PURPOSE: To evaluate the feasibility and diagnostic accuracy of multidetector computed tomography coronary (MDCT) angiography applied to an unselected heart-disease population, to identify all causes of unfeasibility of exams, the distribution of artifacts in every coronary segment and their influence on diagnostic accuracy of examination. MATERIALS AND METHODS: We evaluated 500 patients with different indications for invasive coronary angiography. All underwent coronary MDCT and ICA. 215 patients were pre-treated with metoprolol intravenously. In the whole population we studied native coronary arteries and in 141 cases the patency of coronary artery bypass grafts (CABG). The quality of MDCT images was graded as good, sufficient and insufficient. RESULTS: We were able to evaluate the patency of all grafts, with the exception of 4 cases. Diagnostic accuracy of CABG evaluation was very high (sensitivity 100%, specificity 98.4%). In native coronary arteries the overall feasibility was 97.9%. The middle left circumflex artery, right coronary artery and posterior descending artery were the segments most often poorly visualized. The first cause of artifacts was misalignment related to high heart rate, followed by premature heart beats and calcified plaque. The population was separated into 3 groups: group 1: heart rate <55 bpm, group 2: 55-65 bpm, group 3: >65 bpm. In group 1, misalignment was significantly lower than in groups 2 and 3. On a segment-based analysis, overall feasibility was therefore significantly higher in group 1 vs group 2 and vs group 3. Images of good quality were significantly higher in group 1 (95.4%) than in group 2 (87%) and group 3 (71.8%). The higher image quality in group 1 impacts on the overall diagnostic accuracy of the exam. Indeed overall sensitivity is significantly higher in group 1 (89.5%) than in group 2 (86%) and group 3 (82.8%) and overall specificity is significantly higher in group 1 than in group 3. CONCLUSIONS: Multidetector computed tomography has a high feasibility and diagnostic accuracy for the evaluation of coronary artery disease in an unselected population. Good patient preparation (optimized beta-blocker therapy, correct breathing instructions) is essential for evaluating native coronary arteries while preparation with a beta-blocker is less relevant in bypass graft patients.
PURPOSE: To evaluate the feasibility and diagnostic accuracy of multidetector computed tomography coronary (MDCT) angiography applied to an unselected heart-disease population, to identify all causes of unfeasibility of exams, the distribution of artifacts in every coronary segment and their influence on diagnostic accuracy of examination. MATERIALS AND METHODS: We evaluated 500 patients with different indications for invasive coronary angiography. All underwent coronary MDCT and ICA. 215 patients were pre-treated with metoprolol intravenously. In the whole population we studied native coronary arteries and in 141 cases the patency of coronary artery bypass grafts (CABG). The quality of MDCT images was graded as good, sufficient and insufficient. RESULTS: We were able to evaluate the patency of all grafts, with the exception of 4 cases. Diagnostic accuracy of CABG evaluation was very high (sensitivity 100%, specificity 98.4%). In native coronary arteries the overall feasibility was 97.9%. The middle left circumflex artery, right coronary artery and posterior descending artery were the segments most often poorly visualized. The first cause of artifacts was misalignment related to high heart rate, followed by premature heart beats and calcified plaque. The population was separated into 3 groups: group 1: heart rate <55 bpm, group 2: 55-65 bpm, group 3: >65 bpm. In group 1, misalignment was significantly lower than in groups 2 and 3. On a segment-based analysis, overall feasibility was therefore significantly higher in group 1 vs group 2 and vs group 3. Images of good quality were significantly higher in group 1 (95.4%) than in group 2 (87%) and group 3 (71.8%). The higher image quality in group 1 impacts on the overall diagnostic accuracy of the exam. Indeed overall sensitivity is significantly higher in group 1 (89.5%) than in group 2 (86%) and group 3 (82.8%) and overall specificity is significantly higher in group 1 than in group 3. CONCLUSIONS: Multidetector computed tomography has a high feasibility and diagnostic accuracy for the evaluation of coronary artery disease in an unselected population. Good patient preparation (optimized beta-blocker therapy, correct breathing instructions) is essential for evaluating native coronary arteries while preparation with a beta-blocker is less relevant in bypass graft patients.
Authors: T M Bashore; E R Bates; P B Berger; D A Clark; J T Cusma; G J Dehmer; M J Kern; W K Laskey; M P O'Laughlin; S Oesterle; J J Popma; R A O'Rourke; J Abrams; E R Bates; B R Brodie; P S Douglas; G Gregoratos; M A Hlatky; J S Hochman; S Kaul; C M Tracy; D D Waters; W L Winters Journal: J Am Coll Cardiol Date: 2001-06-15 Impact factor: 24.094
Authors: P J Scanlon; D P Faxon; A M Audet; B Carabello; G J Dehmer; K A Eagle; R D Legako; D F Leon; J A Murray; S E Nissen; C J Pepine; R M Watson; J L Ritchie; R J Gibbons; M D Cheitlin; T J Gardner; A Garson; R O Russell; T J Ryan; S C Smith Journal: J Am Coll Cardiol Date: 1999-05 Impact factor: 24.094
Authors: W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe Journal: Circulation Date: 1975-04 Impact factor: 29.690
Authors: Liesbeth P Salm; Jeroen J Bax; J Wouter Jukema; Joanne D Schuijf; Hubert W Vliegen; Hildo J Lamb; Ernst E van der Wall; Albert de Roos Journal: Am Heart J Date: 2005-10 Impact factor: 4.749
Authors: Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders Journal: Eur J Radiol Date: 2006-01-19 Impact factor: 3.528
Authors: Stephen Schroeder; Andreas F Kopp; Axel Kuettner; Christof Burgstahler; Christian Herdeg; Martin Heuschmid; Andreas Baumbach; Claus D Claussen; Karl R Karsch; Ludger Seipel Journal: Clin Imaging Date: 2002 Mar-Apr Impact factor: 1.605
Authors: Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach Journal: Circulation Date: 2003-02-11 Impact factor: 29.690
Authors: Gianluca Pontone; Daniele Andreini; Erika Bertella; Andrea Baggiano; Saima Mushtaq; Monica Loguercio; Chiara Segurini; Edoardo Conte; Virginia Beltrama; Andrea Annoni; Alberto Formenti; Maria Petullà; Andrea I Guaricci; Piero Montorsi; Daniela Trabattoni; Antonio L Bartorelli; Mauro Pepi Journal: Eur Radiol Date: 2015-05-09 Impact factor: 5.315