Literature DB >> 18953544

Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography.

Christof Burgstahler1, Anja Reimann, Harald Brodoefel, Ulrike Daferner, Tina Herberts, Ilias Tsiflikas, Christoph Thomas, Tanja Drosch, Stephen Schroeder, Martin Heuschmid.   

Abstract

Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n = 90; Siemens Sensation 64: n = 91; Siemens Definition: n = 75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347 +/- 13 vs. 254 +/- 14 (64-MSCT) vs. 233 +/- 11 (16-MSCT) HU], LM (362 +/- 11/275 +/- 12/262 +/- 9), LAD (332 +/- 17/248 +/- 19/219 +/- 14) and LCX (310 +/- 12/210 +/- 13/221 +/- 10, all p < 0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p < 0.05). BMI had no impact on the CA ratio in DSCT only (p < 0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a positive impact on the diagnostic accuracy.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18953544     DOI: 10.1007/s00330-008-1201-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography.

Authors:  Mariko Ehara; Jean-Francois Surmely; Masato Kawai; Osamu Katoh; Tetsuo Matsubara; Mitsuyasu Terashima; Etsuo Tsuchikane; Yoshihisa Kinoshita; Tomomichi Suzuki; Tatsuya Ito; Yoshihiro Takeda; Kenya Nasu; Nobuyoshi Tanaka; Akira Murata; Yasuyuki Suzuki; Koyo Sato; Takahiko Suzuki
Journal:  Circ J       Date:  2006-05       Impact factor: 2.993

2.  Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation.

Authors:  Maros Ferencik; Fabian Moselewski; Dieter Ropers; Udo Hoffmann; Ulrich Baum; Katharina Anders; Eugene V Pomerantsev; Suhny Abbara; Thomas J Brady; Stephan Achenbach
Journal:  Am J Cardiol       Date:  2003-12-01       Impact factor: 2.778

3.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

4.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

5.  Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries.

Authors:  Maros Ferencik; Cesar H Nomura; Pal Maurovich-Horvat; Udo Hoffmann; Antonio J Pena; Ricardo C Cury; Suhny Abbara; Koen Nieman; Umaima Fatima; Stephan Achenbach; Thomas J Brady
Journal:  Eur J Radiol       Date:  2006-01-24       Impact factor: 3.528

6.  Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality.

Authors:  Sebastian Leschka; Simon Wildermuth; Thomas Boehm; Lotus Desbiolles; Lars Husmann; André Plass; Pascal Koepfli; Tiziano Schepis; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Radiology       Date:  2006-09-11       Impact factor: 11.105

7.  Accuracy of MSCT coronary angiography with 64-slice technology: first experience.

Authors:  Sebastian Leschka; Hatem Alkadhi; André Plass; Lotus Desbiolles; Jürg Grünenfelder; Borut Marincek; Simon Wildermuth
Journal:  Eur Heart J       Date:  2005-04-19       Impact factor: 29.983

8.  Noninvasive coronary angiography with multislice computed tomography.

Authors:  Martin H K Hoffmann; Heshui Shi; Bernd L Schmitz; Florian T Schmid; Michael Lieberknecht; Ralph Schulze; Bernd Ludwig; Ulf Kroschel; Norbert Jahnke; Winfried Haerer; Hans-Juergen Brambs; Andrik J Aschoff
Journal:  JAMA       Date:  2005-05-25       Impact factor: 56.272

9.  Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates.

Authors:  H Brodoefel; A Reimann; M Heuschmid; A Küttner; T Beck; C Burgstahler; C D Claussen; S Schroeder; A F Kopp
Journal:  Eur Radiol       Date:  2006-02-24       Impact factor: 5.315

10.  Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results.

Authors:  Axel Kuettner; Tobias Trabold; Stephen Schroeder; Anja Feyer; Torsten Beck; Ariane Brueckner; Martin Heuschmid; Christof Burgstahler; Andreas F Kopp; Claus D Claussen
Journal:  J Am Coll Cardiol       Date:  2004-09-15       Impact factor: 24.094

View more
  6 in total

1.  Dual source computed tomography: automated, visual or dual analysis?

Authors:  E E van der Wall; J H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2008-11-27       Impact factor: 2.357

2.  Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch.

Authors:  Matthias S May; Paul Deak; Axel Kuettner; Michael M Lell; Wolfgang Wuest; Michael Scharf; Andrea K Keller; Lothar Häberle; Stephan Achenbach; Martin Seltmann; Michael Uder; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

3.  128-Slice dual source coronary CTA: defining optimal arterial enhancement levels.

Authors:  Ashkan A Malayeri; Stefan L Zimmerman; Spencer T Lake; Elliot K Fishman; Pamela T Johnson
Journal:  Emerg Radiol       Date:  2014-04-04

4.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

5.  The diagnostic accuracy, image quality and radiation dose of 64-slice dual-source CT in daily practice: a single institution's experience.

Authors:  Joon Ho Moon; Eun-Ah Park; Whal Lee; Yong Hu Yin; Jin Wook Chung; Jae Hyung Park; Hae-Young Lee; Hyun-Jae Kang; Hyo-Soo Kim
Journal:  Korean J Radiol       Date:  2011-04-25       Impact factor: 3.500

6.  Ultrafast imaging of the entire chest without ECG synchronisation or beta-blockade: to what extent can we analyse the coronary arteries?

Authors:  Maxime de Malherbe; Alain Duhamel; Nunzia Tacelli; Anne-Lise Hachulla; François Pontana; Jean-Baptiste Faivre; Jacques Remy; Martine Remy-Jardin
Journal:  Insights Imaging       Date:  2011-11-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.