Literature DB >> 14636899

Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation.

Maros Ferencik1, Fabian Moselewski, Dieter Ropers, Udo Hoffmann, Ulrich Baum, Katharina Anders, Eugene V Pomerantsev, Suhny Abbara, Thomas J Brady, Stephan Achenbach.   

Abstract

Multidetector computed tomography (MDCT) permits visualization of the coronary arteries, but limited spatial and temporal resolution can lead to artifacts. We quantitatively evaluated the image quality that can be obtained with the latest generation of MDCT scanners with submillimeter collimation and increased gantry rotation speed. Thirty patients with angiographically proved absence of significant coronary artery stenoses (mean age 56 +/- 13 years, mean heart rate 62 +/- 13 beats/min) were studied by MDCT (12 x 0.75 mm collimation, 420-ms tube rotation, 210-ms temporal resolution, 500 mA, 120 kVp, retrospective electrocardiographic gating). In multiplanar reconstructions of the 4 major coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery), the overall visualized vessel length and the length of segments without motion artifacts were measured. Vessel diameters at 8 predefined locations were measured in MDCT maximum intensity projections and in corresponding invasive angiograms. The mean lengths of visualized coronary arteries were left main 13 +/- 6 mm, left anterior descending 138 +/- 39 mm, left circumflex 84 +/- 34 mm, and right coronary artery 155 +/- 41 mm. On average, 93 +/- 13% of the total visualized vessel length was depicted without motion artifacts (left main 100 +/- 0%, left anterior descending 93 +/- 12%, left circumflex 91 +/- 17%, and right coronary artery 87 +/- 14%). The percentage of vessel length visualized free of motion artifacts was significantly higher in patients with a heart rate </=60 beats/min compared with patients with a heart rate >60 beats/min (96 +/- 8% vs 89 +/- 17%, p <0.05). Vessel diameters in MDCT correlated closely to quantitative coronary angiography (R(2) 0.83 to 0.87). In conclusion, MDCT with submillimeter collimation and improved temporal resolution permits reliable visualization of the vessel lumen and accurate measurements of vessel dimensions.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14636899     DOI: 10.1016/j.amjcard.2003.08.003

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

1.  Efficacy of Coronary Computed Tomography Angiography for the De Novo Detection of Chronic Total Occlusion Prior to Coronary Angiography: A Preliminary and Retrospective Study.

Authors:  Dae Hyun Lee; S Kambhampati; M Mohammed; R Goli; D Thiemann; B Lawson; J Resar; B Mohanty
Journal:  Int J Angiol       Date:  2020-09-20

2.  Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors.

Authors:  Masatomo Kuwabara; Yoshifumi Narumi; Satoru Takahashi; Yoshinobu Sato; Tonsok Kim; Takamichi Murakami; Hironobu Nakamura
Journal:  Radiat Med       Date:  2006-04

3.  Detection of a double right coronary artery with 16-row multidetector computed tomography.

Authors:  Stefan P Lemburg; Soeren A Peters; Michael Scheeler; Volkmar Nicolas; Christoph M Heyer
Journal:  Int J Cardiovasc Imaging       Date:  2006-08-22       Impact factor: 2.357

Review 4.  Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography.

Authors:  D Schnapauff; F Teige; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

5.  Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography.

Authors:  Christof Burgstahler; Anja Reimann; Harald Brodoefel; Ulrike Daferner; Tina Herberts; Ilias Tsiflikas; Christoph Thomas; Tanja Drosch; Stephen Schroeder; Martin Heuschmid
Journal:  Eur Radiol       Date:  2008-10-25       Impact factor: 5.315

6.  Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography.

Authors:  L H Piers; J Dorgelo; R A Tio; G A J Jessurun; M Oudkerk; F Zijlstra
Journal:  Int J Cardiovasc Imaging       Date:  2005-08       Impact factor: 2.357

7.  Coronary vessel visualization using true 16-row multi-slice computed tomography technology.

Authors:  Axel Kuettner; Christof Burgstahler; Torsten Beck; Tanja Drosch; Andreas F Kopp; Martin Heuschmid; Claus D Claussen; Stephen Schroeder
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

Review 8.  Role of coronary artery calcium score and coronary CT angiography in the diagnosis and risk stratification of individuals with suspected coronary artery disease.

Authors:  Sean R Wilson; Fay Y Lin; James K Min
Journal:  Curr Cardiol Rep       Date:  2011-08       Impact factor: 2.931

9.  Prospectively ECG-triggered high-pitch spiral acquisition for cardiac CT angiography in routine clinical practice: initial results.

Authors:  Patric Kröpil; Carlos A Rojas; Brian Ghoshhajra; Rotem S Lanzman; Falk R Miese; Axel Scherer; Mannudeep Kalra; Suhny Abbara
Journal:  J Thorac Imaging       Date:  2012-05       Impact factor: 3.000

10.  Feasibility and diagnostic accuracy of 16-slice multidetector computed tomography coronary angiography in 500 consecutive patients: critical role of heart rate.

Authors:  Daniele Andreini; Gianluca Pontone; Giovanni Ballerini; Carlo Quaglia; Enrica Nobili; Alessandra Magini; Erika Bertella; Mauro Pepi
Journal:  Int J Cardiovasc Imaging       Date:  2007-03-15       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.