) greater than for NaCl aerosol. Filter penetration in the two test chambers showed a trend similar to TIL. The count median diameter was ∼82 nm for NaCl and ∼200 nm for corn oil aerosols. The net positive charge for NaCl aerosol was relatively larger. Both fit factor and filter efficiency influence TIL measurement. Overall, TIL determination with aerosols of different size distributions and charges using different methodologies may produce dissimilar results.

Entities:  

Keywords:  Corn oil aerosol; FFP1; N95; NaCl aerosol; P100 and elastomeric half-facepiece respirators; faceseal leakage; filter efficiency; filter penetration; total inward leakage

Mesh:

Substances:

Year:  2018        PMID: 29781773      PMCID: PMC6198249          DOI: 10.1080/15459624.2018.1479064

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  19 in total

1.  Correlation between quantitative fit factors and workplace protection factors measured in actual workplace environments at a steel foundry.

Authors:  Ziqing Zhuang; Christopher C Coffey; Paul A Jensen; Donald L Campbell; Robert B Lawrence; Warren R Myers
Journal:  AIHA J (Fairfax, Va)       Date:  2003 Nov-Dec

2.  Nanoparticle penetration through filter media and leakage through face seal interface of N95 filtering facepiece respirators.

Authors:  Samy Rengasamy; Benjamin C Eimer
Journal:  Ann Occup Hyg       Date:  2012-01-31

Review 3.  Aerosol deposition in health and disease.

Authors:  Chantal Darquenne
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2012-06       Impact factor: 2.849

4.  Simulated workplace protection factors for half-facepiece respiratory protective devices.

Authors:  Matthew G Duling; Robert B Lawrence; James E Slaven; Christopher C Coffey
Journal:  J Occup Environ Hyg       Date:  2007-06       Impact factor: 2.155

5.  Total inward leakage measurement of particulates for N95 filtering facepiece respirators--a comparison study.

Authors:  Samy Rengasamy; Gary F Walbert; William E Newcomb; Kimberly Faulkner; Mathi M Rengasamy; Jeremy J Brannen; Jonathan V Szalajda
Journal:  Ann Occup Hyg       Date:  2013-10-09

6.  Protection factor for N95 filtering facepiece respirators exposed to laboratory aerosols containing different concentrations of nanoparticles.

Authors:  Samy Rengasamy; Gary Walbert; William Newcomb; Christopher Coffey; James Terrence Wassell; Jonathan Szalajda
Journal:  Ann Occup Hyg       Date:  2014-11-25

7.  Evaluation of particulate filtering respirators using inward leakage (IL) or total inward leakage (TIL) testing--Korean experience.

Authors:  Don-Hee Han; Jinheon Lee
Journal:  Ann Occup Hyg       Date:  2005-08-26

8.  Performance of N95 FFRs Against Combustion and NaCl Aerosols in Dry and Moderately Humid Air: Manikin-based Study.

Authors:  Shuang Gao; Jinyong Kim; Michael Yermakov; Yousef Elmashae; Xinjian He; Tiina Reponen; Ziqing Zhuang; Samy Rengasamy; Sergey A Grinshpun
Journal:  Ann Occup Hyg       Date:  2016-04-19

9.  A quantitative assessment of the total inward leakage of NaCl aerosol representing submicron-size bioaerosol through N95 filtering facepiece respirators and surgical masks.

Authors:  Samy Rengasamy; Benjamin C Eimer; Jonathan Szalajda
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

10.  Respiratory performance offered by N95 respirators and surgical masks: human subject evaluation with NaCl aerosol representing bacterial and viral particle size range.

Authors:  Shu-An Lee; Sergey A Grinshpun; Tiina Reponen
Journal:  Ann Occup Hyg       Date:  2008-03-07
View more
  10 in total

1.  Qualitative fitting characteristics of filtering face-piece respirators on Iranian people.

Authors:  Anahita Fakherpour; Mehdi Jahangiri; Mozhgan Seif
Journal:  J Environ Health Sci Eng       Date:  2020-05-26

Review 2.  A comprehensive review on facemask manufacturing, testing, and its environmental impacts.

Authors:  Junaid Khan; Netnapa E; M Mariatti; V Vilay; M Todo
Journal:  J Ind Text       Date:  2022-10-06       Impact factor: 2.926

3.  Can respirator face masks in a developing country reduce exposure to ambient particulate matter?

Authors:  Sasan Faridi; Ramin Nabizadeh Nodehi; Saeed Sadeghian; Masih Tajdini; Mohammad Hoseini; Masud Yunesian; Shahrokh Nazmara; Mohammad Sadegh Hassanvand; Kazem Naddafi
Journal:  J Expo Sci Environ Epidemiol       Date:  2020-04-21       Impact factor: 5.563

4.  Meltblown fabric vs nanofiber membrane, which is better for fabricating personal protective equipments.

Authors:  Junwei Wu; Hongjia Zhou; Jingyi Zhou; Xiao Zhu; Bowen Zhang; Shasha Feng; Zhaoxiang Zhong; Lingxue Kong; Weihong Xing
Journal:  Chin J Chem Eng       Date:  2020-11-23       Impact factor: 3.171

Review 5.  Essentials in saline pharmacology for nasal or respiratory hygiene in times of COVID-19.

Authors:  Suzy Huijghebaert; Levi Hoste; Guido Vanham
Journal:  Eur J Clin Pharmacol       Date:  2021-03-27       Impact factor: 2.953

6.  Screening of core filter layer for the development of respiratory mask to combat COVID-19.

Authors:  Lokesh K Pandey; Virendra V Singh; Pushpendra K Sharma; Damayanti Meher; Utpal Biswas; Manisha Sathe; Kumaran Ganesan; Vikas B Thakare; Kavita Agarwal
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.379

Review 7.  Masks for COVID-19.

Authors:  Wei Deng; Yajun Sun; Xiaoxue Yao; Karpagam Subramanian; Chen Ling; Hongbo Wang; Shauhrat S Chopra; Ben Bin Xu; Jie-Xin Wang; Jian-Feng Chen; Dan Wang; Honeyfer Amancio; Stevin Pramana; Ruquan Ye; Steven Wang
Journal:  Adv Sci (Weinh)       Date:  2021-11-26       Impact factor: 16.806

Review 8.  Efficacy and safety of decontamination for N95 respirator reuse: a systematic literature search and narrative synthesis.

Authors:  Benjamin E Steinberg; Kazuyoshi Aoyama; Mark McVey; David Levin; Asad Siddiqui; Farrukh Munshey; Neil M Goldenberg; David Faraoni; Jason T Maynes
Journal:  Can J Anaesth       Date:  2020-07-27       Impact factor: 6.713

Review 9.  Universal masking during COVID-19 pandemic: Can textile engineering help public health? Narrative review of the evidence.

Authors:  Sanjay Beesoon; Nemeshwaree Behary; Anne Perwuelz
Journal:  Prev Med       Date:  2020-08-11       Impact factor: 4.018

Review 10.  Rapid Review of SARS-CoV-1 and SARS-CoV-2 Viability, Susceptibility to Treatment, and the Disinfection and Reuse of PPE, Particularly Filtering Facepiece Respirators.

Authors:  José G B Derraik; William A Anderson; Elizabeth A Connelly; Yvonne C Anderson
Journal:  Int J Environ Res Public Health       Date:  2020-08-22       Impact factor: 3.390

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.