Literature DB >> 16875307

Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors.

Masatomo Kuwabara1, Yoshifumi Narumi, Satoru Takahashi, Yoshinobu Sato, Tonsok Kim, Takamichi Murakami, Hironobu Nakamura.   

Abstract

PURPOSE: The aim of this study was to evaluate the correlation between the renal artery cross-sectional area measured by multidetector computed tomography (MDCT) and the nephrogram area calculated by renal arteriography in potential living renal donors with duplicated renal arteries.
MATERIALS AND METHODS: Medical records of 18 patients with duplicated renal arteries who underwent both MDCT angiography and renal arteriography between 2001 and 2003 were retrospectively reviewed. All 20 kidneys were evaluated. Renal artery cross-sectional areas were measured using the workstation to which the CT data were transferred; the nephrogram areas on the digitized angiographic images were calculated using public domain software. Bland-Altman analysis was performed to compare the cross-sectional area ratio of the accessory arteries to the main renal arteries, with the ratios obtained from the nephrogram areas calculated from the arteriograms.
RESULTS: The mean cross-sectional areas of the accessory and main renal arteries were 6.78 and 20.9 mm2, respectively. The ratio of the nephrogram areas calculated from the arteriograms ranged from 0.094 to 0.809. Bland-Altman analysis showed no significant difference.
CONCLUSION: It is possible to predict the supply volume of accessory renal arteries by measuring the cross-sectional area of the accessory and main renal arteries in potential living renal donors.

Entities:  

Mesh:

Year:  2006        PMID: 16875307     DOI: 10.1007/s11604-005-1544-y

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  21 in total

Review 1.  Evaluation of prospective living renal donors for laparoscopic nephrectomy with multisection CT: the marriage of minimally invasive imaging with minimally invasive surgery.

Authors:  J Rydberg; K K Kopecky; M Tann; S A Persohn; S B Leapman; R S Filo; A L Shalhav
Journal:  Radiographics       Date:  2001-10       Impact factor: 5.333

2.  Living-related donors with bilateral multiple renal arteries. A twenty-year experience.

Authors:  A M Roza; L J Perloff; A Naji; R A Grossman; C F Barker
Journal:  Transplantation       Date:  1989-02       Impact factor: 4.939

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.

Authors:  G D Rubin; M D Dake; S A Napel; C H McDonnell; R B Jeffrey
Journal:  Radiology       Date:  1993-01       Impact factor: 11.105

5.  Potential renal donors: comparison of conventional imaging with helical CT.

Authors:  J F Platt; J H Ellis; M Korobkin; K A Reige; J W Konnak; A B Leichtman
Journal:  Radiology       Date:  1996-02       Impact factor: 11.105

6.  Management of multiple arteries in renal transplantation.

Authors:  K S Ganesan; A K Huilgol; S Sundar; V Chandrashekar; S Prasad; K G Raviraj
Journal:  Transplant Proc       Date:  1994-08       Impact factor: 1.066

7.  Living donor kidneys: usefulness of multi-detector row CT for comprehensive evaluation.

Authors:  Jeong-Kon Kim; Soo-Youn Park; Heon-Joon Kim; Chung-Soo Kim; Han-Jong Ahn; Tae-Young Ahn; Kyoung-Sik Cho
Journal:  Radiology       Date:  2003-10-30       Impact factor: 11.105

8.  Vascular complications after live donor renal transplantation: study of risk factors and effects on graft and patient survival.

Authors:  Yasser Osman; Ahmed Shokeir; Bedeir Ali-el-Dein; Mohamed Tantawy; Ehab W Wafa; Ahmed B Shehab el-Dein; Mohamed A Ghoneim
Journal:  J Urol       Date:  2003-03       Impact factor: 7.450

9.  Helical CT examination of potential kidney donors.

Authors:  A H Dachman; G M Newmark; M T Mitchell; E S Woodle
Journal:  AJR Am J Roentgenol       Date:  1998-07       Impact factor: 3.959

10.  Renal arterial stenoses: spiral CT angiography.

Authors:  M Galanski; M Prokop; A Chavan; C M Schaefer; K Jandeleit; J E Nischelsky
Journal:  Radiology       Date:  1993-10       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.