Literature DB >> 24369934

Development of an advanced respirator fit-test headform.

Michael S Bergman1, Ziqing Zhuang, David Hanson, Brian K Heimbuch, Michael J McDonald, Andrew J Palmiero, Ronald E Shaffer, Delbert Harnish, Michael Husband, Joseph D Wander.   

Abstract

Improved respirator test headforms are needed to measure the fit of N95 filtering facepiece respirators (FFRs) for protection studies against viable airborne particles. A Static (i.e., non-moving, non-speaking) Advanced Headform (StAH) was developed for evaluating the fit of N95 FFRs. The StAH was developed based on the anthropometric dimensions of a digital headform reported by the National Institute for Occupational Safety and Health (NIOSH) and has a silicone polymer skin with defined local tissue thicknesses. Quantitative fit factor evaluations were performed on seven N95 FFR models of various sizes and designs. Donnings were performed with and without a pre-test leak checking method. For each method, four replicate FFR samples of each of the seven models were tested with two donnings per replicate, resulting in a total of 56 tests per donning method. Each fit factor evaluation was comprised of three 86-sec exercises: "Normal Breathing" (NB, 11.2 liters per min (lpm)), "Deep Breathing" (DB, 20.4 lpm), then NB again. A fit factor for each exercise and an overall test fit factor were obtained. Analysis of variance methods were used to identify statistical differences among fit factors (analyzed as logarithms) for different FFR models, exercises, and testing methods. For each FFR model and for each testing method, the NB and DB fit factor data were not significantly different (P > 0.05). Significant differences were seen in the overall exercise fit factor data for the two donning methods among all FFR models (pooled data) and in the overall exercise fit factor data for the two testing methods within certain models. Utilization of the leak checking method improved the rate of obtaining overall exercise fit factors ≥100. The FFR models, which are expected to achieve overall fit factors ≥ 100 on human subjects, achieved overall exercise fit factors ≥ 100 on the StAH. Further research is needed to evaluate the correlation of FFRs fitted on the StAH to FFRs fitted on people. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a file providing detailed information on the advanced head form design and fabrication process.].

Entities:  

Mesh:

Year:  2014        PMID: 24369934      PMCID: PMC4470376          DOI: 10.1080/15459624.2013.816434

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  26 in total

1.  Respiratory protection as a function of respirator fitting characteristics and fit-test accuracy.

Authors:  D L Campbell; C C Coffey; S W Lenhart
Journal:  AIHAJ       Date:  2001 Jan-Feb

2.  Correlation between quantitative fit factors and workplace protection factors measured in actual workplace environments at a steel foundry.

Authors:  Ziqing Zhuang; Christopher C Coffey; Paul A Jensen; Donald L Campbell; Robert B Lawrence; Warren R Myers
Journal:  AIHA J (Fairfax, Va)       Date:  2003 Nov-Dec

3.  Comparison of five methods for fit-testing N95 filtering-facepiece respirators.

Authors:  Christopher C Coffey; Robert B Lawrence; Ziqing Zhuang; Donald L Campbell; Paul A Jensen; Warren R Myers
Journal:  Appl Occup Environ Hyg       Date:  2002-10

4.  Digital 3-D headforms with facial features representative of the current US workforce.

Authors:  Ziqing Zhuang; Stacey Benson; Dennis Viscusi
Journal:  Ergonomics       Date:  2010-05       Impact factor: 2.778

5.  Workplace protection factors for an N95 filtering facepiece respirator.

Authors:  Larry L Janssen; Thomas J Nelson; Karen T Cuta
Journal:  J Occup Environ Hyg       Date:  2007-09       Impact factor: 2.155

6.  New respirator fit test panels representing the current U.S. civilian work force.

Authors:  Ziqing Zhuang; Bruce Bradtmiller; Ronald E Shaffer
Journal:  J Occup Environ Hyg       Date:  2007-09       Impact factor: 2.155

7.  Novel influenza A (H1N1) virus infections among health-care personnel - United States, April-May 2009.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2009-06-19       Impact factor: 17.586

8.  Respiratory protection against Mycobacterium tuberculosis: quantitative fit test outcomes for five type N95 filtering-facepiece respirators.

Authors:  Kiyoung Lee; Andrea Slavcev; Mark Nicas
Journal:  J Occup Environ Hyg       Date:  2004-01       Impact factor: 2.155

9.  Performance of an N95 filtering facepiece particulate respirator and a surgical mask during human breathing: two pathways for particle penetration.

Authors:  Sergey A Grinshpun; Hiroki Haruta; Robert M Eninger; Tiina Reponen; Roy T McKay; Shu-An Lee
Journal:  J Occup Environ Hyg       Date:  2009-10       Impact factor: 2.155

10.  Implementing fit testing for N95 filtering facepiece respirators: practical information from a large cohort of hospital workers.

Authors:  Elizabeth McMahon; Koji Wada; André Dufresne
Journal:  Am J Infect Control       Date:  2008-05       Impact factor: 2.918

View more
  15 in total

1.  Correlation of respirator fit measured on human subjects and a static advanced headform.

Authors:  Michael S Bergman; Xinjian He; Michael E Joseph; Ziqing Zhuang; Brian K Heimbuch; Ronald E Shaffer; Melanie Choe; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

2.  Efficacy of face masks, neck gaiters and face shields for reducing the expulsion of simulated cough-generated aerosols.

Authors:  William G Lindsley; Francoise M Blachere; Brandon F Law; Donald H Beezhold; John D Noti
Journal:  Aerosol Sci Technol       Date:  2021-01-07       Impact factor: 4.809

3.  A comparison of performance metrics for cloth masks as source control devices for simulated cough and exhalation aerosols.

Authors:  William G Lindsley; Francoise M Blachere; Donald H Beezhold; Brandon F Law; Raymond C Derk; Justin M Hettick; Karen Woodfork; William T Goldsmith; James R Harris; Matthew G Duling; Brenda Boutin; Timothy Nurkiewicz; Theresa Boots; Jayme Coyle; John D Noti
Journal:  Aerosol Sci Technol       Date:  2021-06-14       Impact factor: 4.809

4.  Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

Authors:  Xinjian He; Sergey A Grinshpun; Tiina Reponen; Roy McKay; Michael S Bergman; Ziqing Zhuang
Journal:  Ann Occup Hyg       Date:  2013-10-08

5.  Development of a Manikin-Based Performance Evaluation Method for Loose-Fitting Powered Air-Purifying Respirators.

Authors:  Mike Bergman; Rohan Basu; Zhipeng Lei; George Niezgoda; Ziqing Zhuang
Journal:  J Int Soc Respir Prot       Date:  2017

6.  A Review of Decontamination Methods for Filtering Facepiece Respirators.

Authors:  Mike Bergman; Edward M Fisher; Brian K Heimbuch
Journal:  J Int Soc Respir Prot       Date:  2020-10-09

7.  Evaluation of Rigidity of Surgical N95 Respirators Using a Manikin-System: A Pilot Study.

Authors:  Samy Rengasamy; George Niezgoda
Journal:  J Int Soc Respir Prot       Date:  2019

Review 8.  Unlocking the surge in demand for personal and protective equipment (PPE) and improvised face coverings arising from coronavirus disease (COVID-19) pandemic - Implications for efficacy, re-use and sustainable waste management.

Authors:  Neil J Rowan; John G Laffey
Journal:  Sci Total Environ       Date:  2020-09-10       Impact factor: 7.963

9.  How does breathing frequency affect the performance of an N95 filtering facepiece respirator and a surgical mask against surrogates of viral particles?

Authors:  Xinjian He; Tiina Reponen; Roy McKay; Sergey A Grinshpun
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

10.  A Rapidly Deployable Test Suite for Respiratory Protective Devices in the COVID-19 Pandemic.

Authors:  Thijs Blad; Joep Nijssen; Freek Broeren; Bob Boogaard; Stefan Lampaert; Stefan van den Toorn; John van den Dobbelsteen
Journal:  Appl Biosaf       Date:  2020-10-08
View more