Literature DB >> 14618365

Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement.

K Eklund1, K Jonsson, G Lindblom, B Lundin, J Sanfridsson, M Sloth, B Sivberg.   

Abstract

The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, kappa(w), analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied kappa(w) 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied kappa(w) of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses.

Entities:  

Mesh:

Year:  2003        PMID: 14618365     DOI: 10.1007/s00330-003-2126-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  15 in total

1.  Simulated bone erosions in a hand phantom: detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector.

Authors:  M Strotzer; M Völk; T Wild; P von Landenberg; S Feuerbach
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

2.  Evaluation of radiolucency condition in total hip arthroplasty: a statistical comparison of the diagnostic capability of digitised image vs. conventional X-ray film.

Authors:  M Testoni; F Baruffaldi; P Mattioli; A Sudanese; S Terzi; G Barbanti-Brodano; A Toni
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

3.  Can we see enough? A comparative study of film-screen vs digital radiographs in small lesions in rheumatoid arthritis.

Authors:  E J van der Jagt; S Hofman; B M Kraft; M A van Leeuwen
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

4.  Digital radiography with a large-scale electronic flat-panel detector vs. screen-film radiography: observer preference in clinical skeletal diagnostics.

Authors:  S Hamers; J Freyschmidt; U Neitzel
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

5.  Detection of porcine bone lesions and fissures: comparing digital selenium, digital luminescence, and analog film-screen radiography.

Authors:  M Zähringer; B Krug; K F Kamm; G Wassmer; M Hellmich; G Winnekendonk; J Andermahr; A Gossmann; K J Lackner
Journal:  AJR Am J Roentgenol       Date:  2001-12       Impact factor: 3.959

6.  Computed vs. film-screen magnification radiography of fingers in hyperparathyroidism. An ROC analysis.

Authors:  A Jónsson; P Hannesson; K Herrlin; K Jonsson; R Andersen; H Pettersson
Journal:  Acta Radiol       Date:  1995-05       Impact factor: 1.990

7.  Film-screen vs. digital radiography in rheumatoid arthritis of the hand. An ROC analysis.

Authors:  A Jónsson; A Borg; P Hannesson; K Herrlin; K Jonsson; M Sloth; H Petterson
Journal:  Acta Radiol       Date:  1994-07       Impact factor: 1.990

8.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

9.  Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: a subjective comparison.

Authors:  D W Piraino; W J Davros; M Lieber; B J Richmond; J P Schils; M P Recht; P N Grooff; G H Belhobek
Journal:  AJR Am J Roentgenol       Date:  1999-01       Impact factor: 3.959

10.  Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

Authors:  H J Langen; H M Klein; B Wein; A Stargardt; R W Günther
Journal:  Invest Radiol       Date:  1993-08       Impact factor: 6.016

View more
  4 in total

1.  Evaluation of lower limb axial alignment using digital radiography stitched films in pre-operative planning for total knee replacement.

Authors:  Michael J Neil; Jereme B Atupan; Juan Paulo L Panti; Robert A J Massera; Stewart Howard
Journal:  J Orthop       Date:  2016-06-29

2.  Comparison of radiographs, tomosynthesis and CT with metal artifact reduction for the detection of hip prosthetic loosening.

Authors:  Romain Gillet; Pedro Teixeira; Chloé Bonarelli; Henry Coudane; François Sirveaux; Mathias Louis; Alain Blum
Journal:  Eur Radiol       Date:  2018-09-07       Impact factor: 5.315

3.  Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS).

Authors:  Kyu Yeol Lee; Sung Soo Kim; Hyeon Jun Kim; Dong Ho Ha; Hyung Min Yoon; Hyun Su Do
Journal:  Hip Pelvis       Date:  2015-03-31

4.  Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs.

Authors:  J Sailer; M Scharitzer; P Peloschek; A Giurea; H Imhof; S Grampp
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.